Evaluation of similarity measures for reconstruction-based registration in image-guided radiotherapy and surgery.

PURPOSE: A promising patient positioning technique is based on registering computed tomographic (CT) or magnetic resonance (MR) images to cone-beam CT images (CBCT). The extra radiation dose delivered to the patient can be substantially reduced by using fewer projections. This approach results in lower quality CBCT images. The purpose of this study is to evaluate a number of similarity measures (SMs) suitable for registration of CT or MR images to low-quality CBCTs. METHODS AND MATERIALS: Using the recently proposed evaluation protocol, we evaluated nine SMs with respect to pretreatment imaging modalities, number of two-dimensional (2D) images used for reconstruction, and number of reconstruction iterations. The image database consisted of 100 X-ray and corresponding CT and MR images of two vertebral columns. RESULTS: Using a higher number of 2D projections or reconstruction iterations results in higher accuracy and slightly lower robustness. The similarity measures that behaved the best also yielded the best registration results. The most appropriate similarity measure was the asymmetric multi-feature mutual information (AMMI). CONCLUSIONS: The evaluation protocol proved to be a valuable tool for selecting the best similarity measure for the reconstruction-based registration. The results indicate that accurate and robust CT/CBCT or even MR/CBCT registrations are possible if the AMMI similarity measure is used.

Algorithms↗

Intensity inhomogeneity correction of multispectral MR images.

Intensity inhomogeneity in MR images is an undesired phenomenon, which often hampers different steps of quantitative image analysis such as segmentation or registration. In this paper, we propose a novel fully automated method for retrospective correction of intensity inhomogeneity. The basic assumption is that inhomogeneity correction could be improved by integrating spatial and intensity information from multiple MR channels, i.e., T1, T2, and PD weighted images. Intensity inhomogeneities of such multispectral images are removed simultaneously in a four-step iterative procedure. First, the probability distribution of image intensities and corresponding spatial features is calculated. In the second step, intensity correction forces that tend to minimize joint entropy of multispectral image are estimated for all image voxels. Third, independent inhomogeneity correction fields are obtained for each channel by regularization and normalization of voxel forces, and last, corresponding partial inhomogeneity corrections are performed separately for each channel. The method was quantitatively evaluated on simulated and real MR brain images and compared to three other methods.

Brain↗

3-D/2-D registration by integrating 2-D information in 3-D.

In image-guided therapy, high-quality preoperative images serve for planning and simulation, and intraoperatively as "background", onto which models of surgical instruments or radiation beams are projected. The link between a preoperative image and intraoperative physical space of the patient is established by image-to-patient registration. In this paper, we present a novel 3-D/2-D registration method. First, a 3-D image is reconstructed from a few 2-D X-ray images and next, the preoperative 3-D image is brought into the best possible spatial correspondence with the reconstructed image by optimizing a similarity measure (SM). Because the quality of the reconstructed image is generally low, we introduce a novel SM, which is able to cope with low image quality as well as with different imaging modalities. The novel 3-D/2-D registration method has been evaluated and compared to the gradient-based method (GBM) using standardized evaluation methodology and publicly available 3-D computed tomography (CT), 3-D rotational X-ray (3DRX), and magnetic resonance (MR) and 2-D X-ray images of two spine phantoms, for which gold standard registrations were known. For each of the 3DRX, CT, or MR images and each set of X-ray images, 1600 registrations were performed from starting positions, defined as the mean target registration error (mTRE), randomly generated and uniformly distributed in the interval of 0-20 mm around the gold standard. The capture range was defined as the distance from gold standard for which the final TRE was less than 2 mm in at least 95% of all cases. In terms of success rate, as the function of initial misalignment and capture range the proposed method outperformed the GBM. TREs of the novel method and the GBM were approximately the same. For the registration of 3DRX and CT images to X-ray images as few as 2-3 X-ray views were sufficient to obtain approximately 0.4 mm TREs, 7-9 mm capture range, and 80%-90% of successful registrations. To obtain similar results for MR to X-ray registrations, an image, reconstructed from at least 11 X-ray images was required. Reconstructions from more than 11 images had no effect on the registration results.

Algorithms↗

A protocol for evaluation of similarity measures for rigid registration.

