PubMed Health⌕ Search

Biomedical subjects

Bora Ozturk

Publications and source records attributed to Bora Ozturk.

7 recordsLinked to original sources

Microtensile bond strength of two resin composite materials placed with direct and indirect techniques under simulated pulpal pressure.

PURPOSE: The aim of this in vitro study was to compare the dentin bond strength of directly and indirectly inserted composite restorations. MATERIALS AND METHODS: Twenty extracted human mandibular molars were prepared to form a flat occlusal dentin surface using an Isomet saw under water. Five-mm-thick composite restorations (Filtek Z 250 and Clearfil AP-X) were placed on the dentin surfaces by direct or indirect techniques. The direct restorations were bonded with Single Bond and Clearfil SE Bond bonding agents. Indirect restorations were cemented with two composite luting cements (3M Opal Luting Cement and Panavia F). All restorative procedures were applied under simulated pulpal pressure (15 cm H2O). Each tooth was then vertically sectioned with an Isomet saw through the composite buildups and the dentin. Thus, for microtensile testing, 0.65 x 0.65 mm specimens were obtained from pulpal and remote dentin regions. The results were analyzed according to the regional dentinal surfaces (pulpal and remote dentin). For statistical analyses, two-way ANOVA and Duncan post-hoc tests were used (p < 0.05). RESULTS: Direct application of Clearfil AP-X showed that tensile bond strengths were higher than those obtained for directly and indirectly applied Filtek Z 250 and indirectly applied Clearfil AP-X. No significant difference in tensile bond strengths was demonstrated between pulpal and remote dentin (p > 0.05). CONCLUSION: It is concluded that the bond strengths of resin luting cements to dentin need further improvement.

Analysis of Variance↗

Effect of tooth age on microtensile bond strength of two fluoride-releasing bonding agents.

PURPOSE: The purpose of this study was to evaluate the effect of age of dentin and enamel on the microtensile bond strengths of a glass-ionomer based, all-in-one, single-step, self-etching adhesive system (Reactmer Bond, RB) and an antibacterial, two-step self-etching primer system (ABF Bond, ABF). MATERIALS AND METHODS: Extracted molars from 3 age groups (20 to 25, 35 to 40, and 50 to 55 years) were used. Enamel was removed from the occlusal surfaces of the teeth, and the entire flat surfaces were covered with composite resin (4 mm in height) following application of bonding agents. The bonded specimens were thinly sectioned parallel to the long axis of the tooth into 0.87 +/- 0.03 mm2 rectangular sections, resulting in 6 to 7 enamel specimens and 10 to 15 dentin specimens per tooth. The specimens were subjected to the microtensile test at a crosshead speed of 1 mm/min. The data were analyzed by Univariate ANOVA, Tukey HSD, and regression analysis. RESULTS: The bond strength of ABF to both enamel and dentin was higher than the bond strength of RB. Bond strengths of ABF to dentin were significantly higher than the bond strengths to enamel (p < 0.05). The 35- to 40-year age group of ABF showed the highest bond strength of all. In RB dentin groups, 34% of specimens showed cohesive failure in composite resin material. CONCLUSION: Bond strength values to enamel were not affected by age of teeth in either bonding system. Dentinal bond strength using ABF changed according to age of the teeth. Age did not affect bond strength values of RB to dental hard tissues. However, the high number of cohesive failures in Reactmer paste indicated low tensile strength of the material.

Adhesiveness↗

An interdisciplinary approach for restoring function and esthetics in a patient with amelogenesis imperfecta and malocclusion: a clinical report.

This clinical report describes an interdisciplinary approach for the coordinated treatment of a patient diagnosed with amelogenesis imperfecta and malocclusion. The patient's functional and esthetic expectations were successfully met with interdisciplinary treatments, including orthodontics, porcelain laminate veneers, metal-ceramic fixed partial dentures, and direct composite restorations.

Adult↗

Effect of NaOCl on bond strengths of bonding agents to pulp chamber lateral walls.

The objective of this study was to evaluate the effects of 5% NaOCl on bond strengths of four bonding systems-Clearfil SE Bond, Prompt L-Pop, Prime&Bond NT, and Scotchbond Multi Purpose Plus-to pulp chamber mesial walls. Forty mandibular third molar teeth were used in the study. The pulp chambers of the first 20 teeth were restored with bonding agents and composite resins after 5% NaOCl irrigation, and the remaining teeth were restored without 5% NaOCl treatment. Each bonding group had five teeth. Three rectangular thin sticks (1+/-0.03 mm) were obtained from the mesial wall of restored pulp chambers by horizontal sectioning. In general, NaOCl application decreased the bond strength values of the bonding agents. Both Clearfil SE Bond and Prompt L-Pop without NaOCL showed higher bond strength values than the other bonding groups. In NaOCl-applied groups, Clearfil SE Bond had the highest bond strength. It can be concluded that self-etching bonding systems are more successful than the other systems in bonding to pulp chamber dentinal wall and that NaOCl reduces bond strength.

