Newborn screening for 3-methylcrotonyl-CoA carboxylase deficiency: population heterogeneity of MCCA and MCCB mutations and impact on risk assessment.

New technology enables expansion of newborn screening (NBS) of inborn errors aimed to prevent adverse outcome. In conditions with a large share of asymptomatic phenotypes, the potential harm created by NBS must carefully be weighed against benefit. Policies vary throughout the United States, Australia, and Europe due to limited data on outcome and treatability of candidate screening conditions. We elaborated the rationale for decision making in 3-methylcrotonyl-coenzyme A (CoA) carboxylase deficiency (MCCD), which afflicts leucine catabolism, with reported outcomes ranging from asymptomatic to death. In Bavaria, we screened 677,852 neonates for 25 conditions, including MCCD, based on elevated concentrations of 3-hydroxyisovalerylcarnitine (3-HIVA-C). Genotypes of MCCA (MCCC1) and MCCB (MCCC2) were assessed in identified newborns, their relatives, and in individuals (n = 17) from other regions, and correlated to biochemical and clinical phenotypes. NBS revealed eight newborns and six relatives with MCCD, suggesting a higher frequency than previously assumed (1:84,700). We found a strikingly heterogeneous spectrum of 22 novel and eight reported mutations. Allelic variants were neither related to biochemical nor anamnestic data of our probands showing all asymptomatic or benign phenotypes. Comparative analysis of case reports with NBS data implied that only few individuals (< 10%) develop symptoms. In addition, none of the symptoms reported so far can clearly be attributed to MCCD. MCCD is a genetic condition with low clinical expressivity and penetrance. It largely represents as nondisease. So far, there are no genetic or biochemical markers that would identify the few individuals potentially at risk for harmful clinical expression. The low ratio of benefit to harm was pivotal to the decision to exclude MCCD from NBS in Germany. MCCD may be regarded as exemplary of the ongoing controversy arising from the inclusion of potentially asymptomatic conditions, which generates a psychological burden for afflicted families and a financial burden for health care systems.

Alleles↗

Population spectrum of ACADM genotypes correlated to biochemical phenotypes in newborn screening for medium-chain acyl-CoA dehydrogenase deficiency.

Medium-chain acyl-CoA dehydrogenase deficiency (MCADD) is the most frequent inherited defect of fatty acid oxidation, with a significant morbidity and mortality in undiagnosed patients. Adverse outcomes can effectively be prevented by avoiding metabolic stress and following simple dietary measures. Therefore, prospective newborn screening (NBS) is being proposed for this condition. However, technical validation of MCADD population screening and assessment of its overall benefit require broadening of the as-yet-scarce knowledge of the MCADD genetic heterogeneity unraveled by NBS and its phenotypic consequences. Here, we describe the entire spectrum of sequence variations occurring in newborns with MCADD in the population of Bavaria, Germany, in relation to the biochemical phenotype. Among 524,287 newborns, we identified 62 cases of MCADD, indicating a birth incidence of 1 in 8,456. In all of the 57 newborns available for analysis, two alterations within the MCADD gene (ACADM) were identified. The most prevalent alteration c.985A>G (Lys329Glu) occurred in 27 (47%) newborns in the homozygous and in 18 (32%) in the heterozygous state (63% of defective alleles). The mild folding variant c.199T>C (Tyr67His) was identified in nine individuals, six of them being compound heterozygous with c.985A>G (Lys329Glu). Neither of the prevalent alterations were found in the remaining nine newborns. A total of 18 sequence variations were identified; 13 of them were novel: eight missense mutations, one nonsense mutation, two splice variants, and two small deletions. The remaining five were previously reported in MCADD patients. The ACADM heterogeneity uncovered was larger as anticipated from previous c.985A>G (Lys329Glu) carrier screening data. In addition, we show that MCADD appears to occur as frequently in Turkish newborns as in the native German population. Our data validate that biochemical NBS for MCADD is a highly specific procedure for disease detection, with the identification of a significant share of milder biochemical phenotypes, such as c.199T>C (Tyr67His). These show statistically lower acylcarnitine markers, allowing us to distinguish subgroups within the spectrum of ACADM sequence variations that correlate to biochemical MCADD disease expression. Our data might provide technical and medical guidance for decision making in the worldwide efforts to introduce MCADD population screening.

Acyl-CoA Dehydrogenase↗

Comparison of an internally controlled, large-volume LightCycler assay for detection of Mycobacterium tuberculosis in clinical samples with the COBAS AMPLICOR assay.

