Shape-constraint region growing for delineation of hepatic metastases on contrast-enhanced computed tomograph scans.

OBJECTIVES: The objectives of this study were to develop a shape-constraint region-growing algorithm to automatically delineate liver metastases on computed tomography images and to compare automated tumor measurements with those outlined manually by radiologists. METHODS: The algorithm starts with a manual selection of a seed lesion region of interest (ROI). Based on intensity distributions of the seed ROI and the liver parenchyma, several parameters are computed and used to adaptively guide the region growing. To prevent the region growing from leaking into surrounding tissues of similar characteristics, specific shape constraints, including a local shape, a global shape, and a gravity-shift index, are developed to jointly control the iteration of the region growing. The algorithm was applied to 59 lesions in 14 patients with liver metastases. The maximal diameter (unidimension), the product of the maximal and maximal perpendicular diameters (bidimension), and the area in the axial plane were calculated for each of the segmented lesions. Three independent radiologists manually measured all the lesions once, and one of the radiologists measured each lesion 3 times. For each measurement, the concordance correlation coefficient (CCC) was used to assess the pairwise agreement between the computer and the different radiologists, and the overall concordance correlation coefficient (OCCC) was used to assess the agreement between the computer and the multiple radiologists and between the one radiologist's 3 readings. RESULTS: Fifty-three of 59 (89.8%) lesions in 14 patients with liver metastases were successfully segmented using this algorithm. The algorithm achieved a median accuracy of 88.0%. CCCs/OCCCs ranged from 0.943 to 0.999 with 95% confidence intervals. CONCLUSIONS: High accuracy and CCCs/OCCCs suggested that measurements made by the computer were very similar to those made by the radiologists.

Algorithms↗

Marker-controlled watershed for lymphoma segmentation in sequential CT images.

Segmentation of lymphoma containing lymph nodes is a difficult task because of multiple variables associated with the tumor's location, intensity distribution, and contrast to its surrounding tissues. In this paper, we present a reliable and practical marker-controlled watershed algorithm for semi-automated segmentation of lymphoma in sequential CT images. Robust determination of internal and external markers is the key to successful use of the marker-controlled watershed transform in the segmentation of lymphoma and is the focus of this work. The external marker in our algorithm is the circle enclosing the lymphoma in a single slice. The internal marker, however, is determined automatically by combining techniques including Canny edge detection, thresholding, morphological operation, and distance map estimation. To obtain tumor volume, the segmented lymphoma in the current slice needs to be propagated to the adjacent slice to help determine the external and internal markers for delineation of the lymphoma in that slice. The algorithm was applied to 29 lymphomas (size range, 9-53 mm in diameter; mean, 23 mm) in nine patients. A blinded radiologist manually delineated all lymphomas on all slices. The manual result served as the "gold standard" for comparison. Several quantitative methods were applied to objectively evaluate the performance of the segmentation algorithm. The algorithm received a mean overlap, overestimation, and underestimation ratios of 83.2%, 13.5%, and 5.5%, respectively. The mean average boundary distance and Hausdorff boundary distance were 0.7 and 3.7 mm. Preliminary results have shown the potential of this computer algorithm to allow reliable segmentation and quantification of lymphomas on sequential CT images.

Algorithms↗

Lung cancer: computerized quantification of tumor response--initial results.

PURPOSE: To prospectively quantify tumor response or progression in patients with lung cancer by using thin-section computed tomography (CT) and a semiautomated algorithm to calculate tumor volume and other parameter values. MATERIALS AND METHODS: This HIPAA-compliant study was institutional review board approved; informed patient consent was waived. CT scans of 15 measurable non-small cell lung cancers (in five men and 10 women; mean age, 64 years; range, 38-78 years) before and after gefitinib treatment were analyzed. A semiautomated three-dimensional lung cancer segmentation algorithm was developed and applied to each tumor at baseline and follow-up. The computer calculated the greatest diameter (unidimensional measurement), the product of the greatest diameter and the greatest perpendicular diameter (bidimensional measurement), and the volume of each tumor. Exact McNemar tests were used to analyze differences in the percentage change calculated with different measurement techniques. RESULTS: The computer accurately segmented 14 of the 15 tumors. One paramediastinal tumor required manual separation from the mediastinum. Eleven (73%) of the 15 patients had an absolute change in tumor volume of at least 20%, compared with one (7%) and four (27%) patients who had similar changes in unscaled unidimensional (P < .01) and bidimensional (P = .04) tumor measurements, respectively. Seven (47%) patients had an absolute change in tumor volume of at least 30%. In contrast, at unscaled analysis, no patients at unidimensional measurement (P = .02) and two (13%) patients at bidimensional measurement (P = .06) had a change of at least 30%. CONCLUSION: Compared with the unidimensional and bidimensional techniques, semiautomated tumor segmentation enabled the identification of a larger number of patients with absolute changes in tumor volume of at least 20% and 30%.

