Importance of right ventricular end-systolic regional wall stress in idiopathic pulmonary arterial hypertension: a new method for estimation of right ventricular wall stress.

RV dysfunction in idiopathic (primary) pulmonary hypertension (IPAH) is often characterized by chamber dilation, ventricular hypertrophy, and impaired systolic function. In this study we characterize right ventricular (RV) chamber size, end-diastolic thickness, myocardial mass, and ejection fraction in patients with right ventricular heart failure from IPAH, n = 16 and compare these characteristics to a control population of cardiac transplant patients (TX, n = 4) and a group of normal subjects (N, n = 5). Subjects underwent both gated cardiac magnetic resonance imaging (MRI) of the right ventricle and right heart catheterization (RHC). Using parameters from both the MRI and RHC, an estimate of RV end-systolic relative wall stress (RWS) was calculated. RV RWS was 34.7 +/- 8.4 and 17.3 +/- 3.8 Kdynes/cm2 in the cardiac transplant and control subjects respectively and was significantly elevated 104.1 Kdynes/cm2 in IPAH patients (IPAH vs N and TX; p = 0.004 and 0.008 ). RV ejection fraction RVEF was lower in IPAH patients 0.36 +/- .10 than in N and TX 0.57 +/- .04 and 0.55 +/- .08 respectively, (p = 0.0006 N and 0.0007 TX). An inverse linear correlation was demonstrated between RWS and RVEF (y = 215- 332x; R = .80, p < or = .0001). Right ventricular RWS is significantly elevated in IPAH and may provide a useful quantitative monitoring tool in patients with IPAH to assess the benefit of different therapeutic interventions and provide prognostic information.

Cardiomegaly↗

Angiographic views used for percutaneous coronary interventions: a three-dimensional analysis of physician-determined vs. computer-generated views.

The goal of this study was to determine the severity of vessel foreshortening in standard angiographic views used during percutaneous coronary intervention (PCI). Coronary angiography is limited by its two-dimensional (2D) representation of three-dimensional (3D) structures. Vessel foreshortening in angiographic images may cause errors in the assessment of lesions or the selection and placement of stents. To date, no technique has existed to quantify these 2D limitations or the performance of physicians in selecting angiographic views. Stent deployment was performed in 156 vessel segments in 149 patients. Using 3D reconstruction models of each patient's coronary tree, vessel foreshortening was measured in the actual working view used for stent deployment. A computer-generated optimal view was then identified for each vessel segment and compared to the working view. Vessel foreshortening ranged from 0 to 50% in the 156 working views used for stent deployment and varied by coronary artery and by vessel segment within each artery. In general, views of the mid circumflex artery were the most foreshortened and views of the right coronary artery were the least foreshortened. Expert-recommended views frequently resulted in more foreshortening than computer-generated optimal views, which had only 0.5% +/- 1.2% foreshortening with < 2% overlap for the same 156 segments. Optimal views differed from the operator-selected working views by > or = 10 degrees in over 90% of vessels and frequently occurred in entirely different imaging quadrants. Vessel foreshortening occurs frequently in standard angiographic projections during stent deployment. If unrecognized by the operator, vessel foreshortening may result in suboptimal clinical results. Modifications to expert-recommended views using 3D reconstruction may improve visualization and the accuracy of stent deployment. These results highlight the limitations of 2D angiography and support the development of real-time 3D techniques to improve visualization during PCI.

Adult↗

Randomized study of the safety and clinical utility of rotational angiography versus standard angiography in the diagnosis of coronary artery disease.

