PubMed Health⌕ Search

Biomedical subjects

Bo Eklof

Publications and source records attributed to Bo Eklof.

At least 19 recordsLinked to original sources

The effect of ultrasound-guided sclerotherapy of incompetent perforator veins on venous clinical severity and disability scores.

PURPOSE: Current techniques to treat venous ulcerations and patients with severe lipodermatosclerosis include the elimination of incompetent perforator veins by open surgical ligation and division or by subfascial endoscopic perforator surgery. An alternative and less invasive means to obliterate perforator veins is ultrasound-guided sclerotherapy (UGS). We hypothesize that UGS is a clinically effective means of eliminating perforator veins and results in improvement of the clinical state (scores) without the complications associated with other more invasive methods. METHODS: Between January 2000 and March 2004, UGS was used to treat chronic venous insufficiency in 80 limbs of 68 patients. This was a clinical series of patients who had perforator incompetence and no previous surgery for venous disease < or = 2 years of their UGS procedure. Most had perforator disease without coexisting axial reflux of the saphenous or deep venous systems. Color flow duplex scanning was used to identify incompetent perforator veins in the calf, and duplex guidance was used to inject each perforator with the liquid sclerosant sodium morrhuate (5%). Patients were restudied by duplex scanning up to 5 years after treatment. Clinical results were determined by Venous Clinical Severity Score (VCSS) and Venous Disability Score (VDS) before and after treatment. RESULTS: Of the 80 limbs treated with UGS, 98% of incompetent perforators were successfully obliterated at the time of treatment, and 75% of limbs showed persistent occlusion of perforators and remained clinically improved with a mean follow-up of 20.1 months. According to the CEAP classification, there were 46.2% with limb ulceration or C6, 1.2% C5, 28.7% C4, 17.5% C3, and 6.2% C2 with pain isolated to the site of the perforator(s). Of those who returned for follow-up, the VCSSs changed from a median of 8 before treatment (95% confidence interval [CI], 3 to 15) to a median of 2 after treatment (95% CI, 0 to 7) (P < .01). Likewise, VDSs dropped from a median of 4 before treatment (95% CI, 1 to 3) to 1 after treatment (95% CI, 0 to 2) (P < .01). There were no cases of deep vein thrombosis involving the deep vein adjacent to the perforator injected. One patient had skin complications with skin necrosis. Perforator recurrence was found more frequently in those with ulcerations than those without. CONCLUSION: UGS is an effective and durable method of eliminating incompetent perforator veins and results in significant reduction of symptoms and signs as determined by venous clinical scores. As an alternative to open interruption or subfascial endoscopic perforator surgery, UGS may lead to fewer skin and wound healing complications. Perforator recurrence occurs particularly in those with ulcerations, and therefore, surveillance duplex scanning after UGS and repeat injections may be needed.

Adult↗

Prevention of air travel-related deep venous thrombosis with mechanical devices: active foot movements produce similar hemodynamic effects.

OBJECTIVE: We compared the hemodynamic effects of different mechanical devices aimed for prevention of travel-related deep venous thrombosis with active foot movements. METHODS: Two battery-operated intermittent pneumatic compression (IPC) devices and three foot and calf muscle pump facilitating devices (PFD) that claimed to prevent travel-related deep venous thrombosis were tested in 17 healthy volunteers on the ground and in 8 of same volunteers during flight. Flow changes during active foot movements were compared with the effects of each of the tested devices. RESULTS: There was no significant difference in hemodynamic effect between PFDs and active foot movements. The hemodynamic effects of IPC devices were significantly less compared with active foot movements. Values obtained during air flights were not significantly different from those obtained on the ground. CONCLUSIONS: Whereas IPC use for prevention of venous stasis during flight can be justified for immobile patients or during sleep, PFDs do not provide additional hemodynamic benefits compared with simple movements of the foot.

Adult↗

Nomenclature of the veins of the lower limb: extensions, refinements, and clinical application.

