UNLABELLED: The aim of this study was to validate Quantitative Gated SPECT (QGS) and 4D-MSPECT for assessing left ventricular end-diastolic and systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF) from gated (18)F-FDG PET. METHODS: Forty-four patients with severe coronary artery disease were examined with gated (18)F-FDG PET (8 gates per cardiac cycle). EDV, ESV, and LVEF were calculated from gated (18)F-FDG PET using QGS and 4D-MSPECT. Within 2 d (median), cardiovascular cine MRI (cMRI) (20 gates per cardiac cycle) was done as a reference. RESULTS: QGS failed to accurately detect myocardial borders in 1 patient; 4D-MSPECT, in 2 patients. For the remaining 42 patients, correlation between the results of gated (18)F-FDG PET and cMRI was high for EDV (R = 0.94 for QGS and 0.94 for 4D-MSPECT), ESV (R = 0.95 for QGS and 0.95 for 4D-MSPECT), and LVEF (R = 0.94 for QGS and 0.90 for 4D-MSPECT). QGS significantly (P < 0.0001) underestimated LVEF, whereas no other parameter differed significantly between gated (18)F-FDG PET and cMRI for either algorithm. CONCLUSION: Despite small systematic differences that, among other aspects, limit interchangeability, agreement between gated (18)F-FDG PET and cMRI is good across a wide range of clinically relevant volumes and LVEF values assessed by QGS and 4D-MSPECT.
UNLABELLED: Heterogeneous perfusion in left bundle branch block (LBBB) has been demonstrated by (99m)Tc-methoxyisobutylisonitrile (MIBI) SPECT. Locally different contraction is also associated with LBBB. Quantitative analysis of myocardial SPECT is influenced by partial-volume effects depending on systolic wall thickening. Therefore, partial-volume effects may mimic perfusion heterogeneity in LBBB. METHODS: Fifteen patients with nonischemic dilated cardiomyopathy and LBBB underwent resting (15)O-water PET, (99m)Tc-MIBI SPECT, and gated (18)F-FDG PET for analysis of wall thickening. Myocardial blood flow corrected for rate-pressure product (corrMBF), (99m)Tc-MIBI uptake, and wall thickening were determined in 4 left ventricular wall areas. In 14 patients, M-mode echocardiographic recordings were available for comparison. RESULTS: Homogeneous distribution was found for corrMBF (1.09 +/- 0.41 to 1.19 +/- 0.31 mL x g(-1) x min(-1)). (99m)Tc-MIBI uptake and wall thickening were heterogeneous (P < 0.0001), with the lowest values septal ((99m)Tc-MIBI, 65% +/- 10%; wall thickening, 16% +/- 14%) and the highest lateral ((99m)Tc-MIBI, 84% +/- 5%; wall thickening, 55% +/- 17%). Similar relationships in systolic wall thickening were observed by M-mode echocardiography (anteroseptal, 20% +/- 11%; posterolateral, 37% +/- 18%; P < 0.001). CONCLUSION: Heterogeneity of (99m)Tc-MIBI uptake in LBBB corresponds to differences in wall thickening and does not reflect distribution of corrMBF. Supplementary analysis of wall thickening is recommended when assessing (99m)Tc-MIBI SPECT in LBBB.
UNLABELLED: Although ventilation/perfusion (V/Q) lung scintigraphy is a well-accepted and frequently performed procedure in the diagnosis of pulmonary embolism, there is growing controversy about its relevance, particularly due to the increasing competition between scintigraphy and CT. Even though comparative studies between both modalities have already been performed, their results were highly inconsistent. Remarkably, in most of those studies, conventional planar perfusion scans were compared with tomographic images acquired using state-of-the-art CT scanners-a study design that cannot give impartial results. Hence, the aim of our study was a balanced comparison between V/Q lung scintigraphy and CT angiography using advanced imaging techniques for both modalities. METHODS: A total of 83 patients with suspected pulmonary embolism were examined using V/Q lung scintigraphy in SPECT technique as well as 4-slice spiral CT. Ventilation scans were done using an ultrafine aerosol. Additionally, planar images in 8 views were extracted from the V/Q SPECT datasets. Two experienced referees assessed each of the 3 modalities. The final diagnosis was made at a consensus meeting while taking into account all of the imaging modalities, laboratory tests, clinical data, and evaluation of a follow-up period. RESULTS: In the course of the consensus conference, pulmonary embolism was diagnosed in 37 of the 83 patients (44.6%). Compared with planar scintigraphy, SPECT raised the number of detectable defects at the segmental level by 12.8% (+11 defects; P = 0.401) and at the subsegmental level by 82.6% (+57 defects; P < 0.01). The sensitivity/specificity/accuracy of planar V/Q scintigraphy and V/Q SPECT was 0.76/0.85/0.81 and 0.97/0.91/0.94, respectively, compared with 0.86/0.98/0.93 for multislice CT. CONCLUSION: SPECT and ultrafine aerosols are technical advancements that can substantially improve lung scintigraphy. Using advanced imaging techniques, V/Q scintigraphy and multislice spiral CT both yield an excellent and, in all aspects, comparable diagnostic accuracy, with CT leading in specificity while SPECT shows a superior sensitivity. Even though planar lung scintigraphy yields satisfactory results for a nontomographic modality, it does not compare with tomographic imaging.
