PubMed Health⌕ Search

Biomedical subjects

Bernhard Reimers

Publications and source records attributed to Bernhard Reimers.

At least 19 recordsLinked to original sources

Comparison of ticlopidine vs. clopidogrel in addition to aspirin after paclitaxel-eluting stent implantation: insights from the TRUE (Taxusin Real-life Usage Evaluation) Study.

Thienopyridines and aspirin are beneficial in patients undergoing bare-metal stent implantation, and aspirin and clopidogrel treatment have also been proved effective after drug-eluting stent (DES) implantation. However, despite the common substitution of clopidogrel with ticlopidine because of cost or patient intolerance, there are no data on the comparison of ticlopidine vs. clopidogrel after DES implantation. We hereby compare ticlopidine vs. clopidogrel after paclitaxel-eluting stent implantation in subjects enrolled in the prospective multicenter Taxus in Real-life Usage Evaluation (TRUE) Study. Across the 505 analyzed patients (112 treated with ticlopidine and 393 with clopidogrel), similar rates of early and mid-term (7 months) adverse thrombotic events were found with either antiplatelet regimen, with the notable exception of 2 cases of late stent thrombosis in patients who had prematurely withdrawn ticlopidine treatment just 3 months after the procedure. These findings thus support the overall safety and effectiveness of ticlopidine after DES implantation, and also confirm the increased risk of late thrombosis when premature withdrawal of thienopyridines occurs.

Aspirin↗

Direct intramyocardial percutaneous delivery of autologous bone marrow in patients with refractory myocardial angina.

BACKGROUND: Intramyocardial injection of autologous bone marrow (ABM) may induce angiogenesis. We tested the safety and feasibility of catheter-based direct percutaneous intramyocardial delivery of ABM in patients with refractory angina pectoris. METHODS: Ten patients (9 men, 67 +/- 8 years) with refractory angina (Canadian Cardiovascular Society class III-IV) and documented myocardial ischemia were enrolled. After left ventricular electromechanical mapping, freshly aspirated and filtered ABM was percutaneously injected into target myocardial ischemic areas. Clinical symptoms (as assessed according to the Canadian Cardiovascular Society class), quality of life, and myocardial perfusion were evaluated before the procedure and through the follow-up. RESULTS: In all patients, ABM was successfully injected into the target regions. No periprocedural complications occurred. At 12 months, no major cardiac events (death, acute myocardial infarction, stroke, and malignant ventricular arrhythmias) occurred. Severity of angina improved of > or = 2 classes in 3 patients. Quality of life showed a significant improvement in all patients. Myocardial perfusion in the target regions improved in 4 of 8 patients. CONCLUSIONS: Direct percutaneous intramyocardial delivery of ABM appears feasible and safe. Further evaluation is warranted to test its clinical efficacy.

Aged↗

Endovascular treatment of in-stent restenosis after carotid artery stenting: immediate and midterm results.

PURPOSE: To evaluate the immediate and midterm outcome and analyze the debris captured after repeat endovascular intervention for the treatment of in-stent restenosis after carotid artery stenting (CAS). METHODS: Thirty-one consecutive patients (27 men; mean age 63.7+/-13.0 years, range 53- 81) underwent repeat endovascular intervention (balloon angioplasty and provisional stenting) for the treatment of 32 in-stent restenoses following CAS. RESULTS: Procedural success was achieved in all patients. An additional stent was implanted in 10 (31%) cases. No procedural complication was observed. Filter analysis was performed in 17 (53%) procedures; on 12 (71%), macroscopically visible material was captured. The histomorphometric analysis performed on 6 (19%) filters showed fibrin nets entrapping erythrocytes, leucocytes, platelets, and in 2 cases, fibrous hypercellular tissue fragments. At 30 days and during follow-up (mean 17+/-5 months), no deaths, transient ischemic attacks, or strokes were observed. In 1 (3.1%) patient, asymptomatic recurrence of ISR was found on Doppler ultrasonography and successfully treated with balloon angioplasty. CONCLUSION: Repeat endovascular intervention using balloon angioplasty with provisional stenting and routine cerebral protection appears to be a feasible, safe, and clinically effective strategy for the treatment of in-stent restenosis after CAS.