We present a sensitive and specific assay for reliable and flexible detection of members of the Mycobacterium tuberculosis complex (MTBC) in clinical samples. This real-time PCR assay, which uses the LightCycler 2.0 instrument and 100-mul glass capillaries, can provide a result within 1 h after DNA extraction. The primers amplify a 206-bp fragment of the MTBC 16S rRNA gene. The sensor hybridization probe targets a region highly specific to members of the MTBC. The assay also includes a novel type of internal control that monitors the function of the reaction components and can detect potential inhibitors. Template DNA was extracted by the same procedure used for the COBAS AMPLICOR M. tuberculosis assay, so the LightCycler assay could be directly compared to the COBAS AMPLICOR assay. The LightCycler assay was evaluated with 146 clinical samples of various types. Very good agreement (100% sensitivity, 98.6% specificity) could be shown between the LightCycler and COBAS AMPLICOR assays. Specificity was checked with a panel of nontuberculous mycobacteria, as well as a large panel of bacterial and fungal organisms.

DNA, Bacterial↗

Rapid second-tier molecular genetic analysis for congenital adrenal hyperplasia attributable to steroid 21-hydroxylase deficiency.

BACKGROUND: Neonatal screening for steroid 21-hydroxylase (CYP21) deficiency is performed to identify congenital adrenal hyperplasia (CAH). The immunologic assay for 17alpha-hydroxyprogesterone (17-OHP) has a high rate of false positives. We assessed the potential for increasing the specificity for CAH by use of a second step involving analysis of the CYP21 gene. METHODS: Between January 1999 and December 2003, a total of 810,000 newborns were screened. Of these, 7920 had to be retested because their 17-OHP values were above the cutoff of the assay. Sixty-one had positive 17-OHP values in their recall samples and were diagnosed as having CAH. We used a rapid assay for common mutations of the CYP21 gene to analyze these 61 samples. In a prospective study, 198 consecutive samples that had increased 17-OHP and 100 samples that had normal 17-OHP concentrations were genotyped. RESULTS: Fifty-nine of 61 cases diagnosed as having CAH were confirmed genetically as CYP21 deficiencies. One patient had a 3beta-hydroxysteroid dehydrogenase deficiency, and one patient carried no CYP21 mutations. The 198 increased 17-OHP results were designated as false positives after immunologic testing of recall samples. None of these samples exhibited the genetic pattern consistent with CYP21 deficiency. CONCLUSIONS: If samples with increased 17-OHP values were screened genetically, the number of retests would decrease by approximately 90%, but the overall sensitivity of CAH screening would remain the same. Adding a second-tier genetic step would require a modest increase in costs, but is counterbalanced by fewer recalls, less clinical follow-up, and a reduction in unnecessary worry for families.

17-alpha-Hydroxyprogesterone↗

Simple technique for internal control of real-time amplification assays.

BACKGROUND: In real-time PCR assays, the most accurate way to identify false-negative results, e.g., those caused by PCR inhibitors, is to add to samples an internal control that will be coamplified with the target (e.g., pathogen) DNA. Current internal control procedures, however, which usually involve the introduction of a DNA fragment, are complex, time-consuming, and expensive. METHODS: Single-stranded oligonucleotides, which contain little more than primer and probe binding sites, were used as internal controls in real-time PCR assays. Mismatches were included in the probe-binding region of the internal control oligonucleotide (ICO) to prevent probe-control hybridization during the fluorescence acquisition step of the PCR. Amplified ICOs were detected by melting point analysis. ICOs could be added directly to the sample material before DNA extraction. RESULTS: To demonstrate the feasibility of the new approach, we designed ICOs for the LightCycler hybridization probe assays for Mycobacterium tuberculosis complex, hepatitis B virus, herpes simplex virus, and varicella zoster virus. In each case, the controls did not interfere with detection of the pathogen, but were clearly detectable during a subsequent melting point analysis. CONCLUSIONS: A single-stranded oligonucleotide that mimics the target region of the pathogen but is clearly distinguishable from the target during melting point analysis can serve as a simple, cost-effective internal control for real-time amplification assays. Such control oligonucleotides are easy to design and inexpensive. A costly second probe system is not necessary. Moreover, the internally controlled assay uses only one fluorescence detection channel of the instrument, leaving the second channel free for multiplex applications.

Base Sequence↗

Advances in analytical mass spectrometry to improve screening for inherited metabolic diseases.

UNLABELLED: Gas chromatography/mass spectrometry became available more than 30 years ago and has subsequently profoundly contributed not only in the identification of a wide range of inborn errors but also as a key tool for clinical diagnostic screening of genetic metabolic disease. Due to extraordinary advances in liquid chromatography and mass spectrometry (MS) developed in the last decade, the utilisation of MS and the potential number of applications for the purpose of metabolic screening is currently undergoing considerable expansion. CONCLUSIONS: This overview aims to describe only current new developments in clinically most relevant applications, in particular with focus on low molecular weight compounds.

Humans↗

Screening for congenital adrenal hyperplasia: adjustment of 17-hydroxyprogesterone cut-off values to both age and birth weight markedly improves the predictive value.