The accuracy and robustness of a registration method depend on a number of factors, such as imaging modality, image content and image degrading effects, the class of spatial transformation used for registration, similarity measure, optimization, and numerous implementation details. The complex interdependence of these factors makes the assessment of the influence of a particular factor on registration difficult, although it is often desirable to have some estimate of such influences prior to registration. The similarity measure used to create the cost function is one of the factors that most influences the quality of registration. Traditionally, limited information on the behavior of a similarity measure is obtained either by studying the quality of the final registration or by drawing plots of similarity measure values obtained by translating or rotating one image relative to the "gold standard." In this paper, we present a protocol for a more thorough, optimization-independent, and systematic statistical evaluation of similarity measures. This protocol estimates a similarity measure's capture range, the number, location and extent of local optima, and the accuracy and distinctiveness of the global optimum. To show that the proposed evaluation protocol is viable, we have conducted several experiments with nine similarity measures and real computed tomography and magnetic resonance (MR) images of a spine phantom, MR brain images, and MR and positron emission tomography brain images, for which "gold standard" registrations were available. We have also studied the impact of histogram bin size on the behavior of nine similarity measures. The proposed evaluation protocol is useful for selecting the best similarity measure and corresponding optimization method for a particular application, as well as for studying the influence of sampling, interpolation, histogram bin size, partial image overlap, and image degradation, such as noise, intensity inhomogeneity, and geometrical distortions on the behavior of a similarity measure.

Algorithms↗

The impact of image information on compressibility and degradation in medical image compression.

The aim of the study was to demonstrate and critically discuss the influence of image information on compressibility and image degradation. The influence of image information on image compression was demonstrated on the axial computed tomography images of a head. The standard Joint Photographic Expert Group (JPEG) and JPEG 2000 compression methods were used in compression ratio (CR) and in quality factor (QF) compression modes. Image information was estimated by calculating image entropy, while the effects of image compression were evaluated quantitatively, by file size reduction and by local and global mean square error (MSE), and qualitatively, by visual perception of distortion in high and low contrast test patterns. In QF compression mode, a strong correlation between image entropy and file size was found for JPEG (r=0.87, p < 0.001) and JPEG 2000 (r=0.84, p < 0.001), while corresponding local MSE was constant (4.54) or nearly constant (2.36-2.37), respectively. For JPEG 2000 CR compression mode, CR was nearly constant (1:25), while local MSE varied considerably (2.26 and 10.09). The obtained qualitative and quantitative results clearly demonstrate that image degradation highly depends on image information, which indicates that the degree of image degradation cannot be guaranteed in CR but only in QF compression mode. CR is therefore not a measure of choice for expressing the degree of image degradation in medical image compression. Moreover, even when using QF compression modes, objective evaluation, and comparison of the compression methods within and between studies is often not possible due to the lack of standardization of compression quality scales.

Algorithms↗

Automated curved planar reformation of 3D spine images.

Traditional techniques for visualizing anatomical structures are based on planar cross-sections from volume images, such as images obtained by computed tomography (CT) or magnetic resonance imaging (MRI). However, planar cross-sections taken in the coordinate system of the 3D image often do not provide sufficient or qualitative enough diagnostic information, because planar cross-sections cannot follow curved anatomical structures (e.g. arteries, colon, spine, etc). Therefore, not all of the important details can be shown simultaneously in any planar cross-section. To overcome this problem, reformatted images in the coordinate system of the inspected structure must be created. This operation is usually referred to as curved planar reformation (CPR). In this paper we propose an automated method for CPR of 3D spine images, which is based on the image transformation from the standard image-based to a novel spine-based coordinate system. The axes of the proposed spine-based coordinate system are determined on the curve that represents the vertebral column, and the rotation of the vertebrae around the spine curve, both of which are described by polynomial models. The optimal polynomial parameters are obtained in an image analysis based optimization framework. The proposed method was qualitatively and quantitatively evaluated on five CT spine images. The method performed well on both normal and pathological cases and was consistent with manually obtained ground truth data. The proposed spine-based CPR benefits from reduced structural complexity in favour of improved feature perception of the spine. The reformatted images are diagnostically valuable and enable easier navigation, manipulation and orientation in 3D space. Moreover, reformatted images may prove useful for segmentation and other image analysis tasks.

Humans↗

Reconstruction-based 3D/2D image registration.