Aged↗

The Frontier stent registry: safety and feasibility of a novel dedicated stent for the treatment of bifurcation coronary artery lesions.

OBJECTIVES: The goal of this study was to evaluate the safety and performance of the Multi-Link Frontier coronary bifurcation stent system (Guidant Corp., Santa Clara, California), a novel dedicated device designed for permanent side branch (SB) access, stent delivery by simultaneous kissing balloon inflation, and optimal main branch (MB) and SB ostium scaffolding. BACKGROUND: The treatment of coronary bifurcation lesions remains challenging, and various approaches using stents have been proposed. METHODS: The primary end point was the 180-day incidence of major adverse cardiac events (MACE) per intent-to-treat analysis. Secondary end points included device success, 30-day MACE, angiographic restenosis, and target lesion revascularization (TLR) rates at 180 days. RESULTS: After a learning phase of two cases per center, 105 patients were prospectively included in 11 centers. The left anterior descending coronary artery/diagonal bifurcation was the target in 80% of cases. The Frontier stent was successfully implanted in 96 patients (91%), and procedural success was obtained in 93%. Two patients suffered in-hospital myocardial infarction (MI) secondary to SB occlusion, and one patient underwent elective coronary artery bypass grafting. At 30 days and 6 months, the MACE rates were 2.9% and 17.1% (no death, no subacute stent thrombosis, Q-wave MI 1.0% and 1.9%, non-Q-wave MI 1.0% and 1.9%, TLR 1.0% and 13.3%). The MB in-stent restenosis was 25.3%, in-segment 29.9%. The SB restenosis was 29.1%. The overall restenosis rate for any branch was 44.8%. CONCLUSIONS: The results of this Frontier registry demonstrate the safety and performance of this dedicated stent system for the treatment of bifurcation lesions. The device can be successfully implanted in more than 90% of all cases, with a high procedural success rate and low 30-day and 6-month MACE rates.

Angioplasty, Balloon, Coronary↗

X-sizer for thrombectomy in acute myocardial infarction improves ST-segment resolution: results of the X-sizer in AMI for negligible embolization and optimal ST resolution (X AMINE ST) trial.

OBJECTIVES: We sought to compare, in a prospective randomized multicenter study, the effect of adjunctive thrombectomy using X-Sizer (eV3, White Bear Lake, Minnesota) before percutaneous coronary intervention (PCI) versus conventional PCI in patients with acute myocardial infarction (AMI) for <12 h and Thrombolysis In Myocardial Infarction (TIMI) flow grade 0 to 1. The primary end point was the magnitude of ST-segment resolution after PCI. BACKGROUND: Despite a high rate of TIMI flow grade 3 achieved by PCI in patients with AMI, myocardial reperfusion remains relatively low. Distal embolization of thrombotic materials may play a major role in this setting. METHODS: We conducted a prospective, randomized, multicenter study in patients with AMI <12 h and initial TIMI flow grade 0 to 1 who were treated with primary PCI. The magnitude of ST-segment resolution 1 h after PCI was the primary end point. RESULTS: A total of 201 patients were included. Treatment groups were comparable by age (61 +/- 13 years), diabetes (22%), previous MI (8%), anterior MI (52%), onset-to-angiogram (258 +/- 173 min), and glycoprotein IIb/IIIa inhibitor use (59%). The magnitude of ST-segment resolution was greater in the X-Sizer group compared with the conventional group (7.5 vs. 4.9 mm, respectively; p = 0.033) as ST-segment resolution >50% (68% vs. 53%; p = 0.037). The occurrence of distal embolization was reduced (2% vs. 10%; p = 0.033) and TIMI flow grade 3 was obtained in 96% vs. 89%, respectively (p = 0.105). Myocardial blush grade 3 was similar (30% vs. 31%; p = NS). Six-month clinical outcome was comparable (death, 6% vs. 4% and major adverse cardiac and cerebral events, 13% vs. 13%, respectively). By multivariate analysis, independent predictors of ST-segment resolution >50% were: younger age, non-anterior MI, use of the X-Sizer, and a short time interval from symptom onset. CONCLUSIONS: Reducing thrombus burden with X-Sizer before stenting leads to better myocardial reperfusion, as illustrated by a reduced risk of distal embolization and better ST-segment resolution.

