New interface plate for microspray ionization mass spectrometry.

A new interface plate was employed in microspray ionization mass spectrometry (microESI-MS) to improve ion transmission from the sprayer into the sampling nozzle of the mass spectrometer at atmospheric pressure. Using a time-of-flight mass spectrometer (TOFMS), a fivefold increase in ion intensity and a sevenfold reduction in method detection limit were observed. The interface plate attenuated the dependence of the ion intensity on the sprayer position. Even when the distance between the sprayer tip and sampling nozzle was 15.0 mm, ion signals were still stronger than when the sprayer tip was positioned 3.0 mm in front of the sampling nozzle with the original interface plate. This enhancement in the performance of microESI-MS was due to the improved shapes of the equipotential lines near the sprayer tip and the long desolvation distance between the sprayer and the sampling nozzle of the MS.

Journal Article↗

Superimposition of a magnetic field around an ion guide for electron ionization time-of-flight mass spectrometry.

A new electron ionization source was developed for orthogonal acceleration time-of-flight mass spectrometry (TOFMS) based on the superimposition of a magnetic field around a radio frequency-only (rf-only) ion guide. The cylindrically symmetric magnetic field compresses the electron beam from the electron source into a long narrow volume along the ion guide axis. The magnetic field also helps to maintain a narrow energy distribution of electrons that penetrate the full length of the ion guide despite the influence of the radial rf field. Ionization occurs inside the ion guide with improved efficiency resulting from efficient use of electrons, prolonged interaction time, and nontraditionally large ionization volume. At the same time, the rf field effectively focuses ions radially and confines them to the axis of the ion guide by collisional focusing, leading to high ion transmission efficiency. Furthermore, the source can also be operated in a trap-and-pulse mode to improve the ion sampling duty cycle of orthogonal acceleration TOFMS. To validate the design concept of this new ion source, a simple prototype using a single set of cylindrical rods was constructed and retrofitted to an orthogonal acceleration TOFMS. A significant increase in ion signal intensity was observed by operating the source in a pulsed ion extraction mode. Low detection limits (for example, 12 fg for toluene) were determined at 12.5 spectra s(-1) in the full spectrum mode.

Journal Article↗

Electron ionization in superimposed magnetic and radio frequency quadrupolar electric fields.

An improved design of a novel electron ionization source for orthogonal acceleration time-of-flight mass spectrometry is described, based on the superimposition of an axial magnetic field with cylindrical symmetry around a radio frequency-only quadrupole. A tubular permanent magnet was designed to generate the required strong magnetic field and field profile. An axial electric field along the ion guide for efficient ion extraction was introduced using segmented quadrupole rods. Details of the source design and the effects of various operating parameters are described. The source produces high-quality mass spectra with regard to fragmentation, relative abundances, and isotopic ratios. Preliminary results have shown excellent sensitivity, with limits of detection in the subfemtogram range (octafluoronaphthalene, full spectrum acquisition) in gas chromatography/mass spectrometry operation.

Journal Article↗

Assessing analytical specificity in quantitative analysis using tandem mass spectrometry.

OBJECTIVES: The necessity of confirmation of compound identity in quantitative analysis is well recognized for methods utilizing single mass spectrometry detection but is not commonly addressed for applications utilizing multiple-stage mass spectrometry (MSn). For MSn detection, no commonly accepted rules for assessment of analytical specificity in quantitative analyses have been established to date. METHODS: To assure compound identity, we evaluated approaches based on monitoring multiple mass transitions of a target compound followed by comparison of the branching ratios of the mass transitions. RESULTS: Monitoring multiple mass transitions along with evaluation of the ratio of their relative intensities allows the analyst to distinguish the target analyte from interferences in quantitative analysis. The strategy and the acceptance criteria are compound and method specific and should be established during the method development and validation. CONCLUSIONS: The certainty of analyte identity is very important in quantitative analysis using MSn detection; methods to verify analyte identity should be used in all critical applications.

Cortisone↗

Mobility-based selective on-line preconcentration of proteins in capillary electrophoresis by controlling electroosmotic flow.

