Publications and source records attributed to Bhudatt R Paliwal.

6 recordsLinked to original sources

Imaging dose management using multi-resolution in CT-guided radiation therapy.

In image-guided radiation therapy, megavoltage computerized tomography (MVCT) delivers higher dose to the patient for lower image quality than diagnostic kilovoltage CT (kVCT). One way to reduce the mean imaging dose is to reduce the imaging volume, which is often sufficient for registration and dosimetry purposes. The filtered back projection using truncated data causes artefacts that degrade the image quality. Those artefacts can be effectively reduced by wavelet-based multi-resolution analysis (WMRA), in which the detail and approximate information are reconstructed separately to bypass the non-locality of filtered back projection. In this study, WMRA was used to reconstruct local images from both very low-dose kVCT scans from a bench-top tomotherapy unit and MVCT scans from helical tomotherapy. Results show that mean imaging dose can be significantly reduced by imaging a small region of interest. In simulation, the root-mean-square error brought by the truncation is smaller than 1-2% and depends on the level of dose reduction. On the other hand, the same mean dose that would have been delivered by a low-quality global CT can be conformed to a smaller volume to improve the visibility of low-contrast organs and fine structures using WMRA. Organs at risk can be avoided during repeated daily CT imaging when irregular-shaped reconstruction areas are used. WMRA does not involve computationally expensive iterations and is suitable for image-guided radiation therapy where imaging speed is essential. Compared with extrapolation methods, errors are further reduced to improve the detection of low contrast and fine structures.

Algorithms↗

The American Board of Radiology Maintenance of Certification (MOC) Program in Radiologic Physics.

Maintenance of Certification (MOC) recognizes that in addition to medical knowledge, several essential elements involved in delivering quality care must be developed and maintained throughout one's career. The MOC process is designed to facilitate and document the professional development of each diplomate of The American Board of Radiology (ABR) through its focus on the essential elements of quality care in Diagnostic Radiology and its subspecialties, and in the specialties of Radiation Oncology and Radiologic Physics. The initial elements of the ABR-MOC have been developed in accord with guidelines of The American Board of Medical Specialties. All diplomates with a ten-year, time-limited primary certificate in Diagnostic Radiologic Physics, Therapeutic Radiologic Physics, or Medical Nuclear Physics who wish to maintain certification must successfully complete the requirements of the appropriate ABR-MOC program for their specialty. Holders of multiple certificates must meet ABR-MOC requirements specific to the certificates held. Diplomates with lifelong certificates are not required to participate in the MOC, but are strongly encouraged to do so. MOC is based on documentation of individual participation in the four components of MOC: (1) professional standing, (2) lifelong learning and self-assessment, (3) cognitive expertise, and (4) performance in practice. Within these components, MOC addresses six competencies: medical knowledge, patient care, interpersonal and communication skills, professionalism, practice-based learning and improvement, and systems-based practice.

Certification↗

Technical note: A novel boundary condition using contact elements for finite element based deformable image registration.

Deformable image registration is an important tool for image-guided radiotherapy. Physics-model-based deformable image registration using finite element analysis is one of the methods currently being investigated. The calculation accuracy of finite element analysis is dependent on given boundary conditions, which are usually based on the surface matching of the organ in two images. Such a surface matching, however, is hard to obtain from medical images. In this study, we developed a new boundary condition to circumvent the traditional difficulties. Finite element contact-impact analysis was employed to simulate the interaction between the organ of interest and the surrounding body. The displacement loading is not necessarily specified. The algorithm automatically deforms the organ model into the minimum internal energy state. The analysis was performed on CT images of the lung at two different breathing phases (exhalation and full inhalation). The result gave the displacement vector map inside the lung. Validation of the result showed satisfactory agreement in most parts of the lung. This approach is simple, operator independent and may provide improved accuracy of the prediction of organ deformation.

Algorithms↗

IMRT delivery verification using a spiral phantom.

In this paper we report on the testing and verification of a system for IMRT delivery quality assurance that uses a cylindrical solid water phantom with a spiral trajectory for radiographic film placement. This spiral film technique provides more complete dosimetric verification of the entire IMRT treatment than perpendicular film methods, since it samples a three-dimensional dose subspace rather than using measurements at only one or two depths. As an example, the complete analysis of the predicted and measured spiral films is described for an intracranial IMRT treatment case. The results of this analysis are compared to those of a single field perpendicular film technique that is typically used for IMRT QA. The comparison demonstrates that both methods result in a dosimetric error within a clinical tolerance of 5%, however the spiral phantom QA technique provides a more complete dosimetric verification while being less time consuming. To independently verify the dosimetry obtained with the spiral film, the same IMRT treatment was delivered to a similar phantom in which LiF thermoluminescent dosimeters were arranged along the spiral trajectory. The maximum difference between the predicted and measured TLD data for the 1.8 Gy fraction was 0.06 Gy for a TLD located in a high dose gradient region. This further validates the ability of the spiral phantom QA process to accurately verify delivery of an IMRT plan.

Film Dosimetry↗

Anatomic variation of prescription points and treatment volume with fractionated high-dose rate gynecological brachytherapy.

The purpose of this report is to evaluate the geometric movement (relative to the bony pelvis) and dose variation of brachytherapy reference points in the same patient at repeated high-dose rate (HDR) intracavitary implants. A study was also concluded to find the variation in treatment volume from repeated fractions. Twenty-five consecutive cervical cancer patients (all stages) treated with external beam and fractionated HDR intracavitary implants at the University of Wisconsin were reviewed. Each brachytherapy insertion had a different plan generated prior to treatment delivery. ICRU #38 prescription points (A, B, P, bladder, and rectum) were used. Dose volume histogram was generated and treated volume to the prescription dose was recorded for each fraction. Motion analysis of the various points (from a common origin) in subsequent fractions relative to the first fraction revealed a shift of 2-9 mm in a single plane. Vector analysis revealed the magnitude of the average shift ranged from 10-13 mm. These shifts resulted in a dose difference of >20% for the bladder and rectum points, but < than 8% for the other points. Dose volume histograms revealed that with the change in the anatomy of the cervix and upper vagina during a patient's course of treatment, the treatment volume changes considerably. Thirty-six percent of all patients (9/16) had a reduction in the size of the ovoid during the treatment course. Sixty percent of all patients (15/25) had volume changes <10%. Sixty-two and one half percent of patients (10/16) who did not undergo a reduction of avoid size during the entire course of the treatment had volume change <10%. Since there is a change in the anatomy of the cervix and upper vagina during the course of a treatment along with the irreproducibility of the packing, there is movement of the absolute position of the prescription points between fractions, thus emphasizing the importance of individual dosimetry. Moreover, due to the same reasons, there are significant changes in the treatment volume among implants for the same patient. Volume reduction caused by reduction in ovoid size alone could not be extracted from this study.

Brachytherapy↗