Angioplasty, Balloon, Coronary↗

Vascular response to sirolimus-eluting stents delivered with a nonaggressive implantation technique: comparison of intravascular ultrasound results from the multicenter, randomized E-SIRIUS, and SIRIUS trials.

BACKGROUND: The effectiveness of SES to reduce the risk of restenosis was initially demonstrated in short lesions using stent implantation with routine pre-dilatation and post-dilatation. This intravascular ultrasound (IVUS) substudy of the E-SIRIUS trial sought to evaluate local arterial responses to sirolimus-eluting stents (SES) delivered with a stent implantation technique allowing direct stenting and only selectively applying high-pressure post-dilatation. METHODS AND RESULTS: IVUS was performed immediately after intervention and at 8-month follow-up in 51 patients randomised to either bare-metal stents (BMS; Bx-Velocitytrade mark; N=20) or SES (Cyphertrade mark N=31). Direct stenting was allowed (24%) and post-dilation was performed only selectively (32%). Lumen dimensions, intimal hyperplasia and vessel remodeling were compared between SES and BMS. Subsequently, results of SES in the E-SIRIUS IVUS substudy (N=31) were compared to those of SES in the IVUS substudy of the SIRIUS trial (N=137). SES in SIRIUS IVUS substudy were delivered with 100% pre-dilatation and 77% post-dilatation. Baseline stent and reference segment measurements were similar between BMS and SES in E-SIRIUS IVUS patients. Using SES there was a 96% reduction in intimal hyperplasia volume within the stented segment (1.8+/-4.9 vs 50.6+/-39.7 mm3, P<0.001) and a significantly larger minimal lumen cross sectional area at 8-month follow-up (4.5+/-1.1 vs 2.3+/-0.9 mm2, P<0.001). No vessel remodeling was observed with the use of SES. The applied stent implantation technique resulted in a minimal stent/reference vessel area ratio of 0.75+/-0.17 in E-SIRIUS SES as compared to 0.84+/-0.23 in SIRIUS SES (P=0.046). Mean intimal hyperplasia cross-sectional area at follow-up was 0.1+/-0.2 mm2 in the SES group of E-SIRIUS and 0.5+/-0.8 mm2 in the SES group of SIRIUS (P=0.003). CONCLUSIONS: An implantation technique of SES which includes direct stenting and minimizes the use of high-pressure post-dilatation results in less optimal stent expansion. However, follow-up results compare very favourable to those of BMS and are characterised by even less intimal hyperplasia than after a more forceful implantation of SES.

Aged↗

Proximal endovascular flow blockage for cerebral protection during carotid artery stenting: results from a prospective multicenter registry.