The relative deficiency of the official Terminologia Anatomica with regard to the veins of the lower limbs was responsible for a nonuniform anatomic nomenclature in the clinical literature. In 2001, an International Interdisciplinary Committee updated and refined the official Terminologia Anatomica regarding the veins of the lower limbs. Recommendations for terminology were included in an updating document that appeared in the Journal of Vascular Surgery (2002;36:416-22). To enhance further the use of a common scientific language, the committee worked on the present document, which includes (1) extensions and refinements regarding the veins of the lower limbs; (2) the nomenclature of the venous system of the pelvis; (3) the use of eponyms; and (4) the use of terms and adjectives of particular importance in clinical vascular anatomy.

Humans↗

Surgical disobliteration of postthrombotic deep veins--endophlebectomy--is feasible.

OBJECTIVE: Partial obstruction of postthrombotic veins is caused by endovenous scar tissue, which creates synechiae and septae that narrow and sometimes block the lumen. We have performed surgical disobliteration, or endophlebectomy, of chronically obstructed venous segments during various kinds of deep venous reconstructions to increase the flow through previously obstructed segments. In this article we describe the endophlebectomy technique, and report the availability of this procedure as an adjunct to deep venous reconstructions for the treatment of postthrombotic chronic venous insufficiency. Patients and methods Between July 1996 and February 2003, surgical disobstruction of 23 deep venous segments was performed in 13 patients in association with 14 deep venous reconstructions to treat advanced postthrombotic chronic venous insufficiency. Postthrombotic veins were surgically exposed, and a longitudinal venotomy was carried out at a variable length. The synechiae and masses attached to the intimal layer were carefully excised. Mean duplex scanning follow-up was 10.8 +/- 8.2 months (median, 8 months; range, 1-28 months). RESULTS: In 10 patients (77%) the treated segments remained primarily patent at median follow-up of 8 months (range, 1-28 months). Early thrombosis near the endophlebectomy site occurred in 3 patients, at 2, 5, and 12 days, respectively, after surgery. In 2 patients with early thrombosis further interventions were carried out with success. In a third patient with early postoperative thrombosis the final outcome was recanalization and reflux. These results yielded an overall secondary patency rate of 93%. No perioperative pulmonary embolism was observed. CONCLUSION: This series demonstrates that surgical disobliteration of postthrombotic deep veins is technically feasible, and led to patency of the segments for the duration of follow-up for up to 28 months (mean, 10.8 +/- 8.2 months). We used this technique with the objective of disobstructing postthrombotic veins, to increase flow through a previously narrowed lumen. Postoperative thrombosis at the site of endophlebectomy occurred in 23% of patients. Although this early experience is encouraging, further studies and longer follow-up are necessary to assess the durability of the procedure.

Feasibility Studies↗

Effect of ethnicity on access and device complications during endovascular aneurysm repair.

INTRODUCTION: There are no published reports on the association between ethnicity and outcome after aortoiliac stent grafting to treat aneurismal disease. Because Hawaii is a state with an ethnically diverse population, we conducted a retrospective study to examine this potential association. We hypothesized that individuals of Asian ancestry may have higher complication rates after endovascular repair compared with non-Asians. METHODS: All endovascular devices placed to treat aneurysm disease from 1996 to 2003 were evaluated in two institutions. The association between ethnicity and access-related and device-related complications, both periprocedural and delayed, was examined with logistic regression analysis. RESULTS: Ninety-two aortoiliac endografts were placed during the study period, including 87 in patients with abdominal aortic aneurysms with or without iliac aneurysm disease, and five patients with isolated iliac artery aneurysms. Forty-four percent of patients were categorized as Asian, 39% as white, 16% as Pacific Islander, and 1% as African American. Access-related and device-related complications (ADRCs) occurred in 11 of 92 (12%) of these patients. The following parameters were significantly associated with ADRCs: Asian ethnicity (P =.015), age greater than 80 years (P =.02), and external iliac diameter smaller than 7.5 mm (P =.01). Asian patients were more likely to have experienced ADRCs than were non-Asian patients (odds ratio, 7.3; 95% confidence interval, 1.5-35.8; P =.015). Asians also had smaller external iliac artery diameters (P =.0003) and more tortuous iliac arteries (P =.03) compared with non-Asians. After adjusting for iliac artery diameter and tortuosity, the association between Asian ethnicity and ARDCs became nonsignificant (P =.074), which suggests that the association between race and complications may be at least in part due to small and tortuous iliac arteries. There was no association between age, gender, or ethnicity and postoperative detection of endoleak. CONCLUSION: Our data indicate that individuals of Asian ancestry are far more likely to experience adverse access-related and device-related complications after aortoiliac stent grafting than are non-Asians. We found that this association is at least partly attributable to the smaller and more tortuous iliac arteries in persons of Asian ancestry.

