Free flow isotachophoresis in an injection moulded miniaturised separation chamber with integrated electrodes.

An injection moulded free flow isotachophoresis (FFITP) microdevice with integrated carbon fibre loaded electrodes with a separation chamber of 36.4mm wide, 28.7 mm long and 100 microm deep is presented. The microdevice was completely fabricated by injection moulding in carbon fibre loaded polystyrene for the electrodes and crystal polystyrene for the remainder of the chip and was bonded together using ultrasonic welding. Two injection moulded electrode designs were compared, one with the electrode surface level with the separation chamber and one with a recessed electrode. Separations of two anionic dyes, 0.2mM each of amaranth and acid green and separations of 0.2mM each of amaranth, bromophenol blue and glutamate were performed on the microdevice. Flow rates of 1.25 ml min(-1) for the leading and terminating electrolytes were used and a flow rate of 0.63 ml min(-1) for the sample. Electric fields of up to 370 V cm(-1) were applied across the separation chamber. Joule heating was not found to be significant although out-gassing was observed at drive currents greater than 3 mA.

Electrodes↗

Rapid chloride analysis using miniaturised isotachophoresis.

A new design of miniaturised separation device for performing isotachophoresis (ITP) has been produced. The device contains a simple arrangement of channels comprising a single separation channel with a 'double T' injection geometry. The device was produced in poly(methyl methacrylate) and incorporates an on-column conductivity detector. A new electrolyte system was developed to enable the rapid determination of chloride to be made. This electrolyte system uses a leading ion of 3.5 mM nitrate at pH 3.0 with 0.5 mM indium(III) added as a complexing agent. Use of this electrolyte system with the new separation device allowed chloride samples to be analysed in under 100 s, with a limit of detection (LOD) calculated to be 2.2 mg l(-1).

Chlorides↗

An integrated optical leaky waveguide sensor with electrically induced concentration system for the detection of bacteria.

An integrated, sensitive and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor with an electric field. The electric field was used to concentrate Bacillus subtilis var. niger(BG) bacteria spores onto the immobilized anti-BG antibody on the MCLW sensor surface. This sensor combination has been characterised by detecting the scattering from bacterial spores, which are concentrated at the sensor surface, when they are illuminated at the coupling angle; and by detection of fluorescence from labelled antibodies added after the spores had been captured on the surface. The light scattering and fluorescence detection methods gave a detection limit of BG bacterial spores of 1 x 10(3) spores ml(-1) when the electric field was applied for 3 minutes.

Bacillus subtilis↗

Optical leaky waveguide sensor for detection of bacteria with ultrasound attractor force.

An integrated, sensitive, and rapid system was developed for the detection of bacteria. The system combined an optical metal-clad leaky waveguide (MCLW) sensor with ultrasound standing waves (USW). The performance of a MCLW sensor for the detection of bacteria has been increased (>100 fold) by using USWs to drive bacteria onto the sensor surface. By forming the USW nodes at or within the surface of the MCLW, the diffusion-limited capture rate has been replaced by fast movement. Immobilized anti-BG antibody on the MCLW sensor surface was used to capture Bacillus subtilis var. niger (BG) bacterial spores driven to the surface. This combination of sensor and attractor force combination has been tested by detecting the evanescent scattering from bacterial spores at the sensor surface. Application of ultrasound for 3 min gave a detection limit for BG bacterial spores of 1 x 10(3) spores/mL.

Bacillus subtilis↗

Analysis of chloride, bromide and iodide using miniaturised isotachophoresis on a planar polymer chip.

A new method has been developed to allow the determination of the halide anions chloride, bromide and iodide using isotachophoresis. This method employs a new electrolyte system which incorporates the novel application of indium(III) as a complexing agent. This electrolyte system was devised based on the findings of an investigation into the potential for using indium(III) as a complexing counter ion to selectively manipulate the effective mobilities of halide ions. A leading electrolyte incorporating 3.5 mmol dm(-3) of indium(III) allowed the simultaneous determination of chloride, bromide and iodide to be successfully achieved. The new procedure allows such separations to be made without interference from common inorganic anions such as sulfate and nitrate. Separations were performed using a miniaturised planar poly(methyl methacrylate) chip with integrated platinum wire conductivity detection electrodes. Using this instrumentation the limits of detection were calculated to be 0.7 mg dm(-3), 1.7 mg dm(-3) and 2.2 mg dm(-3) for chloride, bromide and iodide respectively.