PURPOSE: To evaluate the feasibility of cerebral protection during carotid artery stenting (CAS) using the Mo.Ma device, which prevents cerebral embolization by proximal endovascular blockage of blood flow in the internal and external carotid arteries. METHODS: In 14 European centers, 157 patients (121 men; mean age 68.0+/-8.3 years) were enrolled in a prospective registry between March 2002 and March 2003. Eligible patients had a symptomatic (>50%) or asymptomatic (>70%) stenosis of the internal carotid artery suitable for carotid stenting. Protected carotid stenting was performed with the Mo.Ma system, which occludes both the common and external carotid arteries via 2 independently inflatable compliant low-pressure balloons before any device is advanced across the lesion. Blood is aspirated through the catheter intermittently or at the end of the procedure. RESULTS: The device was successfully positioned and stents were implanted in all cases. Diameter stenosis was reduced from 84.1%+/-7.8% to 6.7%+/-5.1%. The mean duration of flow blockage was 7.6+/-5.9 minutes. In 12 (7.6%) patients, transient intolerance to flow blockade was observed, but the procedures were completed successfully. In 124 (79.6%) cases, there was macroscopic evidence of debris after filtering the aspirated blood. In-hospital complications included 4 (2.5%) minor strokes, 8 (5.1%) transient ischemic attacks, no deaths, and no major strokes, resulting in a 2.5% death/stroke rate at discharge. At 30-day follow-up, there was 1 cardiac death, 1 major stroke, and 3 minor strokes, for an overall 5.7% 30-day death/stroke rate and a 30-day major stroke and death rate of 1.3%. CONCLUSIONS: Cerebral protection with proximal endovascular blood flow blockage during CAS is feasible, with a high procedural success rate.

Aged↗

High-tech primary percutaneous coronary intervention.

Coronary recanalization by means of primary percutaneous coronary intervention is actually the treatment of choice in patients with ST-elevation myocardial infarction. However, conventional primary percutaneous coronary intervention still presents several limitations. In recent years sophisticated new devices and techniques have been developed to further improve the results of primary percutaneous coronary intervention: it seems to be appropriate to refer to their utilization using the definition "high-tech primary percutaneous coronary intervention". Although the study data available are controversial and clinical benefits have not clearly been shown, adjunctive devices have been used in many procedures. Patient and lesion selection appears to be crucial and the health economics as well as the safety of high-tech devices should be carefully evaluated.

Angioplasty, Balloon, Coronary↗

Cutting balloon versus conventional balloon angioplasty for the treatment of in-stent restenosis: results of the restenosis cutting balloon evaluation trial (RESCUT).

OBJECTIVES: The aim of this trial was to compare cutting balloon angioplasty (CBA) with conventional balloon angioplasty (i.e., percutaneous transluminal coronary angioplasty [PTCA]) for the treatment of patients with coronary in-stent restenosis (ISR). BACKGROUND: Retrospective studies suggest CBA might be superior to conventional PTCA in the treatment of ISR. METHODS: The Restenosis Cutting Balloon Evaluation Trial (RESCUT) is a multicenter, randomized, prospective European trial including 428 patients with all types of ISR (e.g., focal, multifocal, diffuse, proliferative). RESULTS: In both groups, the majority of ISR lesions were shorter than 20 mm. The length of restenotic stents was similar (CBA: 18.6 +/- 9.7 mm; PTCA: 18.3 +/- 8.7 mm). The number of balloons used to treat ISR was lower in the CBA group: only one balloon was used in 82.3% of CBA cases, compared with 75% of PTCA procedures (p = 0.03). Balloon slippage was less frequent in the CBA group (CBA 6.5%, PTCA 25%; p < 0.01). There was a trend toward a lower need for additional stenting in the CBA group (CBA 3.9%, PTCA 8.0%; p = 0.07). At seven-month angiographic follow-up, the binary restenosis rate was not different between the groups (CBA 29.8%, PTCA 31.4%; p = 0.82), with a similar pattern of recurrent restenosis. Clinical events at seven months were also similar. CONCLUSIONS: Cutting balloon angioplasty did not reduce recurrent ISR and major adverse cardiac events, as compared with conventional PTCA. However, CBA was associated with some procedural advantages, such as use of fewer balloons, less requirement for additional stenting, and a lower incidence of balloon slippage.

Angioplasty, Balloon↗

Routine use of cerebral protection during carotid artery stenting: results of a multicenter registry of 753 patients.