UNLABELLED: Gated myocardial perfusion SPECT allows assessment of left ventricular end-diastolic volume (EDV), left ventricular end-systolic volume (ESV), left ventricular stroke volume (SV), and left ventricular ejection fraction (LVEF). Acquiring images with the patient both prone and supine is an approved method of identifying and reducing artifacts. Yet prone positioning alters physiologic conditions. This study investigated how prone versus supine patient positioning during gated SPECT affects EDV, ESV, SV, LVEF, and heart rate. METHODS: Forty-eight patients scheduled for routine myocardial perfusion imaging were examined with gated (99m)Tc-sestamibi SPECT (at rest) while positioned prone and supine (consecutively, in random order). All parameters for both acquisitions were calculated using the commercially available QGS algorithm. RESULTS: Whereas EDV and SV were significantly lower (P < 0.0004) for prone acquisitions (EDV, 110.5 +/- 39.1 mL; SV, 55.9 +/- 13.3 mL) than for supine acquisitions (EDV, 116.9 +/- 36.2 mL; SV, 61.0 +/- 14.5 mL), ESV and LVEF did not differ significantly. Heart rate was significantly higher (P < 0.0001) during prone acquisitions (69.1 +/- 10.5 min(-1)) than during supine acquisitions (66.5 +/- 10.0 min(-1)). CONCLUSION: The observed position-dependent effect on EDV, SV, and heart rate might be explained by decreased arterial filling and increased sympathetic nerve activity. Hence, supine reference data should not be used to classify the results of prone acquisitions.
OBJECTIVES: We investigated whether cardiac resynchronization therapy (CRT) affects myocardial glucose metabolism and perfusion in dilated cardiomyopathy (DCM) and left bundle branch block (LBBB). BACKGROUND: Patients with DCM and LBBB present with asynchronous left ventricular (LV) activation, leading to reduced septal glucose metabolism. Cardiac resynchronization therapy recoordinates LV activation, but its effects on myocardial glucose metabolism and perfusion remain unknown. METHODS: In 15 patients (10 females; 61 +/- 13 years) with DCM and LBBB (QRS width 165 +/- 15 ms), gated (18)F-fluorodeoxyglucose (FDG) positron emission tomography (PET) and technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography were performed before and after two weeks of CRT. Uptake of FDG and (99m)Tc-sestamibi was determined in four LV wall areas. Ejection fraction and volumes were calculated from gated PET. RESULTS: Baseline FDG uptake was heterogeneous (p < 0.0001), with lowest uptake in the septal region (56 +/- 12%) and highest uptake in the lateral region (89 +/- 6%). During CRT, septal and anterior increases (p < 0.01) and lateral decreases (p < 0.01) resulted in homogeneously distributed glucose metabolism. Baseline heterogeneity (p < 0.0001) in (99m)Tc-sestamibi uptake was modest (lowest septal 65 +/- 10%; maximum lateral 84 +/- 5%) and also reduced with CRT, although some heterogeneity (p < 0.05) remained. The septal-to-lateral ratio increased with CRT for FDG (0.62 +/- 0.12 to 0.91 +/- 0.26, p < 0.001) and (99m)Tc-sestamibi uptake (0.77 +/- 0.13 to 0.85 +/- 0.16, p < 0.01). The LV end-diastolic and end-systolic volumes decreased from 293 +/- 160 to 272 +/- 158 ml (p < 0.05) and from 244 +/- 164 to 220 +/- 160 ml (p < 0.01), respectively. Ejection fraction increased from 22 +/- 12% to 25 +/- 13% (p < 0.01). CONCLUSIONS: Glucose metabolism is reduced more than perfusion in the septal compared with LV lateral wall in patients with DCM and LBBB. Cardiac resynchronization therapy restores homogeneous myocardial glucose metabolism with less influence on perfusion.