Aged↗

How often is deep venous reflux eliminated after saphenous vein ablation?

BACKGROUND AND PURPOSE: Deep venous reflux resolution after great saphenous vein surgery has been reported, but the studies evaluated mainly patients with deep segmental reflux. We prospectively analyzed the effects of greater saphenous vein ablation on coexisting primary deep axial venous reflux compared with segmental venous reflux. Patients and methods Between February 1997 and June 2001, patients with primary deep venous reflux scheduled for greater saphenous vein surgery were included in the study. Limbs of patients with a history of deep venous thrombosis, thrombophlebitis, trauma, and orthopedic or venous surgery were excluded. After surgery, duplex scanning was repeated and patients were examined for persistent deep venous reflux. RESULTS: Thirty-three patients (38 limbs) were followed up with duplex scanning. Follow-up ranged from 2 weeks to 38 months. Preoperative axial deep reflux was present in 17 extremities, and segmental reflux was present in 21. The total number of incompetent segments was 59. Overall reflux abolishment rate was similar in extremities with axial and segmental reflux (30% vs 36%; P >.05). When segments were analyzed individually, abolishment of superficial femoral vein reflux was observed more often in extremities with segmental reflux than those with axial reflux (odds ratio, 4). In the extremities where deep reflux was not abolished with greater saphenous vein ablation, degree of reflux did not change significantly (P >.1). Duplex scanning was performed more than once during follow-up in 9 patients. In 3 of these patients reflux resolved by the second follow-up evaluation, and in 2 reflux was decreased at the second and third follow-up evaluations. CONCLUSION: In patients with concomitant deep and superficial venous reflux, saphenous vein ablation results in resolution of deep reflux in about a third of patients. Superficial femoral vein reflux is seldom corrected in limbs with axial reflux compared with those limbs with segmental reflux. To appreciate the effects of greater saphenous vein ablation, longer follow-up may be needed.

Adult↗

Mechanism of venous valve closure and role of the valve in circulation: a new concept.

PURPOSE: The purpose of this study was to investigate the blood flow changes and venous wall movements that occur in the perivalvular area during venous flow, to learn how these physiologic events influence the movements of the valve cusps, and to learn how the movements of the valve cusps influence the venous flow. MATERIALS AND METHODS: Twenty healthy volunteers (10 male, 10 female, age 18 to 52) were subjects of this study. Each volunteer was examined in semi-recumbent and standing positions at rest and during active foot movements. Ultrasound examinations were performed in the B-flow mode supplemented by B-mode and pulsed-wave Doppler scanning. RESULTS: Four phases of the valve cycle are described. During the opening phase (0.27 +/- 0.05 s), the cusps move from the closed position toward the sinus wall. After reaching a certain point, the valves cease opening and enter the equilibrium phase. During this phase (0.65 +/- 0.08 s), the leading edges remain suspended in the flowing stream and undergo self-excited oscillations with an amplitude of 0.01 to 0.16 cm. During the closing phase (0.41 +/- 0.07 sec), the leaflets move synchronously toward the center of the vein. The subsequent closed phase has a duration of 0.45 +/- 0.05 seconds when the cusps remain closed. During the equilibrium phase, flow separation occurs at the leading edge of the cusp with reattachment at the wall of sinus. At this point, flow splits into two streams at each valve cusp. Part of the flow is directed into the sinus pocket behind the valve cusp, forming a vortex along the valve cusp before re-emerging in the main stream in the vein. When the valve is maximally open, the two cusps create a narrowing of the lumen about 35% smaller than the vein distal to the valve. In this narrowed area flow accelerates, forming a proximally directed jet. CONCLUSIONS: The valve cusps undergo the four phases constituting the valve cycle. The local hemodynamic events, such as flow separation and reattachment, and vortical flow in the sinus play important roles in the valve operation. In addition to prevention of retrograde flow, the valve acts as a venous flow modulator. The vortical stream behind the valve cusps participates in the operation of the valve, and prevents stasis inside the valve pocket. The central jet possibly facilitates outflow.