PURPOSE: To evaluate the short-term outcome of patients who underwent carotid stenting with the routine use of cerebral protection devices. METHODS: In five centers, 808 successful stent procedures (of 815 attempted) were performed in 753 patients (557 [74%] men; mean [+/- SD] age, 70 +/- 8 years). Cerebral protection involved distal filter devices (n=640), occlusive distal balloons (n=144), or proximal balloon protection (n=24). RESULTS: The protection device was positioned successfully in 793 (98.2%) of the 808 attempted vessels. Neurologic complications occurred within 30 days after 46 procedures (5.6%), including seven major strokes, 17 minor strokes, and 22 transient ischemic attacks. There were four deaths (one following a major stroke). The 30-day incidence of stroke and death was 3.3% (27/815). The rate of stroke or death was 3.8% (8/213) for symptomatic lesions and 3.2% (19/602) for asymptomatic lesions (P=0.87), and 3.4% (25/729) in patients aged <80 years and 2% (2/86) in those aged > or =80 years (P=0.81). Protection device-related vascular complications, none of which led to neurologic symptoms, occurred after nine procedures (1.1%). CONCLUSION: In this uncontrolled study, routine cerebral protection during carotid artery stenting was technically feasible and clinically safe. The incidence of major neurologic complications in this study was lower than in previous reports of carotid artery stenting without cerebral protection.

Aged↗

Early experience with a novel plaque excision system for the treatment of complex coronary lesions.

The use of directional coronary atherectomy (DCA) in current practice has been limited. The SilverHawk System is a newly developed plaque excision device that aims to overcome the drawbacks of prior DCA platforms. The device was evaluated in a porcine coronary model and in a series of patients. Procedural variables along with outcomes were reviewed. Quantitative angiography (QCA) was performed and excised tissue fragments were weighed and examined histologically. In porcine cases, pretreatment MLD increased from 0.51 +/- 0.26 to 2.36 +/- 0.59 mm postdebulking and 19.9 +/- 7.6 mg of tissue was retrieved. In human cases, pretreatment MLD increased from 0.8 +/- 0.4 to 2.2 +/- 0.5 mm postdebulking and 15.2 +/- 7.8 mg of tissue was retrieved without complications. These data show that the SilverHawk System may offer significant utility in treating a wide variety of complex coronary lesions.

Adult↗

Coronary rotational atherectomy in current practice: acute and mid-term results in high- and low-volume centers.

We conducted a prospective observational study to evaluate the indications, technique, in-hospital and 9-month results of consecutive patients treated with rotational atherectomy (RA) in 12 centers during 1 year, as well as their relationship with volume of RA activity. The study included 345 lesions in 289 patients treated (4.4% +/- 2.6% of procedures at the participating centers). The lesions were mostly calcified (63%) and type B2 or C (74%). Procedural success was obtained in 94% of patients, with a major adverse cardiac event (MACE) rate of 4.5%. At 9 months, MACE occurred in 17.3%. Multivariate analysis identified multivessel disease and slow flow as negative predictors of procedural success, whereas balloon pressure <or= 6 atm and hypercholesterolemia were associated with decreased MACE at 9 months. Center RA volume was not associated with in-hospital or 9-month outcome. We conclude that RA, even when used sporadically in selected complex lesions, can provide good immediate and mid-term results.

Adult↗

Intracoronary thrombectomy improves myocardial reperfusion in patients undergoing direct angioplasty for acute myocardial infarction.

OBJECTIVES: We sought to evaluate the effects of mechanical thrombectomy on myocardial reperfusion during direct angioplasty for acute myocardial infarction (AMI). BACKGROUND: Embolization of thrombus and plaque debris may occur during direct angioplasty for AMI. This may lead to distal vessel or side branch occlusion and to obstructions in the microvascular system, resulting in impaired myocardial reperfusion. Mechanical thrombectomy is used to reduce distal embolization. METHODS: Ninety-two patients with AMI and angiographic evidence of intraluminal thrombus were randomized to either intracoronary thrombectomy followed by stenting or to a conventional strategy of stenting. Thrombectomy was performed using the X-Sizer catheter (EndiCOR Inc., San Clemente, California). Myocardial reperfusion was assessed by myocardial blush and ST resolution. RESULTS: Postprocedure Thrombolysis in Myocardial Infarction-3 flow was not different between groups (93.5% vs. 95.7%, p = 0.39). Myocardial blush-3 was observed in 71.7% of patients undergoing thrombectomy and in 36.9% of patients undergoing conventional strategy (p = 0.006). ST-segment resolution >or=50% occurred more often in patients undergoing thrombectomy (82.6% vs. 52.2%, p = 0.001). By multivariate analysis, adjunctive thrombectomy was an independent predictor of blush-3 (odds ratio, 3.27; 95% confidence interval, 1.06 to 10.05; p = 0.039). CONCLUSIONS: Intracoronary thrombectomy as adjunct to stenting during direct angioplasty for AMI improves myocardial reperfusion as assessed by myocardial blush and ST resolution.

