PubMed Health⌕ Search

Biomedical subjects

Bonnie Punske

Publications and source records attributed to Bonnie Punske.

2 recordsLinked to original sources

Integrin activation in the heart: a link between electrical and contractile dysfunction?

Integrins mechanically link the cytoskeleton to the extracellular matrix in cardiac myocytes and are thereby involved in mechanotransduction. Integrins appear to be necessary for cardiac myocyte hypertrophy. To determine the effect of increased integrin ligation and signaling on adult cardiac function, a heart-specific truncated alpha(5) integrin (gain of function) was conditionally expressed in mice. Four days later, we observed an 80% reduction in amplitude of the QRS complex, profound systolic dysfunction, decreased connexin43, loss of gap junctions, and abnormal intercalated discs. Surprisingly, isolated left ventricular myocytes contracted normally and exhibited normal Ca(2+) transients. This suggested that cell/cell electrical and/or mechanical coupling was disrupted. To distinguish electrical from mechanical coupling deficits, we compared the papillary muscle force generated by electrically stimulated versus rapid cooling contractions in which intracellular Ca(2+) is released without electrical depolarization. Both were decreased in the transgenic muscle. However, electrically stimulated contractions were more significantly reduced than rapid cooling contractures. This suggests a component of cell/cell electrical uncoupling. Optical mapping revealed a loss of the normal elliptical isochronal activation pattern implying a loss of preferential conduction through gap junctions. For the first time, we have shown that integrins can regulate both mechanical and electrical coupling in the adult heart, even in the absence of primary hemodynamic alterations. Furthermore, we demonstrated that unregulated integrin activation leads to both contractile dysfunction and arrhythmias.

Animals↗

Endocardial mapping of electrophysiologically abnormal substrates and cardiac arrhythmias using a noncontact nonexpandable catheter.

INTRODUCTION: In previous studies, we established methodology for reconstructing endocardial potential maps, electrograms, and isochrones from a noncontact intracavitary catheter during a single beat. Recently, we evaluated this approach using a 9-French (3-mm) spiral catheter in a normal heart preparation. Here we extend the approach to hearts with structural disease and examine its ability to detect and characterize abnormal electrophysiologic (EP) substrates and to map ventricular arrhythmias on a beat-by-beat basis. METHODS AND RESULTS: Reconstruction of endocardial potentials from cavity potentials measured with 82 electrodes mounted on a 9-French spiral catheter was performed in an isolated canine left ventricle (LV). Endocardial potentials were recorded with 91 intramural needles, providing a gold standard for evaluating the noncontact reconstruction. Studies were performed in a normal LV (control) and the same LV 3 hours after left anterior descending coronary artery occlusion and ethanol injection to create an infarct. Abnormal EP characteristics over the infarct were faithfully reconstructed, including (1) low potentials and electrogram derivatives; (2) fractionated electrograms; (3) small deflections on electrograms reflecting local activation; and (4) slow discontinuous conduction transverse to fibers. During arrhythmia, beat-to-beat dynamic shifts of initiation site and activation pattern were captured by the reconstruction. CONCLUSION: Noncontact, nonexpendable catheter mapping can locate and characterize abnormal EP substrates and can capture the endocardial sequence of an arrhythmia during a single beat.

Animals↗