Adult↗

Pulmonary metastases: effect of CT section thickness on measurement--initial experience.

PURPOSE: To assess the effect of commonly used computed tomographic (CT) section thicknesses on metastatic tumor measurements calculated with unidimensional, bidimensional, area, and volumetric methods. MATERIALS AND METHODS: Analysis and data collection were approved by the Institutional Review Board, with waived informed patient consent. Forty-two pulmonary metastases in 10 patients (three men and seven women; age range, 43-83 years; mean age, 65.4 years) were analyzed on CT scans obtained with 3.75-, 5.0-, and 7.5-mm section thicknesses. The lesions were automatically delineated by using a three-dimensional multicriteria segmentation algorithm. Unidimensional (the largest diameter), bidimensional (the product of the two maximal perpendicular diameters), maximal cross-sectional area, and volumetric measurements were automatically obtained for each pulmonary lesion on each section thickness. Means and variances were calculated, and the differences across the three section thicknesses for each of the four measurements were studied by using linear mixed-effects models. The Levene test was used to study the equality of variances. RESULTS: Differences in the means for unidimensional, bidimensional, and area measurements were significant between a section thickness of 3.75 and 5.0 mm (unidimensional, P=.05; bidimensional, P=.05; area, P=.01) and 3.75 and 7.5 mm (unidimensional, P=.06; bidimensional, P=.03; area, P=.02), but not 5.0 and 7.5 mm. There was a significant difference in volumetric measurement as section thickness decreased from 7.5 to 5.0 mm (P <.001) and from 7.5 to 3.75 mm (P <.001). Although there was a slight trend for differences in the variances across section thickness for each measurement, none of the differences were significant. CONCLUSION: Volumetric tumor measurements change with a reduction in section thickness from 7.5 to 5.0 and 3.75 mm. For unidimensional measurement, no change was found when thickness decreased from 7.5 to 5.0 mm.

Adult↗

Liver segmentation for CT images using GVF snake.

Accurate liver segmentation on computed tomography (CT) images is a challenging task especially at sites where surrounding tissues (e.g., stomach, kidney) have densities similar to that of the liver and lesions reside at the liver edges. We have developed a method for semiautomatic delineation of the liver contours on contrast-enhanced CT images. The method utilizes a snake algorithm with a gradient vector flow (GVF) field as its external force. To improve the performance of the GVF snake in the segmentation of the liver contour, an edge map was obtained with a Canny edge detector, followed by modifications using a liver template and a concavity removal algorithm. With the modified edge map, for which unwanted edges inside the liver were eliminated, the GVF field was computed and an initial liver contour was formed. The snake algorithm was then applied to obtain the actual liver contour. This algorithm was extended to segment the liver volume in a slice-by-slice fashion, where the result of the preceding slice constrained the segmentation of the adjacent slice. 551 two-dimensional liver images from 20 volumetric images with colorectal metastases spreading throughout the livers were delineated using this method, and also manually by a radiologist for evaluation. The difference ratio, which is defined as the percentage ratio of mismatching volume between the computer and the radiologist's results, ranged from 2.9% to 7.6% with a median value of 5.3%.

Algorithms↗

Automatic detection of small lung nodules on CT utilizing a local density maximum algorithm.

