PubMed Health⌕ Search

Biomedical subjects

Boriana Parvez

Publications and source records attributed to Boriana Parvez.

8 recordsLinked to original sources

A randomized, controlled trial of heparin versus placebo infusion to prolong the usability of peripherally placed percutaneous central venous catheters (PCVCs) in neonates: the HIP (Heparin Infusion for PCVC) study.

BACKGROUND: Mechanical and infectious complications shorten the effective duration of peripherally inserted central venous catheters. Heparin use to prevent such complications and prolong the usability of peripherally inserted central venous catheters is inconclusive. OBJECTIVE: Our goal was to evaluate the effectiveness of heparin in prolonging the usability of peripherally inserted central venous catheters in neonates. DESIGN/METHODS: We performed a multicenter, randomized, controlled trial of heparin infusion (0.5 U/kg per hour) versus placebo for peripherally inserted central venous catheters in neonates. The primary outcome was duration of catheter use. Secondary outcomes were occlusion, catheter-related sepsis, thrombosis, and adverse effects of heparin. To detect a 168-hour (1-week) difference in the duration of catheter use, 192 patients were needed. Kaplan-Meier and Cox regression analyses were performed. RESULTS: A total of 201 neonates were enrolled (heparin group: n = 100; control group: n = 101). Baseline demographics were similar between the groups. Duration of catheter use was longer in the infants in the heparin versus the placebo group. Study center, gender, birth weight, and type and position of the catheter were not predictors of duration of catheter use. For those in the heparin versus the placebo group, the incidence of elective catheter removal (therapy completed) was 63% vs 42%, of occlusion was 6% vs 31%, of thrombosis was 20% vs 21%, and of catheter-related sepsis was 10% vs 6%, respectively. No adverse events were noted. CONCLUSIONS: Heparin infusion prolonged the duration of peripherally inserted central venous catheter usability, which permitted a higher percentage of neonates to complete therapy without increasing adverse effects.

Anticoagulants↗

Intravenous morphine and topical tetracaine for treatment of pain in [corrected] neonates undergoing central line placement.

CONTEXT: There is limited evidence of the analgesic effectiveness of opioid analgesia or topical anesthesia during central line placement in neonates, and there are no previous studies of their relative effectiveness. OBJECTIVE: To determine the effectiveness and safety of topical tetracaine, intravenous morphine, or tetracaine plus morphine for alleviating pain in ventilated neonates during central line placement. DESIGN, SETTING, AND PARTICIPANTS: Randomized, double-blind, controlled trial enrolling 132 ventilated neonates (mean gestational age, 30.6 [SD, 4.6] weeks at study entry) and conducted between October 2000 and July 2005 in 2 neonatal intensive care units in Toronto, Ontario. INTERVENTIONS: Prior to central line insertion, neonates were randomly assigned to receive tetracaine (n = 42), morphine (n = 38), or both (n = 31); a separate nonrandomized group of 21 neonates receiving neither tetracaine nor morphine was used as a control group. MAIN OUTCOME MEASURES: The primary outcome measure was a pain score for the proportion of time neonates displayed facial grimacing (brow bulge) during different phases of the procedure (skin preparation, needle puncture, and recovery). In randomized neonates, safety assessments included blood pressure, ventilatory support, and local skin reactions. RESULTS: Compared with no treatment, pain scores were lower in the morphine and tetracaine-morphine groups during skin preparation (mean difference, -0.22; 95% confidence interval [CI], -0.4 to -0.04; P = .02 and -0.29; 95% CI, -0.49 to -0.09; P = .01, respectively), and needle puncture (mean difference, -0.35; 95% CI, -0.57 to -0.13; P = .003 and -0.47; 95% CI, -0.71 to -0.24; P<.001, respectively), but pain scores did not differ statistically for tetracaine alone vs no treatment. Pain scores were lower for morphine and tetracaine-morphine vs tetracaine during the skin preparation phase and for tetracaine-morphine vs tetracaine during needle puncture. Compared with neonates without morphine, morphine-treated neonates required larger increases in ventilation rate in the first 12 hours (mean difference, 3.9/min; 95% CI, 1.3-6.5/min; P = .003). Local skin reactions occurred in 30% of neonates given tetracaine vs 0% for morphine (risk difference, 0.30; 95% CI, 0.19-0.41; P<.001). CONCLUSION: In this study of ventilated neonates undergoing central line placement, morphine and tetracaine plus morphine provided superior analgesia to tetracaine; however, morphine caused respiratory depression and tetracaine caused erythema.Clinical Trials Registration ClinicalTrials.gov Identifier: NCT00213200.

Administration, Topical↗

Portal vein thrombosis in the neonate: risk factors, course, and outcome.

OBJECTIVE: To determine the risk factors, clinical features, and outcome of infants diagnosed with portal vein thrombosis (PVT). STUDY DESIGN: A retrospective chart review was conducted of all consecutive infants admitted to the Hospital for Sick Children, Toronto, between January 1999 and December 2003 diagnosed with PVT. RESULTS: PVT was diagnosed in 133 infants, all but 5 of whom were neonates, with a median age at time of diagnosis of 7 days. An umbilical venous catheter (UVC) was inserted in 73% of the infants and was in an appropriate position in 46% of them. Poor outcome, defined as portal hypertension or lobar atrophy, was diagnosed in 27% of the infants and was significantly more common in those with an initial diagnosis of grade 3 PVT and in those with a low or intrahepatically placed UVC. Anticoagulation treatment did not appear to have a significant effect on outcome. CONCLUSIONS: PVT occurs early in life; major risk factors in addition to the neonatal period are placement of UVC and severe neonatal sickness. Poor outcome is associated with an improperly placed UVC and with grade 3 thrombus.