Acid Etching, Dental↗

Temperature rise during adhesive and resin composite polymerization with various light curing sources.

This study evaluated the temperature rise in two different adhesive (Clearfil SE Bond [CSEB] and EBS-Multi [EBSM]) and composite systems (Clearfil AP-X [CAPX,] Pertac II [PII]) by the same manufacturer when illuminated by four different light sources: Light-emitting diode (LED), Plasma arc curing (PAC), high intensity quartz tungsten halogen (HQTH) and quartz tungsten halogen (QTH). Forty dentin disks were prepared from extracted premolars. These dentin disks were placed in apparatus developed to measure temperature rise. Temperature rise during photopolymerization of adhesive resin and resin composite was then measured. The mean values of temperature increases for adhesive and resin composites did not differ significantly (p=0.769). The highest temperature rise was observed during photopolymerization of EBSM with PAC (5.16 degrees C) and HQTH (4.28 degrees C), respectively. Temperature rise values produced by QTH (1.27 degrees C - 2.83 degrees C for adhesive resin; 1.86 degrees C - 2.85 degrees C for resin composite) for both adhesive and resin composites were significantly lower than those induced by PAC and HQTH (p<0.05). However, these values were significantly higher than those produced by LED (1.16 degrees C - 2.08 degrees C for adhesive resin; 1.13 degrees C - 2.59 degrees C for resin composite). Light sources with high energy output (PAC and HQTH) caused significantly higher temperature rise than sources with low energy output (QTH and LED). However, in this study, no temperature rises beneath 1-mm dentin disk exceed the critical 5.6 degrees C value for pulpal health.

Analysis of Variance↗

Degree of conversion and surface hardness of resin cement cured with different curing units.

OBJECTIVE: The aim of this study was to evaluate the degree of conversion and Vickers surface hardness of resin cement under a simulated ceramic restoration with 3 different curing units: a conventional halogen unit, a high-intensity halogen unit, and a light-emitting diode system. METHODS AND MATERIALS: A conventional halogen curing unit (Hilux 550) (40 s), a high-intensity halogen curing unit used in conventional and ramp mode (Optilux 501) (10 s and 20 s, respectively), and a light-emitting diode system (Elipar FreeLight) (20 s, 40 s) were used in this study. The dual-curing resin cement (Variolink II) was cured under a simulated ceramic restoration (diameter 5 mm, height 2 mm), and the degree of conversion and Vickers surface hardness were measured. For degree of conversion measurement, 10 specimens were prepared for each group. The absorbance peaks were recorded using the diffuse-reflection mode of Fourier transformation infrared spectroscopy. For Vickers surface hardness measurement, 10 specimens were prepared for each group. A load of 200 N was applied for 15 seconds, and 3 evaluations of each of the samples were performed. RESULTS: Degree of conversion achieved with Optilux 501 (20 s) was significantly higher than those of Hilux, Optilux 501 (10 s), Elipar FreeLight (20 s), and Elipar FreeLight (40 s). For Vickers surface hardness measurement, Optilux 501 (20 s) produced the highest surface hardness value. No significant differences were found among the Hilux, Optilux 501 (10 s), Elipar FreeLight (20 s), and Elipar FreeLight (40 s). CONCLUSION: The high-intensity halogen curing unit used in ramp mode (20 s) produced harder resin cement surfaces than did the conventional halogen curing unit, high-intensity halogen curing unit used in conventional mode (10 s) and light-emitting diode system (20 s, 40 s), when cured through a simulated ceramic restoration.

Dental Porcelain↗

Two-year color changes of light-cured composites: influence of different light-curing units.

This study determined color changes in a composite cured with various types of curing units after two years. A hybrid (Clearfil AP-X) composite was cured with a conventional halogen, a high intensity halogen, a plasma arc and a light emitting diode unit. The specimens were stored in light-proof boxes after the curing procedure to avoid further exposure to light and stored in 37 degrees C in 100% humidity. Colorimetric values of the specimens immediately after curing and after two years were measured using a colorimeter. The CIE 1976 L*a*b color system was used to determine color differences. Differences from baseline were calculated as deltaE*ab. Data were analyzed with two-way analysis of variance (p<0.05). The deltaE*ab values varied significantly, depending on the curing unit used. The specimens cured with a plasma arc curing unit induced significantly higher color changes than any other specimen and the color differences were also visually appreciable by the non-skilled operator (deltaE*ab >2.5). The specimens cured with a high intensity halogen curing unit produced the lowest color change; however, there were no statistically significant differences among the color changes of specimens cured with conventional halogen, high intensity halogen and the light emitting diode unit, and the color changes were not clinically relevant (deltaE*ab <2.5). The results of this study suggest that composite materials undergo measurable changes due to curing unit exposure. The specimens cured with a plasma arc light showed the highest color changes as compared to specimens cured with other curing units.

Analysis of Variance↗