PubMed Health⌕ Search

Biomedical subjects

Bert Hansky

Publications and source records attributed to Bert Hansky.

6 recordsLinked to original sources

Left ventricular pacing through the anterior interventricular vein in a patient with mechanical tricuspid, aortic and mitral valves.

Transvenous endocardial pacemaker implantation is contraindicated in patients after mechanical tricuspid valve replacement. A 76-year-old woman who suffered from bradyarrhythmia was implanted with a left ventricular pacing lead through a transvenous coronary vein after aortic, mitral, and tricuspid valve replacements. There were no complications and the stimulation thresholds were stable. The use of coronary vein leads provides a minimally invasive approach, safety, and effective stimulation for patients with a mechanical tricuspid valve.

Aged↗

Endocardial pacing after Fontan-type procedures.

BACKGROUND: Sinus node dysfunction is a frequent complication of Fontan-type procedure. Epicardial pacing is considered as the standard treatment for these patients. METHODS AND RESULTS: We evaluated an endocardial approach in seven patients using a 4.1 French bipolar lumenless lead (SelectSecure) that is positioned through a steerable guiding catheter. Either a purely transvenous or an open transatrial approach can be used for lead placement. The smallest child weighed 12 kg. Individual anatomy was assessed preimplantation using magnetic resonance imaging and injection of radiographic contrast agent through the guiding catheter. A pullback pressure recording was used to confirm unimpaired blood flow into the pulmonary artery. Five of our seven patients underwent de novo transvenous atrial lead implantation for AAIR pacing. In the remaining two patients, both atrial and ventricular leads were inserted. One patient with an intraatrial tunnel underwent transvenous-lead placement. The remaining patient with an extracardiac conduit received atrial and ventricular leads implanted through a guiding catheter inserted through an atriotomy. The postoperative management included short- or long-term oral anticoagulation. CONCLUSIONS: Transvenous endocardial lead implantation avoids the problem of increasing capture thresholds typically observed with epicardial leads. Due to its high tensile strength and lumenless design, the isodiametric lead is expected to remain extractable for an extended period of time.

Adolescent↗

Effect of cardiac resynchronization therapy on global and regional oxygen consumption and myocardial blood flow in patients with non-ischaemic and ischaemic cardiomyopathy.

AIMS: We studied the effects of cardiac resynchronization therapy (CRT) on global and regional myocardial oxygen consumption (MVO2) and myocardial blood flow (MBF) in non-ischaemic (NICM) and ischaemic dilated cardiomyopathy (ICM). METHODS AND RESULTS: Thirty-one NICM and 11 ICM patients, all of them acute responders, were investigated. MVO2 and MBF were obtained by 11C-acetate PET before and after 4 months of CRT. In NICM global MVO2 and MBF did not change during CRT, while the rate pressure product (RPP) normalized MVO2 increased (P=0.03). Before CRT regional MVO2 and MBF were highest in the lateral wall and lowest in the septum. Under therapy, MVO2 and MBF decreased in the lateral wall (P=0.045) and increased in the septum (P=0.045) resulting in a more uniform distribution. In ICM, global MVO2, MBF, and RPP did not change under CRT. Regional MVO2 and MBF showed no significant changes but a similar tendency in the lateral and septal wall to that in NICM. CONCLUSION: CRT induces changes of MVO2 and MBF on a regional level with a more uniform distribution between the myocardial walls and improved ventricular efficiency in NICM. Based on the investigated parameters, CRT appears to be more effective in NICM than in ICM.

Analysis of Variance↗

Successful heart-lung transplantation in a patient with kyphoscoliosis.

The association is well established between congenital heart disease and spinal deformities such as scoliosis or kyphosis, but data are not available for risks and the outcome of heart surgery in patients with spinal deformities. We report a case of successful orthotopic heart lung transplantation in a patient with complex congenital heart disease and severe chest deformity who had undergone previous spinal fusion surgery for progressive right convex thoracic kyphoscoliosis.

Adolescent↗

Coronary vein balloon angioplasty for left ventricular pacemaker lead implantation.

OBJECTIVES: Retrospective analysis of five cases of coronary vein balloon angioplasty performed to allow insertion of left ventricular pacing leads. BACKGROUND: Coronary vein stenoses or an insufficient vessel caliber can preclude transvenous placement of coronary vein leads. METHODS: We compared our total patient population (n = 218), in whom we implanted coronary vein leads, to those five patients who required coronary vein angioplasty to allow lead placement. Standard over-the-wire coronary artery balloon angioplasty catheters were used to dilate the vessel to 2.5 mm (n = 3) or 3.5 mm (n = 2). RESULTS: Transvenous lead placement succeeds in >99% of patients. Four cases of target vein stenoses and one case of a vein of insufficient caliber were successfully treated by balloon angioplasty. There were no complications. CONCLUSIONS: Coronary vein angioplasty is an effective and safe technique to permit transvenous left ventricular pacing lead insertion in cases of target vein stenoses or insufficient target vein caliber.

Aged↗

Left heart pacing--experience with several types of coronary vein leads.

Our experience with 121 coronary vein (CV) leads in 116 patients shows that CV leads are the leads of choice for pacing the left ventricle (LV). The information gained from pre-operative venous angiography permits individual selection of the most appropriate lead model for each case. The use of steerable electrophysiology catheters facilitates guide catheter cannulation of the coronary sinus (CS) when the anatomy is difficult and reduces the risk of complications. By selecting the CV lead model most suitable for each individual patient, we achieved successful implantation in 99.1% of patients. In this day and age, epicardial electrodes should be restricted to cases with CS anomalies which make CS cannulation impossible, and to LV lead implantation during heart surgery.

Cardiac Pacing, Artificial↗