The aim of this study was to validate the estimation of left ventricular end-diastolic and end-systolic volumes (EDV, ESV) and ejection fraction (LVEF) as well as wall motion analysis from gated fluorine-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) in patients with severe coronary artery disease (CAD) using software originally designed for gated single-photon emission tomography (SPET). Thirty patients with severe CAD referred for myocardial viability diagnostics were investigated using a standard FDG PET protocol enhanced with gated acquisition (8 gates per cardiac cycle). EDV, ESV and LVEF were calculated using standard software designed for gated SPET (QGS). Wall motion was analysed using a visual four-point wall motion score on a 17-segment model. As a reference, all patients were also examined within a median of 3 days with cardiovascular cine magnetic resonance imaging (cMRI) (20 gates per cardiac cycle). Furthermore, all gated FDG PET data sets were reoriented in a second run with deliberately misaligned axes to test the quantification procedure for robustness. Correlation between the results of gated FDG PET and cMRI was very high for EDV and ESV ( R=0.96 and R=0.97) and for LVEF ( R=0.95). With gated FDG PET, there was a non-significant tendency to underestimate EDV (174+/-61 ml vs 179+/-59 ml, P=0.21) and to overestimate ESV (124+/-58 ml vs 122+/-60 ml, P=0.65), resulting in underestimated LVEF values (31.5%+/-9.4% vs 34.2%+/-12.4%, P<0.003). The results of reorientations 1 and 2 showed very high correlations (for all R>/=0.99). Segmental wall motion analysis revealed good agreement between gated FDG PET data and cMRI (kappa =0.62+/-0.03). In conclusion, despite small systematic differences which contributed mainly to the lower temporal resolution of gated FDG PET, agreement between gated FDG PET and cMRI was good across a wide range of volumes and LVEF values as well as for wall motion analysis. Therefore, gated FDG PET provides clinically relevant information on function and volumes, using the commercially available software package QGS.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
PURPOSE: To evaluate a self-expanding rhenium 188 (188Re) radiochemically labeled radioactive stent in sheep. MATERIALS AND METHODS: A self-expanding nitinol stent (30 mm in length, 8 mm in diameter) coated with a functionalized polymer layer was radiolabeled with 188Re. Fifty prostheses, 25 of which were radioactive (mean radioactivity, 20 MBq +/- 3.8 [SD]) and 25 of which were nonradioactive, were implanted into the external iliac arteries of 25 sheep. Stent patency was assessed with angiography. Neointimal formation was assessed with intravascular ultrasonography and histologic examination 1 month (in all sheep) and 3 months (in 12 sheep) after implantation. The results were analyzed by using repeated-measures analysis of variance with two repeated factors and paired t tests for comparison at each measuring point. RESULTS: All stents were placed successfully. Data in one animal had to be excluded from the study. After 3 months, a mean neointimal area reduction of 70 mm2 +/- 55 (SD) was observed inside the radioactive stents, and a mean lumen reduction of 126 mm2 +/- 39 was observed inside the nonradioactive control stents (P =.022). An edge effect was observed in the radioactive stents in that they showed an amount of neointimal formation at the edges that was similar to that seen in control stents. This neointimal formation accounted for the maximum lumen loss in the vascular segment with the stent. CONCLUSION: As compared with a nonradioactive stent, a beta particle-emitting stent, through endovascular irradiation, significantly inhibits neointimal formation inside the stent but not at the stent edges.