A simple method to perform selective on-line preconcentration of protein samples in capillary electrophoresis (CE) is described. The selectivity, based on protein electrophoretic mobility, was achieved by controlling electroosmotic flow (EOF). A short section of dialysis hollow fiber, serving as a porous joint, was connected between two lengths of fused silica capillary. High voltage was applied separately to each capillary, and the EOF in the system was controlled independently of the local electric field intensity by controlling the total voltage drop. An equation relating the EOF with the total voltage drop was derived and evaluated experimentally. On-line preconcentration of both positively charged and negatively charged model proteins was demonstrated without using discontinuous background electrolytes, and protein analytes were concentrated by approximately 60-200-fold under various conditions. For positively charged proteins, positive voltages of the same magnitude were applied at the free ends of the connected capillaries while the porous joint was grounded. This provided a zero EOF in the system and a non-zero local electric field in each capillary to drive the positively charged analytes to the porous joint. CE separation was then initiated by switching the polarity of the high voltage over the second capillary. For negatively charged proteins, the procedure was the same except negative voltages were applied at the free ends of the capillaries. Mobility-based selective on-line preconcentration was also demonstrated with two negatively charged proteins, i.e. beta-lactoglobulin B and myoglobin. In this case, negative voltages of different values were applied at the free ends of the capillaries with different values, which provided a non-zero EOF in the system. The direction of EOF was the same as that of the electrophoretic migration velocities of the protein analytes in the first capillary and opposite in the second capillary. By controlling the EOF, beta-lactoglobulin B, which has a higher mobility, could be concentrated over 150-fold with a 15 min injection while myoglobin, which has a lower mobility, was eliminated from the system.

Electrophoresis, Capillary↗

Incorporation of a venturi device in electrospray ionization.

Electrospray ionization has grown to be one of the most commonly used ionization techniques for mass spectrometry, and efforts continue to improve its performance. Typically, the sprayer tip must be very close to the entrance orifice of the mass spectrometer in order to maximize the conduction of ions from the sprayer into the mass spectrometer. However, because of space-charge repulsion, most ions never reach the sampling orifice. In this work, an industrial air amplifier, for which the working mechanism is based on venturi and coanda effects, was added between an electrospray ionization source and a time-of-flight mass spectrometer. When a series of reserpine solutions (0.5, 1.0, 5.0, and 10.0 microM) were monitored using mass spectrometry, an over 5-fold increase in m/z 609.3 ion intensity was measured for a separation distance of 14 mm between the electrospray tip and interface capillary inlet, as compared to when the electrospray tip was in its normal position 1 mm in front of the inlet without the amplifier. When a voltage was applied to the air amplifier to further assist in focusing the electrosprayed ions, an approximately 18-fold increase in m/z 609.3 ion intensity was obtained. In addition, a 34-fold reduction in method detection limit was observed.

Journal Article↗

Application of diaza-18-crown-6-capped beta-cyclodextrin bonded silica particles as chiral stationary phases for ultrahigh pressure capillary liquid chromatography.

Two bonded chiral stationary phases (CSPs), 8-aminoquinoline-2-ylmethyl- and 8-aminoquinoline-7-ylmethyl-diaza-18-crown-6-capped [3-(2-O-beta-cyclodextrin)-2-hydroxypropoxy]propylsilyl silica particles (non-porous, 1.5 microm), have been prepared and evaluated using capillary liquid chromatography at high pressures (> or = 8000 p.s.i.). High column efficiency (up to 400 000 plates m(-1)) was achieved for chiral separations. These CSPs with two recognition sites, i.e. substituted-diaza-18-crown-6 and beta-cyclodextrin combined with high chromatographic efficiency provide good resolution of a variety of enantiomers and positional isomers in relatively short times under reversed-phase conditions. After inclusion of a Ni (II) ion from the mobile phase, the positively charged crown ether-capped beta-cyclodextrin facilitates specific static, dipolar, and host-guest complexation interactions with solutes.

Aza Compounds↗

Elevated-temperature ultrahigh-pressure liquid chromatography using very small polybutadiene-coated nonporous zirconia particles.

Capillary columns packed with small diameter particles typically lead to low permeability and long separation times in high-performance liquid chromatography. Ultrahigh pressures (>10,000 p.s.i.; 1 p.s.i. is identical with 6,894.76 Pa) can be used to overcome the limitations that small particles impose. Ultrahigh-pressure liquid chromatography (UHPLC) has demonstrated great potential for high-speed and high-efficiency separations. Decreasing the viscosity of the mobile phase by elevating the temperature could additionally reduce the pressure drop and facilitate the use of longer columns or smaller particles to achieve even higher total plate numbers. For this reason, we investigated the use of elevated temperatures in UHPLC. Water-resistant, flexible heater tape covered with insulation was used to provide the desired heat to the column. Polybutadiene-coated 1 microm nonporous zirconia particles were used because of their chemical stability at elevated temperature. A column efficiency as high as 420,000 plates m(-1) was obtained. The effects of temperature and pressure on the separation of parabens were investigated. Separation of five herbicides was completed in 60 s using 26,000 p.s.i. and 90 degrees C.

Butadienes↗