Massive tissue emphysema after cardiopulmonary resuscitation.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Boris Radeleff.
Explore the source record for details and available documents.
The introduction of transjugular intrahepatic portal-systemic stent-shunt (TIPSS) has been a major breakthrough in the treatment of portal hypertension, which has evolved to a large extent, into a routine procedure. A 21-year-old male patient with progressive graft fibrosis/cirrhosis requiring TIPSS for variceal hemorrhage in the esophagus due to portal hypertension was unresponsive to conventional measures two years after living related liver transplantation (LDLT). Subsequently, variceal hemorrhage was controlled, however, liver function decreased dramatically with consecutive multi organ failure. CT scan revealed substantial necrosis in the liver. The patient underwent successful "high urgent" cadaveric liver transplantation and was discharged on postoperative d 20 in a stable condition.
Renal transplantation is accepted as the preferred treatment for most cases of end-stage renal disease. Postoperative vascular complications include stenosis or thrombosis of the transplant renal artery or arteriovenous fistulas after biopsy. Impaired arterial perfusion of the transplant may be the leading cause for graft dysfunction or refractory hypertension. Therefore, non-invasive imaging modalities are required to detect and locate vascular complications with high accuracy. Doppler ultrasound is suited as a screening method for the detection of impaired graft perfusion. Magnetic resonance imaging (MRI) is used for an accurate diagnosis of vascular complications and to support decision for appropriate surgical or interventional treatment. Minimal invasive techniques like percutaneous transluminal angioplasty and stent placement have evolved as safe procedures with a high technical success rate reducing substantial morbidity. They can be considered as an alternative to surgical treatment of transplant renal artery stenosis (TRAS). Embolization of severe arteriovenous fistulas is the method of choice if the feeding artery can be occluded through a microcatheter. In selected cases, even catheter-guided fibrinolytic treatment of arterial thrombosis might be considered, if instantaneous surgery is considered a high-risk procedure. This article reviews the imaging features of common vascular complications after renal transplantation with focus on MRI. In addition, interventional radiological techniques are described for the treatment of TRAS, acute thrombotic occlusion, and arteriovenous fistulas.
OBJECTIVE: To evaluate image quality of a large-area direct-readout flat-panel detector system in chest radiography, we conducted an observer preference study. A clinical comparative study was conducted of the flat-panel system versus the storage phosphor and standard film-screen systems. MATERIALS AND METHODS: Routine chest radiographs (posteroanterior) of 30 patients that were obtained using flat-panel, storage phosphor, and film screen systems were compared. The visibility of 10 anatomic regions and the overall image quality criteria were rated independently by three radiologists using a 5-point scale. The significance of the differences in diagnostic performance was tested with a Wilcoxon's signed rank test. Dose measurements for the three modalities were performed. RESULTS: The flat-panel radiography system showed an improved visibility in most anatomic structures when compared with a state-of-the-art conventional film-screen system and an equal visibility when compared with a storage phosphor system. The flat-panel system showed the greatest enhancement in the depiction of small detailed structures (p < 0.05) and achieved this with a reduction in overall radiation dose of more than 50%. CONCLUSION: The visibility of anatomic structures provided by this flat-panel detector system is as good as if not better than that provided by conventional or storage phosphor systems while emitting a reduced radiation dose.
OBJECTIVE: The objective of this study was to compare clinical chest radiographs of a large-area, flat-panel digital radiography system and a conventional film-screen radiography system. The comparison was based on an observer preference study of image quality and visibility of anatomic structures. MATERIALS AND METHODS: Routine follow-up chest radiographs were obtained from 100 consecutive oncology patients using a large-area, amorphous silicon flat-panel detector digital radiography system (dose equivalent to a 400-speed film system). Hard-copy images were compared with previous examinations of the same individuals taken on a conventional film-screen system (200-speed). Patients were excluded if changes in the chest anatomy were detected or if the time interval between the examinations exceeded 1 year. Observer preference was evaluated for the image quality and the visibility of 15 anatomic structures using a five-point scale. RESULTS: Dose measurements with a chest phantom showed a dose reduction of approximately 50% with the digital radiography system compared with the film-screen radiography system. The image quality and the visibility of all but one anatomic structure of the images obtained with the digital flat-panel detector system were rated significantly superior (p < or = 0.0003) to those obtained with the conventional film-screen radiography system. CONCLUSION: The image quality and visibility of anatomic structures on the images obtained by the flat-panel detector system were perceived as equal or superior to the images from conventional film-screen chest radiography. This was true even though the radiation dose was reduced approximately 50% with the digital flat-panel detector system.
We report a rare case of two communicating pseudoaneurysms of the common hepatic artery 1 month postoperatively following pylorus-preserving pancreaticoduodenectomy due an abscess formation. We describe the superselective transcatheteral embolization technique with deployment of interlocking detachable coils and Histoacryl-Lipiodol in this case and discuss the recent literature. Despite the technical success by achieving hemodynamic stability with initial preservation of liver function, the patient died 23 days postembolization due to multiorgan failure.
Liver transplantation (LT) in an adult with situs inversus (SI) is extremely rare and requires precise pre-operative management. A 48-yr-old male with SI suffering from alcoholic liver cirrhosis underwent LT at our institution in March 2003. Pre-operatively, liver anatomy was determined by CT scan, three-dimensional liver reconstruction and angiography. LT was performed using the Belghiti technique with side-to-side cavo-caval anastomosis, transplanting a graft from a donor with normal anatomy. Post-operatively, the patient recovered without major complications, except an epileptic event because of a central pontine myelinolysis, and he was discharged on the 25th post-operative day. Three months after surgery, the T-drain placed intra-operatively into the donor bile duct was removed; transplant perfusion and function were stable with an actual follow-up period of 24 months. LT in patients with SI is feasible. Pre-operative imaging with three-dimensional reconstruction is a beneficial tool for operation planning in patients with rare anatomic variations.