This study evaluates the safety and clinical utility of rotational angiography in the diagnosis of coronary artery disease. High-speed rotational angiography is a newly available angiographic modality that gives a dynamic multiple-angle perspective of the coronary tree during a single contrast injection. We prospectively randomized 56 patients referred for diagnostic coronary angiography to either standard or rotational angiography. Contrast and radiation utilization were compared between the two groups. The number of additional cine acquisitions needed was used to determine adequacy of the diagnostic study protocol. Rotational angiography was successfully completed in all subjects. There was a 33% reduction in contrast utilization in the rotational group as compared to the standard group (35.6 +/- 12.6 vs. 52.8 +/- 10.7 ml, respectively; P < 0.0001). Additionally, there was a 28% reduction in total radiation exposure in the rotational group as compared to the standard group (39.0 +/- 18.5 vs. 53.9 +/- 23.4 Gycm(2), respectively; P = 0.01). Total whole-body radiation exposure to the primary operator was 144 mrem with rotational angiography and 170 mrem with standard angiography. Procedure time tended to be shorter for rotational angiography (353.9 +/- 146.7 vs. 396.8 +/- 165.8 s; P = 0.3). Rotational coronary angiography can be rapidly performed in any patient and provides a significant reduction in contrast and radiation utilization while at the same time providing adequate angiographic data to complement or replace standard coronary angiography in the evaluation of coronary artery disease.

Adult↗

Three-dimensional vascular angiography.

Traditional angiography of the vasculature is limited by its 2-dimensional projection of complex 3-dimensional structures and the consequent imaging artifacts that interfere with visualization. During the last 10 years, technologies capable of minimizing the shortcomings of traditional angiography have been developed and are now in clinical use. Rotational angiography and 3-dimensional imaging are 2 of these powerful tools and, together, represent a major advance in the angiographic diagnosis and treatment of patients with coronary, cerebral, and peripheral vascular disease.

Cardiovascular Diseases↗

Three-dimensional analysis of in vivo coronary stent--coronary artery interactions.

Stent implantation results in important three-dimensional (3D) changes in arterial geometry which may be associated with adverse events. Previous attempts to quantify these 3D changes have been limited by two-dimensional techniques. Using a 3D reconstruction technique, vessel curvatures at end-diastole (ED) and end-systole (ES) were measured before and after stent placement of 100 stents (3 stent cell designs, 6 stent types). After stenting, the mean curvature at ED and ES decreased by 22 and 21%, respectively, and represents a straightening effect on the treated vessel. This effect was proportional to the amount of baseline curvature as high vessel curvature predicted more profound vessel straightening. When analyzed by stent cell design, closed-cell stents resulted in more vessel straightening than other designs (open cell or modified slotted tubes). Stent implantation resulted in the transmission of shape changes to stent ends and generated hinge points or buckling. Stent implantation creates 3D changes in arterial geometry which can be quantified using a 3D reconstruction technique.

Blood Vessel Prosthesis Implantation↗

Angiotensin-converting enzyme DD genotype in patients with primary pulmonary hypertension: increased frequency and association with preserved haemodynamics.