Anions↗

An integrated metal clad leaky waveguide sensor for detection of bacteria.

An integrated optical metal clad leaky waveguide (MCLW) sensor device has been developed for the detection of bacteria. This is more sensitive than waveguide sensors currently in use. The MCLW device has been fabricated to extend the evanescent field to provide significant light intensity over the entire volume of the bacteria bound on the chip surface within this field. This in turn increases the interaction of the light with the entire volume of the bacteria. MCLW devices have been used for detecting refractive index changes, scattering, and fluorescence from bacterial spores captured on an immobilized antibody. The detection limit of Bacillus subtilis var. niger bacterial spores using refractive index detection was 8 x10(4) spores/mL. The scattering intensity of the BG spores was found to be three times greater than the scattering intensity generated using surface plasmon resonance. The extended light propagation along the direction of flow for a few millimeters provides an effective interrogation approach to increase the area of detection to detect low concentrations down to 1 x 10(4) spores/mL. The sensor was then optimized by studying the key factors affecting sensor performance including changing the pH of the medium, type of antibody immobilization matrix, sensor surface regeneration approaches, and longevity of the sensor.

Bacteria↗

Bacteria detection using disposable optical leaky waveguide sensors.

Novel disposable absorbing material clad leaky waveguide sensor devices (LWD) have been developed for the detection of pathogenic particles such as bacteria. These chips are tailored to give the maximum extension of the evanescent field at the sensor surface in order to place the entire volume of the bacteria captured by immobilized antibodies on the chip surface within this field. This in turn increases the interaction of the light with the bacteria's bulk volume. Disposable LWD chips were fabricated at room temperature and without the use of expensive fabrication equipment. These LWDs have been characterised by detecting refractive index (RI) changes, scattering and fluorescence from bacterial spores at the sensor surface when illuminated at the coupling angle. The detection limit of Bacillus subtilis var. niger (BG) bacterial spores was 10(4) spores/ml and the illumination intensity of the spores was found to be three times greater than the illumination intensity generated using the surface plasmon resonance (SPR).

Bacillus↗

Analysis of amino acids by miniaturised isotachophoresis.

A method allowing the miniaturised isotachophoretic analysis of amino acids has been developed. To overcome the problems of carbonate contamination which occur when performing separations at alkaline pH levels glycolate was used as the leading ion. Addition of magnesium to the leading electrolyte as a counter species was found to improve the separations. The method has been used on a poly(methyl methacrylate) microdevice with integrated on-column conductivity detectors. The behaviour of a range of common amino acids was investigated and successful separations of up to seven amino acids were made. Good linearity was observed with calibration curves for aspartic acid and phenylalanine over the range 0.063-1.0 mM. Limits of detection for these two species were calculated to be 0.060 and 0.018 mM, respectively.

Amino Acid Sequence↗

Use of miniaturised isotachophoresis on a planar polymer chip to analyse transition metal ions in solutions from metal processing plants.

An electrolyte system, using malic acid as a complexing agent, has been developed to allow the determination of transition metal cations using miniaturised isotachophoresis. The method allowed the simultaneous determination of Mn2+, Cr3+, Fe2+, Co2+, Zn2+ and Ni2+ to be made without interference from other common ions. Limits of detection were calculated to be in the range 0.5-1.0mg l(-1) for Mn2+, Cr3+ Co2+ and Zn2+ and 2.0 mg l(-1) for Fe2+ and 4.7 mg l(-1) for Ni2+. The successful analysis of five industrial samples, containing a range of these metal ions, obtained from metal processing plants were achieved in under 13 min. The separations were performed on a poly(methyl methacrylate) chip with integrated platinum wire conductivity detection electrodes.