Adolescent↗

Deep axial reflux, an important contributor to skin changes or ulcer in chronic venous disease.

OBJECTIVE: We undertook this cross-sectional study to investigate the distribution of venous reflux and effect of axial reflux in superficial and deep veins and to determine the clinical value of quantifying peak reverse flow velocity and reflux time in limbs with chronic venous disease. PATIENTS AND METHODS: Four hundred one legs (127 with skin changes, 274 without skin changes) in 272 patients were examined with duplex ultrasound scanning, and peak reverse flow velocity and reflux time were measured. Both parameters were graded on a scale of 0 to 4. The sum of reverse flow scores was calculated from seven venous segments, three in superficial veins (great saphenous vein at saphenofemoral junction, great saphenous vein below knee, small saphenous vein) and four in deep veins (common femoral vein, femoral vein, deep femoral vein, popliteal vein). Axial reflux was defined as reflux in the great saphenous vein above and below the knee or in the femoral vein to the popliteal vein below the knee. Reflux parameters and presence or absence of axial reflux in superficial or deep veins were correlated with prevalence of skin changes or ulcer (CEAP class 4-6). RESULTS: The most common anatomic presentation was incompetence in all three systems (superficial, deep, perforator; 46%) or in superficial or perforator veins (28%). Isolated reflux in one system only was rare (15%; superficial, 28 legs; deep, 14 legs; perforator, 18 legs). Deep venous incompetence was present in 244 legs (61%). If common femoral vein reflux was excluded, prevalence of deep venous incompetence was 52%. The cause, according to findings at duplex ultrasound scanning, was primary in 302 legs (75%) and secondary in 99 legs (25%). Presence of axial deep venous reflux increased significantly with prevalence of skin changes or ulcer (C4-C6; odds ratio [OR], 2.7; 95% confidence interval [CI], 1.56-4.67). Of 110 extremities with incompetent popliteal vein, 81 legs had even femoral vein reflux, with significantly more skin changes or ulcer, compared with 29 legs with popliteal reflux alone (P =.025). Legs with skin changes or ulcer had significantly higher total peak reverse flow velocity (P =.006), but the difference for total reflux time did not reach significance (P =.084) compared with legs without skin changes. In contrast, presence of axial reflux in superficial veins did not increase prevalence of skin changes (OR, 0.73; 95% CI, 0.44-1.2). Incompetent perforator veins were observed as often in patients with no skin changes (C0-C3, 215 of 274, 78%) as in patients with skin changes (C4-C6, 106 of 127, 83%; P =.25). CONCLUSION: Continuous axial deep venous reflux is a major contributor to increased prevalence of skin changes or ulcer in patients with chronic venous disease compared with segmental deep venous reflux above or below the knee only. The total peak reverse flow velocity score is significantly higher in patients with skin changes or ulcer. It is questionable whether peak reverse flow velocity and reflux time can be used to quantify venous reflux; however, if they are used, peak reverse flow velocity seems to reflect venous malfunction more appropriately.

Adolescent↗

Hemodynamic effect of intermittent pneumatic compression and the position of the body.