Angioplasty, Balloon, Coronary↗

Effectiveness of treatment of in-stent restenosis with an 8-French compatible atherectomy catheter.

The study reports the results of directional atherectomy with an 8Fr guiding catheter-compatible atherectomy catheter in a series of 31 in-stent restenotic lesions. This preliminary experience indicates a favorable safety profile, with events limited to non-Q-wave myocardial infarction occurring in 3.6% of patients. The secondary end point regarding the incidence of angiographic restenosis at 6 months showed a high restenosis rate (65%).

Aged↗

Initial experience with a new 8 French-compatible directional atherectomy catheter: immediate and mid-term results.

The purpose of this study was to evaluate the safety and efficacy of the new Fox Hollow atherectomy device (FHT) designed for more efficient and easier plaque removal. The FHT has short rigid section and low-profile cutter mounted on a monorail catheter. The FHT catheter was utilized in 77 patients with 98 lesions. Mean reference vessel diameter was 2.75 +/- 0.51 mm. Successful atherectomy with tissue retrieval was performed in 94 lesions (96%). Following atherectomy, mean diameter stenosis was reduced from 71.1% to 31.9% and further to 10.4% following adjunctive treatment. Angiographic complications were one coronary perforation and one adventitial staining, both successfully treated with prolong balloon inflation and stent implantation. Nine patients (11.7%) had in-hospital non-Q-wave myocardial infarction (MI). One patient died (1.3%) for noncardiac reasons and one had MI (1.3%) at 6-month follow-up. Target lesion revascularization was required in 13 (13.8%) lesions and target vessel revascularization in 15 (20.3%) patients. There was target vessel failure in 17 (23.0%) patients. Plaque debulking with the FHT catheter can be performed safely and effectively in relatively small vessels and complex lesions located in mid-distal artery segments with 6-month clinical outcome similar to prior atherectomy devices.

Aged↗

A randomized comparison of direct stenting versus stenting with predilatation in native coronary artery disease: results from the multicentric Crosscut study.

Stenting without predilatation has become possible due to the availability of a new generation of flexible, low-profile, securely crimped, balloon-expandable stents. This study compared the feasibility, efficacy and cost-effectiveness of direct stenting (DS) to the standard predilatation technique (PS) using the premounted Crossflex LC stent (Cordis Corporation, Miami Lakes, Florida). The study is a randomized prospective multicenter evaluation including 271 patients (140 patients in the DS group and 131 patients in the PS group) with 1 or 2 de novo or restenotic lesions located in native coronary arteries. Procedural success was 98.9% and 98.7% in the DS and PS groups, respectively (p = NS); crossover to PS was required in 22/166 lesions (13.2%) enrolled in the DS group because of inability to cross the target lesion without predilatation. Nonsignificant reductions in procedural time (-10.5%), fluoroscopy time (-4.7%) and amount of contrast (-3.8%) were observed in the DS group in comparison to the PS group. The number of balloons used (-76.6%) and the global cost of the procedure (-18.8%) were significantly lower in the DS group (p < 0.01 for both comparisons). After 6 months, no differences were observed in the restenosis rate between the two groups (22.0% for DS group versus 18.1% for PS group; p = NS) and in the incidence of major adverse clinical events (5.0% for DS group versus 3.0% for PS group; p = NS). Direct stenting is safe and feasible for the treatment of lesions in native coronary arteries and obtains a significant reduction in procedural cost, mainly due to the lower number of balloons used. Clinical and angiographic results at 6 months are comparable to those obtained after a conventional predilatation-stenting strategy.