Increasingly, computed tomography (CT) offers higher resolution and faster acquisition times. This has resulted in the opportunity to detect small lung nodules, which may represent lung cancers at earlier and potentially more curable stages. However, in the current clinical practice, hundreds of such thin-sectional CT images are generated for each patient and are evaluated by a radiologist in the traditional sense of looking at each image in the axial mode. This results in the potential to miss small nodules and thus potentially miss a cancer. In this paper, we present a computerized method for automated identification of small lung nodules on multislice CT (MSCT) images. The method consists of three steps: (i) separation of the lungs from the other anatomic structures, (ii) detection of nodule candidates in the extracted lungs, and (iii) reduction of false-positives among the detected nodule candidates. A three-dimensional lung mask can be extracted by analyzing density histogram of volumetric chest images followed by a morphological operation. Higher density structures including nodules scattered throughout the lungs can be identified by using a local density maximum algorithm. Information about nodules such as size and compact shape are then incorporated into the algorithm to reduce the detected nodule candidates which are not likely to be nodules. The method was applied to the detection of computer simulated small lung nodules (2 to 7 mm in diameter) and achieved a sensitivity of 84.2% with, on average, five false-positive results per scan. The preliminary results demonstrate the potential of this technique for assisting the detection of small nodules from chest MSCT images.

Algorithms↗

Lymph node segmentation from CT images using fast marching method.

Accurate lymph node size analysis is important medically. This paper presents an improved fast marching method to perform semi-automatic segmentation for lymph node from CT images. In this work, we have incorporated the gray scale information of the target region into the fast marching speed term and have given a hard constraint for the stop criteria, instead of only using the spatial image gradient, to remedy the 'boundary leaking' problem of the traditional fast marching method. Various experimental results are provided to demonstrate the effectiveness of the proposed method.

Humans↗

Characterization of small nodules by automatic segmentation of X-ray computed tomography images.

OBJECTIVE: To characterize the ability of an automatic lung nodule segmentation algorithm to measure small nodule dimensions and growth rates. METHODS: A phantom of 20 sets of 6 balls each (11 different nylon balls and 9 acrylic balls) of 1 to 9.5 mm in diameter, in foam, was imaged using x-ray computed tomography with slice thicknesses of 5, 2.5, and 1.25 mm, pitches of 3 and 6, and standard and lung resolution. Measurements consisted of volume and maximum in-plane cross-sectional areas and their derived maximum and effective diameters. Growth rates were simulated using pairs of groups of balls. RESULTS: Volume measurements overestimate volume, more so for thicker slices. For the largest balls, the error is 60% for 5-mm slices and 20% for 1.25-mm slices. Effective diameter calculated from volume better approximates actual diameter. For area measurements, errors are 0% to 5% for the largest balls, and the effective and actual diameters are closely matched. CONCLUSIONS: Below 5 mm in diameter, changes in volume should reach 100% for reliable indication of growth. Above 6 mm, the threshold for detecting change is on the order of 25% growth. Even under ideal conditions, results indicate the need for caution when making a diagnosis of malignancy on the basis of volume change.

Algorithms↗

Automated quantification of body fat distribution on volumetric computed tomography.

OBJECTIVE: To develop a computerized method to automatically quantify visceral and subcutaneous fat distribution within the abdomen and pelvis on volumetric computed tomographic (CT) images. METHODS: Given the slices of interest, the algorithm automatically delineates a contour that separates the visceral fat from the subcutaneous fat on each slice. Explicitly, starting with extraction of the body perimeter, radii at a fixed angle increment are drawn from the perimeter to the center of the body. Along each radius, intensity profile is analyzed to determine the point on the subcutaneous fat layer that is closest to the body center (inner point). All inner points are then connected to form an inner contour, and a specific smoothing algorithm is subsequently applied to correct suboptimal results. Pixels having HU values between -190 and -30 are considered fat pixels. This procedure is repeated on each of the slices of interest. The visceral and subcutaneous fat volumes computed automatically were compared with those after the radiologist's adjustments. Ratios of volumetric visceral fat-to-total fat and visceral fat-to-subcutaneous fat were compared on average and with single-slice measurements obtained at L4 and L5 vertebral body levels. RESULTS: Subcutaneous and visceral fat were automatically segmented using this algorithm on 419 axial CT slices in 9 CT scans (patients) within the abdomen and pelvis. The overall average percentage difference between the automated segmentation and the segmentation edited by the radiologist were 1.54% for the visceral fat and 0.65% for the subcutaneous fat. CONCLUSIONS: Preliminary results have shown that total compartmental fat, including visceral and subcutaneous fat, can be automatically and accurately segmented on volumetric CT.

Abdominal Fat↗