PURPOSE: The purpose of this study was to investigate the three likely mechanisms of intermittent pneumatic compression (IPC) in deep vein thrombosis prophylaxis (increased volume flow, increased flow velocity, and acceleration of flow) and to do this in a variety of positions, in different venous segments, and with the stimulus of three different compression garments. METHODS: In 12 healthy volunteers, three types of compression cuffs were used: foot, calf, and calf + thigh. The foot was compressed with 80 mm Hg, and the calf and thigh with 40 mm Hg. Duplex ultrasound scan was performed before and during the compression in the horizontal, 15-degree head-down, and 15-degree head-up positions. The common femoral, greater saphenous, profunda femoral, superficial femoral, and popliteal veins were examined. RESULTS: In comparison with the horizontal position, the 15-degree head-down position was associated with an increase of volume flow and velocities and the head-up position was associated with decreased flow and velocities in the deep veins. The application of IPC caused significant increases in velocities and volume flow in all venous segments. The lowest increase in velocities and volume flow in the deep veins was observed with the subjects in the head-down position, and in the two other positions, the increases were greater and similar to each other. IPC caused a much more prominent increase in flow velocities and volume flow in deep veins compared with simple elevation of the legs. CONCLUSION: IPC produces significant increases of venous flow volume and flow velocity and acceleration of flow. This is true whether the limbs are elevated, horizontal, or dependent. Segmental flow changes vary with the position of the patient and the compression garment used. Foot compression increases volume flow and velocity primarily in the popliteal vein. Calf compression provides maximal increases of volume flow and flow velocity through the deep veins.

Adult↗

The mechanism of venous valve closure in normal physiologic conditions.

PURPOSE: The purpose of this investigation was to study the mechanism of venous valve closure in physiologic conditions in situ, particularly the clarification of the role of reversed flow through the valve in the closure of the valve cusps. A second purpose was the study of temporal relations between movements of the valve cusps, changes in geometry of venous sinus, and blood flow. METHODS: Twelve healthy volunteers underwent examination with duplex ultrasound scanning. The time relationship between the flow and venous valve movements was analyzed on the basis of real time ultrasound scan records of the saphenofemoral junction. The size and shape of the common femoral vein and the proximal greater saphenous vein were measured with a planimeter. RESULTS: Reverse flow below the valve was registered in only one of the 12 studied subjects. The maximum peak velocity of the reverse flow in this case was 0.8 cm/s and the duration was 0.2 seconds. The reverse flow was registered just before and just after valve closure. The mean duration of the outflow wave below the valve was 816 +/- 57 ms, which was not significantly different from the time of the valve cycle (819 +/- 55 ms; P =.864). The closure of the valve coincided with the decrease of the flow velocities. The first detectable movement of the valve cusps occurred 108 +/- 21 ms after the beginning of the flow deceleration. The mean time interval from the first cusp movement to the complete closure of the valve was 139 +/- 51 ms. Both the size and the shape of the sinus changed during the valve cycle. The size of the sinus increased as much as 127% of the baseline value (1.79 +/- 0.25 cm at baseline; 2.27 +/- 0.23 cm maximum; P =.02), and it became more spheric in shape. The changes in size and shape of the sinus coincided with the movements of the valve cusps. The first detectable change in the sinus size occurred 80 +/- 30 ms after the first detectable movement of the cusps toward closure. CONCLUSION: Reverse flow through the valve is not necessary for the closure of the venous valve. The closure of the venous valve coincides with the decrease of the flow velocities and the ballooning of the sinus (increase of size and the curvature of the valve sinus).

Blood Flow Velocity↗

Reproducibility of ultrasound scan in the assessment of volume flow in the veins of the lower extremities.