UNLABELLED: HYPOTHESIS/INTRODUCTION: A polymorphic marker within the angiotensin- converting enzyme (ACE) gene has been associated with circulating and tissue ACE activity and with a variety of forms of cardiovascular disease. Since angiotensin II (Ang II) causes pulmonary vasoconstriction and vascular and myocardial remodelling, we postulated a role for the renin-angiotensin system and the ACE DD genotype in the pathophysiology of primary pulmonary hypertension (PPH) and in the right ventricular response to pressure overload in these patients. METHODS AND RESULTS: The incidence of the ACE DD genotype was evaluated in 60 patients with severe PPH compared with two normal control populations, a group of healthy population-based controls (n=158) and subjects found suitable for cardiac organ donation (n=79). Genomic DNA extracted from peripheral leukocytes was amplified using the polymerase chain reaction to detect polymorphic markers. Haemodynamics were determined by right heart catheterisation in a subset of the PPH patients. The frequency of the ACE DD genotype was 45% in the patients with PPH, compared with 24% in the organ donors, and 28% in population-based healthy controls (p=0.01 for chi-square test). Of the 32 PPH patients with baseline haemodynamics, 12 exhibited the ACE DD genotype and 20 were non-DD. While the mean pulmonary artery pressure and the duration of symptoms attributable to pulmonary hypertension was not different between the DD and non-DD groups, cardiac output was significantly lower (3.29+0.27 vs. 5.07+0.37 L/minute, p=0.002) and the mean right atrial pressure tended to be higher (8.85+1.29 vs. 4.92+1.27 mmHg, p=0.08) in the non-DD group. The reduction in cardiac output seen in the non-DD group was not due to a difference in heart rate, but to a significant reduction in stroke volume, consistent with a decreased contractile state. In addition, non-DD patients exhibited a significantly worse functional capacity (NYHA Class 3.14+0.12 vs. 2.40+0.28, p=0.02). CONCLUSIONS: 1) The ACE DD genotype is significantly increased in patients with severe PPH compared with normal controls, suggesting that certain individuals may be genetically predisposed to developing pulmonary hypertension. 2) The ACE DD genotype is associated with preserved right ventricular function in PPH patients, supporting a compensatory myocardial or inotropic role for Ang II in the pressure overloaded right ventricle.

Adult↗

Four-dimensional analysis of cyclic changes in coronary artery shape.

The objective of this study was to derive a method for quantifying the dynamic geometry of coronary arteries. Coronary artery geometry plays an important role in atherosclerosis. Coronary artery geometry also influences the performance of coronary interventions. Conversely, implantation of stents may alter coronary artery geometry. Clinical tools to define vessel shape have not been readily available. Using a Frenet-Serret curvature analysis applied to 3D reconstruction data derived from standard coronary angiograms, 21 coronary arteries were analyzed at end-diastole (ED) and end-systole (ES). Vessels were divided anatomically: type 1 consisted of vessels lying in the AV groove (left circumflex, right coronary) and type 2 consisted of vessels overlying actively contracting myocardium (left anterior descending, diagonal, obtuse marginal, right ventricular marginal, posterior descending, posterolateral). Vessel segments were analyzed by assessing the changes in curvature, torsion, and discrete flexion points (FPs), areas of systolic bending in the arterial contour. The curvature from ED to ES of type 1 vessels was unchanged (-0.02 +/- 0.03 cm(-1)), while the curvature change of type 2 vessels showed a 38% increase (0.33 +/- 0.04 cm(-1); P < 0.001). Type 1 vessels had fewer FPs per vessel than type 2 vessels (0.38 +/- 0.18 and 2.40 +/- 0.23 FP/vessel, respectively; P < 0.001). FPs were more common in distal segments and branch vessels. A method to quantify cyclic changes in coronary artery shape was applied to 3D data sets derived from standard coronary angiograms. Coronary arteries undergo a cyclic change in shape resulting in changes in overall curvature as well as formation of discrete flexion points. These changes in vessel shape are asymmetrically distributed in coronary arteries.

Coronary Angiography↗

Optimal deployment of third-generation stents: an intravascular ultrasound assessment.

Third-generation intracoronary stents allow deployment at higher pressures, possibly obviating the need for high-pressure postdilations and also possibly reducing restenosis. This study evaluated the ability of the Tristar Coronary Stent System to produce optimal stent deployment as measured by intravascular ultrasound (IVUS) and quantitative coronary angiography in 46 patients. Optimal stent deployment was defined as minimal luminal area > 80% of the average of the proximal and distal reference luminal areas. After initial deployment, 74.5% of stents met criteria for optimal stent deployment by IVUS, with an average stent expansion ratio of 89.6%. Ten stents (18.2%) were postdilated. Four patients (8.7%) had a major adverse cardiac event, one patient died, one patient had a myocardial infarction, and two patients had target vessel revascularization at 6 months. The Tristar stent system produces optimal deployment without the need for routine postdilation and results in optimal clinical outcomes.

Adult↗