Catheterization↗

Distal filter protection during percutaneous coronary intervention in native coronary arteries and saphenous vein grafts in patients with acute coronary syndromes.

BACKGROUND: Percutaneous coronary interventions on saphenous vein grafts (SVG) and in patients with acute coronary syndromes (ACS) have been associated with the distal embolization of the thrombus and plaque and to the no-reflow phenomenon. We report on the safety and feasibility of a new distal emboli protection filter. METHODS: Angioplasty using distal filter protection (Angioguard, Cordis, Warren, NJ, USA) was attempted in 38 patients (mean age 65 +/- 11 years, 79% males) affected by ACS. A percutaneous coronary intervention was performed in 27 native coronary arteries, in 10 SVG and in one arterial graft (mean diameter stenosis 88 +/- 9%). Patients with vessels presenting severe proximal tortuosity, more than mild calcification, a diameter < 3.0 mm and a lesion length > 15 mm were excluded. RESULTS: It was possible to position the device in all patients (100%); in 7 patients (18%) the lesion could be crossed with the filter only after balloon predilation. Procedural success with final TIMI flow 3 was obtained in all patients and the mean residual diameter stenosis after stent implantation was 5 +/- 8%. Transient procedural complications without clinical sequelae included the no-reflow phenomenon (2 patients, 5%) and vessel perforation (1 patient, 2.5%). In no case was distal embolization observed. As regards the device-related complications, one occlusive dissection (2.5%) occurred and was successfully treated with stent implantation. In-hospital and 30-day major adverse cardiac events consisted of two non-Q wave myocardial infarctions (5%), both occurring during SVG interventions. CONCLUSIONS: The use of the Angioguard filter for preselected lesions in patients with ACS had a high technical success and carried a low rate of device-related complications. The clinical efficacy of the device needs further evaluation.

Acute Disease↗

Carotid artery stenting with cerebral protection in 100 consecutive patients: immediate and two-year follow-up results.

BACKGROUND: Carotid artery stenting is emerging as an alternative to surgical endarterectomy for the treatment of extracranial carotid artery disease. However, few data are available on the long-term clinical efficacy of carotid artery stenting and on the incidence of restenosis. METHODS: Stent implantation with the routine use of cerebral protection devices was attempted in a single center experience including 100 consecutive patients (104 lesions) with significant stenosis of the internal carotid artery (mean stenosis 82.8 +/- 9%). The mean age of the patients was 70.8 +/- 14 years, 27 lesions were symptomatic (26.0%) with a lesion related to a previous stroke or transient ischemic attack. RESULTS: Procedural success was achieved in 103 lesions (99%) and the cerebral protection was successfully applied in 102 procedures (98%). The 30-day incidence of stroke and death was 4% (4 patients). Complications consisted of one major stroke (1%) with persistent ipsilateral amaurosis, two minor strokes (2%), and one (1%) fatal myocardial infarction occurring 4 days after the stent procedure. During follow-up (minimum 24 months; mean 31 +/- 6 months) no further neurological events occurred, 6 patients died of non-neurological causes (6%) and 2 (2%) presented with a non-fatal myocardial infarction. Echo color Doppler scan control (minimum 24 months) was carried out in all surviving patients showing a restenosis classified as moderate (50-69%) in 2 cases and as critical (> or = 70%) in another 2 cases (1.8%). Both critical restenotic lesions were successfully treated by repeating balloon angioplasty. CONCLUSIONS: The present study demonstrates that carotid artery stenting with routine cerebral protection can be performed with an acceptable procedural complication rate. At the 2-year follow-up carotid artery stenting appeared effective in stroke prevention and durable with a low incidence of restenosis.

Aged↗