PURPOSE: The purpose of this study was the identification of the optimal settings of ultrasound scan flow measurement in the veins and the determination of whether the standardization of these settings can provide acceptable reproducibility of the venous flow measurements in individual segments of the lower extremity veins. METHODS: The venous cross-sectional area, the time average mean velocity, and the venous volume flow of 25 healthy volunteers were examined with duplex ultrasound scanning. Reproducibility was examined with different measurement settings. Doppler scan sample volume size, ultrasound scan beam incident angle, and time interval of measurement were varied across a spectrum for arrival at the setting for highest reproducibility of the flow volume measurements. Test-retest reproducibility of venous flow volume measurements then was investigated with optimized settings. RESULTS: The highest repeatability of volume flow measurements was achieved when the full lumen of the vein was insonated (coefficient of repeatability [CR] = 1.88 cm/s), the ultrasound scan beam incident angle was equal to 60 degrees (CR = 1.56 cm/s), and the measurement time was more than 40 seconds (CR = 1.64 cm/s). The mean values of volume flow were 360 mL/min in the common femoral vein, 147 mL/min in the superficial femoral vein, 86 mL/min in the profunda femoral vein, and 38 mL/min in the greater saphenous vein. Test-retest repeatability coefficients were 96.9 mL/min for the common femoral vein, 70.2 mL/min for the superficial femoral vein, 40.8 mL/min for the profunda femoral vein, and 16.8 mL/min for the greater saphenous vein. CONCLUSION: The reproducibility of ultrasound scan measurements of volume flow in veins is optimized with the use of sampling volumes that cover the entire venous lumen, with an incident angle of 60 degrees and measuring for 40-second intervals or longer. With these defined variables, volumetric measurements are sufficiently repeatable. the values of flow volume measured with duplex ultrasound scanning were comparable to those with thermodilution techniques that were reported previously.

Blood Flow Velocity↗

Changes in venous lumen size and shape do not affect the accuracy of volume flow measurements in healthy volunteers and patients with primary chronic venous insufficiency.

PURPOSE: The purpose of this study was the analysis of the rapid changes in the size and shape of the peripheral vein and the associated changes in blood flow velocities and the estimation of their effect on the reliability of the ultrasound scan volume flow (VF) measurements. METHODS: Ten patients with primary chronic venous insufficiency and 10 healthy volunteers were studied. Two duplex scanners were used simultaneously: one for the velocity measurements in longitudinal plane and another for the cross-sectional area (CSA) measurements in transverse plane during quiet respiration, Valsalva's maneuver (VM), pneumatic cuff compression-decompression, and active dorsiflexion. The patients underwent examination in standing and 15-degrees reverse Trendelenburg's (RT) positions. VF was calculated on the basis of real-time CSA and velocity values. RESULTS: Rapid changes in the CSA as much as 130% for 0.2 seconds were observed. In most cases, the changes in CSA and the flow velocity were inversely related, which resulted in near constant VF. With the exception of VM in the RT position, the difference between real-time VF and mean VF was not significant (P >.05). In the RT position, significant changes in CSA were observed during and immediately after VM. These changes resulted in 23% +/- 15% changes in outflow (both groups) and in 24% +/- 13% changes in reflux (chronic venous insufficiency group). CONCLUSION: The CSA of the peripheral vein and the flow velocities undergo rapid changes during time intervals of a fraction of a second. The vein can have a noncircular cross-section. To minimize the potential error, VF measurements should be performed during quiet respiration or with cuff compression-decompression. With these conditions, the rapid changes in velocities and CSA do not significantly affect the accuracy of VF measurements because of their inverse relation. CSA should be measured planimetrically, or the site of the measurements should be where the vein is close to a circular shape.

Blood Flow Velocity↗

Surgical management of deep venous reflux.

Axial deep venous reflux can be found in the majority of extremities with advanced skin changes and ulceration. It frequently is associated with recurrent disease and tends to progress with time. More than 30 years' experience with deep venous reconstructive surgery, as well as recent advances in diagnostic imaging, makes possible the rational use of such techniques in the management of chronic venous insufficiency. This report reviews the role of deep venous reflux in the natural history and progression of venous disease, the options for surgical correction of deep venous reflux, the current diagnostic abilities and limitations, and the results of surgical interventions.

Humans↗

Air travel-associated venous thromboembolism.