Electrophoresis↗

Water toxicity monitoring using Vibrio fischeri: a method free of interferences from colour and turbidity.

In this paper the kinetic method for the determination of toxicity using Vibrio fischeri is described and suggested as a potential method for the continuous screening of wastewater toxicity. The kinetic method was demonstrated to be free from interferences due to colour and turbidity normally observed when testing wastewater samples with this organism. This is of great importance for the application of the method to remote toxicity screening of wastewaters. The effect of colour, investigated using 50 ppm Zn(2+) solutions containing the food-dye tropaeolin O, and the effect of turbidity, investigated using 50 ppm Zn(2+) solutions containing white optically reflective and coloured optically absorbing polystyrene beads, is reported. It was also found that the design of the light detection system of the instrument ensures efficient collection of the light scattered by particles in the sample, which enables a greater range of turbid samples to be tested. In addition the natural light decay was found to be negligible during the duration of a 10 min test and thus one channel would be enough to carry out the tests. This would mean halving the quantity of bacterial reagent used and reducing the cost of the tests.

Color↗

Determination of inorganic selenium species by miniaturised isotachophoresis on a planar polymer chip.

The use of miniaturised isotachophoresis to allow the simultaneous determination of two inorganic selenium species has been investigated using a poly(methyl methacrylate) chip with a 44-mm-long, 200-microm-wide, 300-microm-deep separation channel. The miniaturised device included an integrated on-column, dual-electrode conductivity detector and was used in conjunction with a hydrodynamic fluid transport system. A simple electrolyte system has been developed which allowed the separation of selenium(IV) and selenium(VI) species to be made in under 210 s. The limits of detection were calculated to be 0.52 mg L(-1) for selenium(IV) and 0.65 mg L(-1 )for selenium(VI). The method allowed the separation of the selenium species from a range of common anions including fluoride, nitrate, nitrite, phosphate, sulfate and sulfite.

Journal Article↗

Miniaturised isotachophoretic analysis of inorganic arsenic speciation using a planar polymer chip with integrated conductivity detection.

A new method allowing the analysis of inorganic arsenic species using isotachophoresis has been developed. This method has been shown to be suitable for use on both miniaturised planar polymer separation devices and capillary scale devices. A poly(methyl methacrylate) chip with integrated conductivity electrodes has been successfully used for the rapid analysis of inorganic arsenic species in under 600 s. Limits of detection of 1.8 mg l(-1) and 4.8 mg l(-1) for arsenic(V) and arsenic(II), respectively, have been achieved with the miniaturised device. The device has also been used to perform the simultaneous separation of arsenic(III), arsenic(V), antimony(III), molybdenum(VI) and tellurium(IV).

Electric Conductivity↗

Determination of the ascorbate content of photographic developer solutions using miniaturised isotachophoresis on a planar chip.

The use of miniaturised isotachophoresis, performed on a planar poly(methyl methacrylate) device with integrated platinum conductivity electrodes, for the analysis of the ascorbate content of photographic developer solutions has been investigated. An electrolyte system has been developed which enabled the analysis to be made without interference from any of the other components in the developer solution, a number of which were present at significantly higher concentrations than that of the ascorbate ions. Using this system, the ascorbate content of the developer solutions could be analysed in under 6 min. The limit of detection for ascorbate using miniaturised isotachophoresis was calculated to be 0.011 mmol dm(-3).

Journal Article↗

Bidirectional isotachophoresis on a planar chip with integrated conductivity detection.

The use of a miniaturised planar separation device with integrated conductivity detection for performing bidirectional isotachophoresis (ITP) is described. The chips were produced in poly(methyl methacrylate) (PMMA) using a milling procedure. To enable bidirectional ITP the devices were designed to inject samples into the centre of the section channel and incorporated two integrated on-column conductivity detectors, positioned at opposite ends of this channel. When used with a hydrodynamic sample transport system the devices were used for the analysis of a range of small ions: NH4+; Na+; Mg2+; Ca2+; Li+; NO3-; ClO4-; SO4(2-); F-. Results sucessfully achieved included the simultaneous separation of three anions and three cations.

Journal Article↗