PubMed Health⌕ Search

Biomedical subjects

Bettina Saar

Publications and source records attributed to Bettina Saar.

4 recordsLinked to original sources

MR cystography for bladder tumor detection.

The purpose of the study was to assess the diagnostic performance of MR cystography with virtual cystoscopic and multiplanar reconstructions for detection of malignant bladder tumors. Thirty-two patients with 43 bladder tumors previously confirmed by cystoscopy (mean size 2.5 cm; 0.4-9.1 cm;) were examined at 1.5 T with a three-dimensional T2-weighted turbo spin echo sequence (TR=2911 ms, TE=500 ms, echo train length 256). Virtual cystoscopic reconstructions (VC) and multiplanar reconstructions (MPR) were obtained and analyzed separately by three radiologists without knowledge of the tumor location. Intraoperative or cystoscopic findings served as standard of reference. Sensitivities and specificities were calculated using a receiver-operating characteristic analysis with five levels of confidence. Area-under-curve values were similar for MPRs (0.952), VC (0.932) and the combination of both methods (0.954). Optimal sensitivity was 92.3% for MPR and 90.7% for VC, respectively, with a specificity of 91.1% for MPR and 90.4% for VC. The combination of MPR and VC resulted in a sensitivity of 90.7% and specificity of 94.0%. MR cystography is a promising, completely non-invasive technique for the detection of bladder lesions with a high diagnostic performance.

Aged↗

Magnetic resonance colonography: a promising new technique.

Colorectal carcinoma is still the second leading cause of cancer-related death, although it arises mostly from benign adenomas. Numerous screening methods are available, but none of them is accepted as ideal. Ultrafast three-dimensional data sets acquired by cross-sectional imaging modalities (CT or magnetic resonance ) in combination with new post-processing modes, known as virtual colonoscopy, have led to a new discussion of screening tests for colorectal cancer. Recently published results indicate a high sensitivity for CT colonography and for MR-based colonography (MRC), with detection rates of greater than 90% for colorectal lesions greater than 10 mm in size. Three-dimensional data acquisition for MRC is performed in less than 1 minute, and no severe complications have been reported. The main advantages of MRC are the lack of ionizing radiation, the low risk of the procedure, and low patient discomfort. MRC has become an attractive diagnostic procedure for colorectal lesions that can also be used as a screening method.

Colonoscopy↗

Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy.

OBJECTIVE: Clinical evaluation of computed tomography (CT) fluoroscopy and comparison with conventional CT guidance for monitoring of percutaneous pulmonary biopsy procedures. METHODS: Twenty CT-guided pulmonary biopsy procedures were conducted. The interventions have prospectively been performed either with CT fluoroscopy or with conventional CT guidance. About 120 kV and 50 mA with a frame-rate of eight images per second were used for CT fluoroscopy. Number of pleural needle passages, procedure times, radiation doses and histologic results were analyzed separately for both methods. RESULTS: Compared with conventional CT guidance, CT fluoroscopy was associated with less pleural needle passages (1.8+/-0.6 vs. 1.1+/-0.3; P=0.003, t-test) and procedure times were shorter than for conventional CT guidance (12.7+/-2.2 min vs. 26.7+/-16.4 min; P=0.02). Analysis of estimated patient related radiation exposure and histologic outcome showed no significant difference between conventional and fluoroscopic CT-guided procedures (P>0.05). CONCLUSION: CT fluoroscopy facilitates guidance of percutaneous pulmonary biopsy procedures. Compared with conventional CT assistance, procedure times are decreased and less pleural needle passages are required. While patient-related radiation exposure is similar, operator-related radiation exposure remains a disadvantage associated with CT fluoroscopy.

Aged↗

Colorectal cancer screening: a challenge for magnetic resonance colonography.

The high incidence of colorectal carcinoma and the fact that colorectal cancer mostly arises from benign adenomas have led to recommendations for screening programs. The introduction of ultrafast three-dimensional datasets acquired by cross-sectional imaging modalities (computed tomography or magnetic resonance imaging) in combination with new postprocessing modes, known as virtual endoscopy, has led to new discussion on the recommendation of screening tests for colorectal cancer. Published results have indicated a high sensitivity for computed tomographic colonography and magnetic resonance-based colonography. Both techniques currently must be combined with colon cleansing. Three-dimensional data acquisition for magnetic resonance-based colonography is less than 1 minute using three-dimensional gradient-echo sequences. The lack of ionizing radiation, the low risk and discomfort to patients, and new techniques of minimized patient preparation make this magnetic resonance technique an attractive diagnostic procedure for colorectal lesions, with many aspects for use as a screening method.

Colonoscopy↗