Differential pH measurements of metabolic cellular activity in nl culture volumes using microfabricated iridium oxide electrodes.

In this paper we describe a new approach to measure pH differences in microfluidic devices and demonstrated acidification rate measurements in on-chip cell culture systems with nl wells. We use two miniaturized identical iridium oxide (IrOx) thin film electrodes (20 micromx400 microm), one as a quasi-reference electrode, the other as a sensing electrode, placed in two confluent compartments on chip. The IrOx electrodes were deposited onto microfabricated platinum (Pt) electrodes simultaneously using electrodeposition. Incorporating the electrodes into a microfluidic device allowed us to expose each electrode to a different solution with a pH difference of one pH unit maintaining a confluent connection between the electrodes. In this configuration, we obtained a reproducible voltage difference between the two IrOx thin film electrodes, which corresponds to the electrode sensitivities of -70 mV/pH at 22 degrees C. In order to measure the acidification rate of cells in nl cell culture volumes we placed one IrOx thin film electrode in the perfusion channel as a quasi-reference electrode and the other in the cell culture volume. We obtained an acidification rate of 0.19+/-0.02 pH/min for fibroblast cells using a stop flow protocol. These results show that we can use two identical miniaturized microfabricated IrOx electrodes to measure pH differences to monitor the metabolic activity of cell cultures on chip. Furthermore, our approach can also be applied in biosensor or bioanalytical applications.

Animals↗

Thin-film IrOx pH microelectrode for microfluidic-based microsystems.

Microsensors are valuable tools to monitor cell metabolism in cell culture volumes. The present research describes the fabrication and characterization of on-chip thin-film iridium oxide pH microsensors with dimensions of 20 microm x 20 microm and 20 microm x 40 microm suitable to be incorporated into nl volumes. IrOx thin films were formed on platinum microelectrodes by electrochemical deposition in galvanostatic mode. Anodically grown iridium oxide films showed a near super-Nernstian response with a slope of -77.6+/-2 mV/pH at 22 degrees C, and linear responses within the pH range of 4-11. Freshly deposited electrodes showed response times as low as 6s. Long-term studies showed a baseline drift of 2-3 mV/month, which could easily be compensated by calibration. This work demonstrated for the first time the use of planar IrOx pH microelectrodes to measure the acidification rate of CHO and fibroblast cells in an on chip cell culture volume of 25 nl with microfluidic control.

Animals↗