In this paper we present a novel 3D/2D registration method, where first, a 3D image is reconstructed from a few 2D X-ray images and next, the preoperative 3D image is brought into the best possible spatial correspondence with the reconstructed image by optimizing a similarity measure. Because the quality of the reconstructed image is generally low, we introduce a novel asymmetric mutual information similarity measure, which is able to cope with low image quality as well as with different imaging modalities. The novel 3D/2D registration method has been evaluated using standardized evaluation methodology and publicly available 3D CT, 3DRX, and MR and 2D X-ray images of two spine phantoms, for which gold standard registrations were known. In terms of robustness, reliability and capture range the proposed method outperformed the gradient-based method and the method based on digitally reconstructed radiographs (DRRs).

Algorithms↗

MRI intensity inhomogeneity correction by combining intensity and spatial information.

We propose a novel fully automated method for retrospective correction of intensity inhomogeneity, which is an undesired phenomenon in many automatic image analysis tasks, especially if quantitative analysis is the final goal. Besides most commonly used intensity features, additional spatial image features are incorporated to improve inhomogeneity correction and to make it more dynamic, so that local intensity variations can be corrected more efficiently. The proposed method is a four-step iterative procedure in which a non-parametric inhomogeneity correction is conducted. First, the probability distribution of image intensities and corresponding second derivatives is obtained. Second, intensity correction forces, condensing the probability distribution along the intensity feature, are computed for each voxel. Third, the inhomogeneity correction field is estimated by regularization of all voxel forces, and fourth, the corresponding partial inhomogeneity correction is performed. The degree of inhomogeneity correction dynamics is determined by the size of regularization kernel. The method was qualitatively and quantitatively evaluated on simulated and real MR brain images. The obtained results show that the proposed method does not corrupt inhomogeneity-free images and successfully corrects intensity inhomogeneity artefacts even if these are more dynamic.

Algorithms↗

"Gold standard" data for evaluation and comparison of 3D/2D registration methods.

Evaluation and comparison of registration techniques for image-guided surgery is an important problem that has received little attention in the literature. In this paper we address the challenging problem of generating reliable "gold standard" data for use in evaluating the accuracy of 3D/2D registrations. We have devised a cadaveric lumbar spine phantom with fiducial markers and established highly accurate correspondences between 3D CT and MR images and 18 2D X-ray images. The expected target registration errors for target points on the pedicles are less than 0.26 mm for CT-to-X-ray registration and less than 0.42 mm for MR-to-X-ray registration. As such, the "gold standard" data, which has been made publicly available on the Internet (http://lit.fe.uni-lj.si/Downloads/downloads.asp), is useful for evaluation and comparison of 3D/2D image registration methods.

Aged↗

3-D/2-D registration of CT and MR to X-ray images.

A crucial part of image-guided therapy is registration of preoperative and intraoperative images, by which the precise position and orientation of the patient's anatomy is determined in three dimensions. This paper presents a novel approach to register three-dimensional (3-D) computed tomography (CT) or magnetic resonance (MR) images to one or more two-dimensional (2-D) X-ray images. The registration is based solely on the information present in 2-D and 3-D images. It does not require fiducial markers, intraoperative X-ray image segmentation, or timely construction of digitally reconstructed radiographs. The originality of the approach is in using normals to bone surfaces, preoperatively defined in 3-D MR or CT data, and gradients of intraoperative X-ray images at locations defined by the X-ray source and 3-D surface points. The registration is concerned with finding the rigid transformation of a CT or MR volume, which provides the best match between surface normals and back projected gradients, considering their amplitudes and orientations. We have thoroughly validated our registration method by using MR, CT, and X-ray images of a cadaveric lumbar spine phantom for which "gold standard" registration was established by means of fiducial markers, and its accuracy assessed by target registration error. Volumes of interest, containing single vertebrae L1-L5, were registered to different pairs of X-ray images from different starting positions, chosen randomly and uniformly around the "gold standard" position. CT/X-ray (MR/ X-ray) registration, which is fast, was successful in more than 91% (82% except for L1) of trials if started from the "gold standard" translated or rotated for less than 6 mm or 17 degrees (3 mm or 8.6 degrees), respectively. Root-mean-square target registration errors were below 0.5 mm for the CT to X-ray registration and below 1.4 mm for MR to X-ray registration.

Humans↗