Newborn screening procedures for congenital adrenal hyperplasia (CAH) are still suboptimal because of low specificity, particularly in premature infants. This study evaluated a multitiered strategy for reporting abnormal 17-hydroxyprogesterone screening values that simultaneously takes into account not only birth weight but also age at sampling. A cautious three-tiered cut-off scheme was used during the initial 24 months of CAH screening in Bavaria. Data were then reanalyzed using five birth weight classes to reflect more precisely the markedly higher values in low-birth-weight newborns. Because 17-hydroxyprogesterone values apparently decline with increasing age, these classes were then further subdivided into a total of 21 groups according to the age at sampling. Based on this reanalysis, we defined new multitiered cut-off levels and used them for the next 18 months. A total of 538466 newborns were screened from January 1999 to June 2002; 51 CAH cases were detected. Application of the new threshold values resulted in a 35% reduction of the total recall rate (from 1.13% to 0.74%) and an increase in the positive predictive value from 0.84% to 1.29% without reducing diagnostic sensitivity. This improvement of CAH screening can be achieved by simply using request forms that ask for both age and birth weight at the time of sampling.

17-alpha-Hydroxyprogesterone↗

Type-specific detection of human papillomaviruses in a routine laboratory setting--improved sensitivity and specificity of PCR and sequence analysis compared to direct hybridisation.

Human papillomaviruses (HPV) are known to cause cervical dysplasia and cervical carcinoma. We used a 3-step PCR protocol that allows rapid type-specific HPV testing in a routine laboratory setting: HPV-16-positive samples were determined using a specific LightCycler PCR; HPV-16-negative samples were amplified by nested PCR and typed by sequence analysis. During a period of 7 months, 1275 PCR-based HPV tests were performed. Of the 1275 samples, 829 samples tested negative for HPV and 446 tested positive, including 124 positives found in the initial HPV-16-specific LightCycler assay. Sequence analysis of 132 samples detected 18 HPV types that are not included in the widely used Hybrid Capture II assay. For comparison, the first 100 cervical specimens were tested in parallel using PCR and direct hybridisation (Hybrid Capture II assay). PCR detected HPV DNA in 23 samples that tested negative in the Hybrid Capture assay. Four out of 37 samples that tested positive for HPV in the Hybrid Capture test may be false positives, because sequence analysis detected HPV types not included in the probe mixtures. As rare and novel HPV types may also confer an oncogenic risk, highly sensitive and specific PCR assays will help in understanding cervical HPV infection and cervical cancer of unknown causes.

Adolescent↗

Very high compliance in an expanded MS-MS-based newborn screening program despite written parental consent.

OBJECTIVES: In Bavaria, Germany, an expanded MS-MS-based newborn screening program was implemented in 1999. The coverage of new additional conditions and novelty of technology required introduction of written parental consent. Here we evaluated the influence of the consent procedure on compliance by systematic demographic tracking. METHODS: Comprehensive information was provided for parents, professionals, and the public. Screening notifications were matched with all birth notifications on name and date of birth. Parents of children without screening notification were contacted and counseled. RESULTS: Between August 1, 1999, and July 31, 2000, 123,284 children eligible for screening were born. Of these, 116,652 were matched successfully. Among 6,632 parents contacted, 2,516 (2%) did not respond. Three thousand thirty-four children were screened but the parents initially refused to participate in tracking. Five hundred ninety-four were screened outside the program. Four hundred eighty-eight untested newborns were identified. Three hundred twenty-five screening failures due to logistic problems were tested subsequently. Screening was definitely refused by the parents of 163 children (0.1% of target population). CONCLUSIONS: With appropriate information provided and surveillance by tracking, high compliance with newborn screening can be achieved despite a written consent requirement.

Adult↗

Expanded newborn screening in Bavaria: tracking to achieve requested repeat testing.

OBJECTIVES: Expansion of newborn screening programs may increase the risk of missing cases through procedural failures. A coordinated process quality assurance procedure to track recalls was, therefore, introduced in parallel to expansion (including MS-MS and 17alpha-OHP) in Bavaria. METHODS: Using comprehensive computerized registration and automated monitoring a state-funded center coordinated all individual measures to achieve complete testing of all repeat requests-case-specific contacts to physicians, midwives, and parents. Mailing and phoning from the center were supplemented by local public health activities including home visits if needed. RESULTS: Among 243,422 children tested in 1999 and 2000 overall recall was 3.62% (8,809 children): 0.30% (726) were due to sample inadequacy, 1.35% (3,282) to early sampling (<48 h), and 1.97% (4,801) to abnormal results. Of all recalls, 80.9% were received following the initial request, 1,679 (19.1%) required special efforts. Of these, 873 were achieved following a single and 601 following repeated central activities, and 102 were achieved following local support. Sixty-three cases of parental refusal and 47 untraceable children remained. Altogether, 98.8% recalls were achieved, corresponding to 99.96% of all tested children for which definite screening results could be obtained. CONCLUSIONS: Expansion of newborn screening programs does not necessarily mean unsolvable problems in tracking of recalls if adequate logistics is established in parallel.

Germany↗