UNLABELLED: Myocardial perfusion imaging with (99m)Tc-tetrofosmin is based on the assumption of a linear correlation between myocardial blood flow (MBF) and tracer uptake. However, it is known that (99m)Tc-tetrofosmin uptake is directly related to energy-dependent transport processes, such as Na(+)/H(+) ion channel activity, as well as cellular and mitochondrial membrane potentials. Therefore, cellular alterations that affect these energy-dependent transport processes ought to influence (99m)Tc-tetrofosmin uptake independently of blood flow. Because metabolism ((18)F-FDG)-perfusion ((99m)Tc-tetrofosmin) mismatch myocardium (MPMM) reflects impaired but viable myocardium showing cellular alterations, MPMM was chosen to quantify the blood flow-independent effect of cellular alterations on (99m)Tc-tetrofosmin uptake. Therefore, we compared microsphere-equivalent MBF (MBF_micr; (15)O-water PET) and (99m)Tc-tetrofosmin uptake in MPMM and in "normal" myocardium. METHODS: Forty-two patients with severe coronary artery disease, referred for myocardial viability diagnostics, were examined using (18)F-FDG PET and (99m)Tc-tetrofosmin perfusion SPECT. Relative (18)F-FDG and (99m)Tc-tetrofosmin uptake values were calculated using 18 segments per patient. Normal myocardium and MPMM myocardium were classified using a previously validated (99m)Tc-tetrofosmin SPECT/(18)F-FDG PET score. In addition, (15)O-water PET was performed to assess kinetic-modeled MBF (MBF_kin), the water-perfusable tissue fraction (PTF), and the resulting MBF_micr (MBF_kin x PTF), which is comparable to tracer uptake values. (99m)Tc-tetrofosmin uptake and MBF_micr values were calculated for all normal and MPMM segments and averaged within their respective classifications. RESULTS: Mean relative (99m)Tc-tetrofosmin uptake was 86% +/- 1% in normal myocardium and 56% +/- 1% in MPMM, showing a significant difference (P < 0.001), as was expected from the classification. Contrary to these findings, mean MBF_micr in MPMM myocardium was 0.60 +/- 0.03 mL x min(-1) x mL(-1), which did not significantly differ from normal myocardium (0.64 +/- 0.01 mL x min(-1) x mL(-1)). All values are given as mean +/- SEM. CONCLUSION: Differences between reduced (99m)Tc-tetrofosmin uptake and the unchanged MBF_micr in MPMM myocardium suggest that the pathophysiologic basis of MPMM is not a blood flow reduction but cellular alterations that affect uptake and retention of (99m)Tc-tetrofosmin independently of blood flow. Therefore, it seems that perfusion deficits in MPMM myocardium are greatly overestimated by (99m)Tc-tetrofosmin and that it tends to give false-positive findings.
Explore the source record for details and available documents.
OBJECTIVES: This study sought to evaluate whether objective assessment of the myocardial functional reserve, using strain rate imaging (SRI), allows accurate detection of viable myocardium. BACKGROUND: Strain rate imaging is a new echocardiographic modality that allows quantitative assessment of segmental myocardial contractility. METHODS: In 37 patients (age 58 +/- 9 years) with ischemic left ventricular dysfunction, myocardial viability was assessed using low-dose (10 microg/kg body weight per min) two-dimensional dobutamine stress echocardiography (DSE), tissue Doppler imaging, SRI and (18)F-fluorodeoxyglucose ((18)FDG) positron emission tomography (PET). The peak systolic tissue Doppler velocity and peak systolic myocardial strain rate were determined at baseline and during low-dose dobutamine stress from the apical views. RESULTS: A total of 192 segments with dyssynergy at rest were classified by (18)FDG PET as viable in 94 and nonviable in 98. An increase of peak systolic strain rate from rest to dobutamine stimulation by more than -0.23 1/s allowed accurate discrimination of viable from nonviable myocardium, as determined by (18)FDG PET with a sensitivity of 83% and a specificity of 84%. Receiver operating characteristic (ROC) curve analysis showed an area under the curve for prediction of nonviable myocardium, as determined by (18)FDG PET using SRI, of 0.89 (95% confidence interval [CI] 0.88 to 0.90), whereas the area under the ROC curve using tissue Doppler imaging was 0.63 (95% CI 0.61 to 0.65). CONCLUSIONS: The increase in the peak systolic strain rate during low-dose dobutamine stimulation allows accurate discrimination between different myocardial viability states. Strain rate imaging is superior to two-dimensional DSE and tissue Doppler imaging for the assessment of myocardial viability.
Intermittent atrial undersensing is observed in a considerable percentage of patients with single lead VDD pacemakers. Analyzing the 2-year data of the Saphir Multicenter Follow-Up Study, the authors investigated predictors for the occurrence of undersensing. The study included 194 patients with high degree AV block who received a VDD pacemaker system with an identical sensing amplifier. Placement strategy of the atrial dipole was left to the discretion of the implanting physician. At the final position, atrial potential amplitudes were measured during deep and shallow respiration. Atrial dipole position was determined by intraoperativefluoroscopy subdividing the right atrium in a high, mid, and low portion. Undersensing was defined by evidence of at least one not sensed P wave during Holter monitoring or exercise testing and by the presence of 0.1-0.2 mV amplitudes in the P wave amplitude histogram of the pacemaker. Incidence of undersensing was 25.8%; 9.3% of patients showed frequent (> 5%) or symptomatic undersensing. Patients with undersensing were older (76.6 +/- 10.6 vs 64.2 +/- 14.8 years), showed a lower minimum of intraoperative atrial potential amplitude (P(min) 0.86 +/- 0.64 vs 1.43 +/- 0.77 mV), a wider range of potential amplitude (deltaP 1.71 +/- 1.44 vs 0.94 +/- 0.84 mV), and a higher incidence of dipole placement in the low right atrium (50.0% vs 11.1 %, P < 0.001 for all comparisons). In a multivariate regression analysis, patient age > 66 years, Pmin < 0.6 mV, > 1.3 mV and atrial dipol placement in the lowright atrium were independently predictive for undersensing. Minimal atrialpotential amplitude, range of potential amplitude, and atrial dipole position influence atrial sensing performance in single lead VDD pacing. Thus, implantation guidelines should reflect these rules to improve the outcome of VDD pacemaker recipients.
