PubMed Health⌕ Search

Biomedical subjects

Bhavani Jayachandran

Publications and source records attributed to Bhavani Jayachandran.

2 recordsLinked to original sources

Spatial distribution of platelet deposition in stented arterial models under physiologic flow.

This paper presents dynamic flow experiments with fluorescently labeled platelets to allow for spatial observation of wall attachment in inter-strut spacings, to investigate their relationship to flow patterns. Human blood with fluorescently labeled platelets was circulated through an in vitro system that produced physiologic pulsatile flow in a parallel plate flow chamber that contained three different stent designs that feature completely recirculating flow, partially recirculating flow (intermediate strut spacing), and completely reattached flow. Highly resolved spatial distribution of platelets was obtained by imaging fluorescently labeled platelets between the struts. Platelet deposition was higher in areas where flow is directed towards the wall, and lower in areas where flow is directed away from the wall. Flow detachment and reattachment points exhibited very low platelet deposition. Platelet deposition within intermediate strut spacing continued to increase throughout the experimental period, indicating that the deposition rate had not plateaued unlike other strut spacings. The spatial uniformity and temporal increase in platelet deposition for the intermediate strut spacing confirms and helps explain our previous finding that platelet deposition was highest with this strut spacing. Further experimental investigations will include more complex three-dimensional geometries.

Arteries↗

Platelet adhesion to simulated stented surfaces.

PURPOSE: To determine if the protrusion of stent struts into the flow stream, which creates stagnation along the wall dependent on the strut spacing, has an effect on platelet adhesion. METHODS: Three 2-dimensional stents with different strut spacings were placed in a flat-plate flow chamber. Human blood was collected and platelets were labeled with indium 111. The blood with radioactive platelets was pumped through the flow chamber for 30 minutes to produce a pulsatile wall shear stress of 10+/-5 dynes/cm2 (mean +/- amplitude at 1 Hz). A gamma counter measured radioactivity along the surface and on the stents. Computational flow simulations provided specific data on flow separation and wall shear stress for each stent strut spacing tested (2.5, 4.0, and 7.0 times the strut height). RESULTS: The presence of any stent provoked an elevation in platelet adhesion within the stented region (p<0.05). The stents with larger strut spacing had higher platelet adhesion on the substrate in the stented region (1.71+/-0.63 normalized platelet deposition for the 7.0 model and 2.11+/-1.02 for the 4.0 model) than stents with smaller strut spacing (1.37+/-0.68 for the 2.5 model, p<0.05). The stents themselves showed platelet adhesion levels that were 3 to 7 times higher than the substrates, with a similar dependence on stent strut spacing. CONCLUSIONS: Additional knowledge of the role of mechanical factors in stent restenosis will aid in designing stents that minimize intimal hyperplasia and restenosis. The results of this study demonstrate the importance of stent design-mediated blood flow patterns, with smaller strut spacings minimizing platelet adhesion per unit strut area.

Blood Platelets↗