PubMed Health⌕ Search

Biomedical subjects

Bradley J Beattie

Publications and source records attributed to Bradley J Beattie.

3 recordsLinked to original sources

Binary state pattern clustering: a digital paradigm for class and biomarker discovery in gene microarray studies of cancer.

Class and biomarker discovery continue to be among the preeminent goals in gene microarray studies of cancer. We have developed a new data mining technique, which we call Binary State Pattern Clustering (BSPC) that is specifically adapted for these purposes, with cancer and other categorical datasets. BSPC is capable of uncovering statistically significant sample subclasses and associated marker genes in a completely unsupervised manner. This is accomplished through the application of a digital paradigm, where the expression level of each potential marker gene is treated as being representative of its discrete functional state. Multiple genes that divide samples into states along the same boundaries form a kind of gene-cluster that has an associated sample-cluster. BSPC is an extremely fast deterministic algorithm that scales well to large datasets. Here we describe results of its application to three publicly available oligonucleotide microarray datasets. Using an alpha-level of 0.05, clusters reproducing many of the known sample classifications were identified along with associated biomarkers. In addition, a number of simulations were conducted using shuffled versions of each of the original datasets, noise-added datasets, as well as completely artificial datasets. The robustness of BSPC was compared to that of three other publicly available clustering methods: ISIS, CTWC and SAMBA. The simulations demonstrate BSPC's substantially greater noise tolerance and confirm the accuracy of our calculations of statistical significance.

Algorithms↗

Possible axonal regrowth in late recovery from the minimally conscious state.

We used diffusion tensor imaging (DTI) to study 2 patients with traumatic brain injury. The first patient recovered reliable expressive language after 19 years in a minimally conscious state (MCS); the second had remained in MCS for 6 years. Comparison of white matter integrity in the patients and 20 normal subjects using histograms of apparent diffusion constants and diffusion anisotropy identified widespread altered diffusivity and decreased anisotropy in the damaged white matter. These findings remained unchanged over an 18-month interval between 2 studies in the first patient. In addition, in this patient, we identified large, bilateral regions of posterior white matter with significantly increased anisotropy that reduced over 18 months. In contrast, notable increases in anisotropy within the midline cerebellar white matter in the second study correlated with marked clinical improvements in motor functions. This finding was further correlated with an increase in resting metabolism measured by PET in this subregion. Aberrant white matter structures were evident in the second patient's DTI images but were not clinically correlated. We propose that axonal regrowth may underlie these findings and provide a biological mechanism for late recovery. Our results are discussed in the context of recent experimental studies that support this inference.

Adolescent↗

Quantitative imaging of bromine-76 and yttrium-86 with PET: a method for the removal of spurious activity introduced by cascade gamma rays.

Positron Emission Tomography of bromine-76 and yttrium-86 results in the detection of coincident events that are not strictly associated with annihilation photon pairs. Instead, these coincidences occur because prompt gamma rays emitted by these nuclides result in cascades of photons that are emitted within the timing window of the PET scanner. Pairs of detected photons from these cascades are not angularly correlated and therefore contain little information regarding the location of their source. Furthermore, these coincidences are not removed by correction procedures (e.g., randoms, scatter) routinely applied to PET data. If left uncorrected, the cascade coincidences will result in spurious apparent activity within the PET images. A correction, applied within projection space, that removes the cascade coincidence signal from septa-in (i.e., two-dimensional) datasets is proposed and tested on phantom data.

Algorithms↗