Stored electrograms (EGMs), well-known diagnostic tools in implantable cardioverter defibrillators, have now been incorporated in pacemakers as well, thereby increasing their diagnostic capabilities. The clinician can detect and diagnose patient arrhythmias with EGMs and directly validate diagnostic data stored by the devices. The appropriateness of detection algorithms can also be judged. Initial experiences with pacemaker EGMs reveals their potential to detect and diagnose sensing or detection algorithm problems. These so-called "false-positive" EGMs help to optimize pacemaker programming. Date and time stamp can correlate an event to patient symptoms. Recent advances, like onset recordings and marker annotation, have further increased the effectiveness of stored EGMs. The use of patient-triggered magnet-stored EGMs facilitates diagnostic workups in symptomatic pacemaker patients and reveals nondevice related symptoms in a considerable number of cases. Stored EGMs in pacemakers will soon be a standard diagnostic tool that can illustrate what is really going on in our patients.
Because of its cost effectiveness, wide availability, and technical ease of application, ultrasonography is the reference method for determining the thyroid volume prior to radioiodine therapy. The goal of the study is a prospective assessment of the deviation between volumetric ultrasonography measurements in comparison to those performed with three-dimensional magnetic resonance imaging (MRI). To that end, 60 consecutive patients with multinodular toxic goiter (n = 28, 46.7%) or Graves' disease (n = 32, 53.3%) were included in the study. Ultrasonographic volumetry according to the well-known ellipsoid formula was performed by three different technicians. In addition, three-dimensional MRI scans of the neck area were acquired and evaluated by the ellipsoid formula as well as by a dedicated region-of-interest technique (MRI-ROI), which was used as standard of reference. While there was no significant difference between the ultrasonographic examinations of the three technicians, a highly significant mean deviation of 22.7% (10.4 mL) was found between the sonographic measurements and the MRI-ROI results (p < 0.01) that were underestimated in 80% of the cases. Correlation coefficients between the various volumetric approaches were highly significant, with values of at least 0.886 (p < 0.01). An additional analysis of volume-dependent subgroups revealed that thyroid volume had no significant influence on the results of ultrasonographic volumetry (p > 0.15). In conclusion, the study showed ultrasonography to be a reliable method of satisfactory accuracy that is appropriate for volumetric thyroid measurements. The findings indicate that the use of a correction factor higher than 0.52 in the ellipsoid formula is recommended to improve accuracy. However, further studies are necessary to confirm these findings.
BACKGROUND: Pacemaker marker annotations facilitate the interpretation of device behavior in addition to ECG recordings. However, they are only available in conjunction with a programmer. We studied the diagnostic value of a prototype Telemetry Holter Decoder (THD), providing continuous marker annotations on a conventional Holter. METHODS: The study included 20 patients with VDD or DDDR pacemakers. A 24-hour Holter was performed using the THD. Marker annotations are transmitted from the pacemaker to the THD, which transforms them into analog signals, which are recorded on one of the Holter channels. RESULTS: During a total recording time of 458 hours, high quality marker annotations were retrieved for every patient. Artefacts disturbed the recordings during 184 min (0.67%). The THD provided information not discernible on the ECG: intermittent atrial undersensing during sinus rhythm (1096 times). Atrial tachycardias, not visible on the ECG, were detected in 2 patients. The activation of tachycardia response algorithms was clearly annotated in 11,516 events. A total of 8875 PVC's occurred, 57.8% of which were classified incorrectly in the event counters as conducted or fusion beats. Atrial far-field sensing or VA conduction was demonstrated 4294 times. Electromagnetic interferences, not visible on the ECG, could be seen three times. CONCLUSION: Recording of continuous high-quality marker annotation on a conventional Holter is feasible. The THD provides important information on device behavior, even in patients assumed to have regular device function, and shows to be clearly superior to ECG interpretation alone. Such data can be used for improved programming, troubleshooting and for the validation of new algorithms.