Long-distance air travel is increasing and cases of venous thromboembolism (VTE) following air travel have attracted both considerable public attention and legal claims against airlines. VTE is a common disorder worldwide with a notably high incidence in older individuals. Many biochemical factors that lead to, or accentuate, thrombus formation are associated with increased risk of VTE. These factors include thrombophilia, activated protein C resistance and factor V Leiden, prothrombin gene mutation, antiphospholipid antibodies, protein S and protein C deficiencies, and methylene tetrahydrofolate reductase polymorphism and homocysteinemia. Individual physical characteristics including age, weight and height are significant for personal risk of VTE as are other factors such as use of oral contraceptives in women. In the case of air travel-related venous thrombosis, superimposed upon these individual factors are the environmental factors directly related to air travel. Travel-related factors include stasis associated with prolonged periods of immobility, physiological stresses resulting from exposure to the cabin environment (low humidity and hypoxia) in long-haul flight and other in-flight factors. It is suggested that passenger behavior (movement, avoidance of dehydration and of alcohol) and appropriate pharmacological prophylaxis for high-risk travelers can reduce the likelihood of VTE. Physical prophylaxis (use of compression stockings or in-flight exercise devices) may also be of general benefit to passengers. It is recommended that airlines become more proactive in educating passengers concerning the dangers of VTE and in promoting passenger actions that can reduce risk. Airlines should also work to avoid cramped seating conditions (seat size and pitch) that contribute to prolonged immobility. Governments and regulatory authorities should mandate the provision of adequate seating conditions and a good cabin environment and should support studies that will define risks and determine the efficacy of protocols to minimize dangers of VTE. Increased long-haul air traffic and an aging population suggest that travel-related VTE may present a growing healthcare threat and has highlighted a need for additional biomedical research into the causes and potential solutions to this problem.

Aircraft↗

The influence of obesity on chronic venous disease.

The authors investigate the impact of overweight in patients with chronic venous disease and determine if the eventual effect can be explained by increased venous reflux alone. Patients with chronic venous disease who underwent duplex-ultrasound scanning at the Vascular Center, Straub Clinic and Hospital during 1999 were classified according to the clinical, etiologic, anatomic, and pathophysiologic (CEAP) system and body mass index (kg/m(2)) was calculated. Reflux duration was measured in seconds and peak reverse flow velocity in cm/second. Multi-segment reflux score (total score) was calculated for both reflux duration and peak reverse flow velocity. The reflux pattern and body mass index were correlated to the clinical presentation. Four hundred and one lower extremities (204 right, 197 left) in 272 patients (173 female) with a mean age of 60 years (range 14-90) were investigated. The mean body mass index was 28.9 (+/-7.76). One hundred sixty-seven patients (61%) were overweight (body mass index 25 kg/m(2) or more). There was a significant association between body mass index and the clinical severity (p<0.001). This association persisted after adjustments for total peak reverse flow velocity and total reflux score were made (p<0.001). Overweight patients were more likely to have skin changes and ulceration (p<0.001) than patients with a body mass index less than 25 kg/m(2), despite similar values for total reflux time (p=0.92) and total peak reverse flow velocity (p=0.98). There was an ethnic difference, with Pacific Islanders being significantly heavier and younger compared to patients of white, Asian and Filipino ancestries. The variations in the frequency of skin changes were consistent with ethnic differences in body mass index. The correlation of body mass index with clinical severity independent of reflux measurements indicates that the effect of overweight may involve a mechanism separate from local effects on venous flow. Overweight appears to be a separate risk factor for increased severity of skin changes in patients with chronic venous disease.

Aged↗

Combined percutaneous endovascular and open surgical approach in the treatment of a persistent sciatic artery aneurysm presenting with acute limb-threatening ischemia--a case report and review of the literature.

Persistent sciatic artery (PSA) is a continuation of the internal iliac artery into the popliteal-tibial vessels and provides the major supply to the lower limb bud in early embryologic development, and its remnants participate in the formation of the inferior gluteal, deep femoral, popliteal, peroneal, and pedal vessels. When the femoral artery develops, the PSA involutes. In rare circumstances it persists and has a bilateral location in 22% of cases of PSA. This rare vascular anomaly is associated with aneurysmal formation in 15% to 46% of cases. Persistent sciatic artery aneurysm (PSAA) was first described in 1864. At present 87 cases, including this case, have been reported in the international literature. The authors describe a patient affected with PSAA and treated with a combination of thrombolysis, arterial reconstruction, and aneurysm embolization in a staged fashion. Embryology, anatomy, pathology, clinical presentation, diagnosis, and treatment of this rare disease are briefly discussed.

Aged↗