Catheterization↗

Contact dermatitis and bradycardia in a preterm infant given tetracaine 4% gel.

The use of analgesics for procedural pain management in the newborn infant has been steadily increasing during the past decade. With this trend of increased analgesic utilization, there is the potential for infants to suffer from drug-induced side effects. There also is the potential to wrongfully blame drugs for all adverse events that occur during analgesic use. Two adverse events that occurred in a neonate exposed to tetracaine gel and the probability that the adverse events were caused by the drug are presented. During administration of the topical local anesthetic tetracaine for analgesia during percutaneous central venous catheter placement, a preterm infant experienced bradycardia. Several hours later, a local cutaneous reaction that progressed to skin desquamation occurred at the site. The authors assessed the probability that tetracaine caused 2 adverse events using a validated adverse drug reaction probability scale by Naranjo et al. According to the algorithm developed by Naranjo et al, it was determined that bradycardia was unlikely caused by the drug; however, the dermal reaction was probably the result of the drug.The authors determined that tetracaine caused a serious local skin reaction, but not bradycardia, in a preterm infant. This is the first report of a serious skin reaction in a neonate treated with tetracaine. Based on these findings, tetracaine gel can continue to be used to treat pain in neonates with careful evaluation of the skin.

Administration, Topical↗

Alveolar capillary dysplasia: a six-year single center experience.

UNLABELLED: Alveolar capillary dysplasia is a fatal disorder of the lung that requires lung biopsy for diagnosis. We reviewed the course of patients with alveolar capillary dysplasia following implementation of an early lung biopsy strategy between 1997-2002. We performed immunohisto-chemical studies on all tissue specimens. We diagnosed 7 cases of alveolar capillary dysplasia. We diagnosed 6/7 cases of alveolar capillary dysplasia pre-mortem by early lung biopsy. Median time between admission and lung biopsy was 6.5 days. All patients survived lung biopsy but died following withdrawal of active therapy after confirmation of the tissue diagnosis. In 1 patient we demonstrated histological findings of alveolar capillary dysplasia and congenital acinar dysplasia. Two patients were first cousins. One patient underwent pulmonary angiography with rapid filling of the pulmonary veins before passage of contrast through the capillary bed. Five patients were supported with extracorporeal membrane oxygenation and 2/5 patients survived decannulation. During the same period 8 patients required ECMO for acute hypoxic respiratory failure. Four out of 8 were diagnosed with alveolar capillary dysplasia. CONCLUSIONS: Early lung biopsy was performed with low risk and high diagnostic yield for alveolar capillary dysplasia. Alveolar capillary dysplasia occurs frequently in neonates who require ECMO support for refractory pulmonary hypertension. We have added an additional familial case and suggest a novel angiographic finding.

Biopsy↗

Wavelet analysis for neonatal electroencephalographic seizures.

Electroencepholographs (EEGs) of neonatal seizures differ from those of children and adults. This study evaluated whether wavelet transform analysis, a nonstationary frequency analysis of EEG, can recognize and characterize neonatal seizures. Twenty-second segments were analyzed from 69 EEG seizures in 15 neonatal patients whose seizures lasted 10 seconds or longer. The wavelet transform results were examined, as were EEG seizure durations and dominant frequencies. The wavelet transform results were correlated with the occurrence, after an 18-month follow-up, of postneonatal seizures. Wavelet transform analysis identified 40 seizures (58%) with a "sustained dominant frequency component" that lasted 10 seconds or longer and 29 seizures without a sustained dominant frequency component. The mean seizure duration of the 40 seizures with sustained dominant frequency components was 63.3 seconds, longer than the mean duration (33.6 seconds) of the seizures without sustained dominant frequency components, P < 0.01. Eleven patients manifested postneonatal epileptic seizures. Fifty-two EEG seizures in these 11 patients revealed more sustained dominant frequency components (74%) than 17 seizures in the 4 patients without postneonatal seizures (only 12%), P < 0.05. Wavelet transform analysis can identify neonatal EEG seizures and characterize their epileptic components. The presence of sustained dominant frequency components may predict postneonatal epileptic seizures.

Asphyxia Neonatorum↗

"Proactive" management of percutaneously inserted central catheters results in decreased incidence of infection in the ELBW population.

OBJECTIVE: Extremely low birth weight (ELBW) infants often acquire catheter-related infections (CRIs) when a percutaneously inserted central catheter (PICC) is used for parenteral nutrition or drug administration. Our objective was to compare the incidence of CRIs after we established a "PICC Maintenance Team" for the proactive management--compared to expectant management--of these lines. STUDY DESIGN: We did a prospective collection and analysis of catheter-related sepsis data over a 15-month period from February 1, 1998 through May 1, 1999. Eligible patients included all neonates weighing <1000 g at birth. RESULTS: There was a significantly decreased incidence of CRIs, to a rate of 7.1%, or 5.1/1000 catheter days (p<0.05). CONCLUSION: "Proactive" management of PICC, significantly reduced the incidence of CRIs. The reduction in infection rate is estimated to save 180 hospitalized patient days/100 very low birth weight neonates, with a concomitant savings in morbidity and medical expense.

Catheterization, Central Venous↗