Fraunhofer effect atomic absorption spectrometry.

The dark lines in the solar spectrum were discovered by Wollaston and cataloged by Fraunhofer in the early days of the 19th century. Some years later, Kirchhoff explained the appearance of the dark lines: the sun was acting as a continuum light source and metals in the ground state in its atmosphere were absorbing characteristic narrow regions of the spectrum. This discovery eventually spawned atomic absorption spectrometry, which became a routine technique for chemical analysis in the mid-20th century. Laboratory-based atomic absorption spectrometers differ from the original observation of the Fraunhofer lines because they have always employed a separate light source and atomizer. This article describes a novel atomic absorption device that employs a single source, the tungsten coil, as both the generator of continuum radiation and the atomizer of the analytes. A 25-microL aliquot of sample is placed on the tungsten filament removed from a commercially available 150-W light bulb. The solution is dried and ashed by applying low currents to the coil in a three-step procedure. Full power is then applied to the coil for a brief period. During this time, the coil produces white light, which may be absorbed by any metals present in the atomization cloud produced by the sample. A high-resolution spectrometer with a charge-coupled device detector monitors the emission spectrum of the coil, which includes the dark lines from the metals. Detection limits are reported for seven elements: 5 pg of Ca (422.7 nm); 2 ng of Co (352.7 nm); 200 pg of Cr (425.4 nm); 7 pg of Sr (460.7 nm); 100 pg of Yb (398.8 nm); 500 pg of Mn (403.1 nm); and 500 pg of K (404.4 nm). Simultaneous multielement analyses are possible within a 4-nm spectral window. The relative standard deviations for the seven metals are below 8% for all metals except for Ca (10.7%), which was present in the blank at measurable levels. Analysis of a standard reference material (drinking water) resulted in a mean percent recovery of 91%. This report attempts to give an historical perspective on the development of a novel atomic spectrometer based on the Fraunhofer effect.

Journal Article↗

Analytical characteristics of a continuum-source tungsten coil atomic absorption spectrometer.

A continuum-source tungsten coil electrothermal atomic absorption spectrometer has been assembled, evaluated, and employed in four different applications. The instrument consists of a xenon arc lamp light source, a tungsten coil atomizer, a Czerny-Turner high resolution monochromator, and a linear photodiode array detector. This instrument provides simultaneous multi-element analyses across a 4 nm spectral window with a resolution of 0.024 nm. Such a device might be useful in many different types of analyses. To demonstrate this broad appeal, four very different applications have been evaluated. First of all, the temperature of the gas phase was measured during the atomization cycle of the tungsten coil, using tin as a thermometric element. Secondly, a summation approach for two absorption lines for aluminum falling within the same spectral window (305.5-309.5 nm) was evaluated. This approach improves the sensitivity without requiring any additional preconcentration steps. The third application describes a background subtraction technique, as it is applied to the analysis of an oil emulsion sample. Finally, interference effects caused by Na on the atomization of Pb were studied. The simultaneous measurements of Pb and Na suggests that negative interference arises at least partially from competition between Pb and Na atoms for H2 in the gas phase.

Journal Article↗

Role of zinc and iron chelation in apoptosis mediated by tachpyridine, an anti-cancer iron chelator.

Tachpyridine (N,N',N"-tris(2-pyridylmethyl)-cis,cis-1,3,5-triaminocyclohexane; tachpyr) is a potent hexadentate iron chelator under preclinical investigation as a potential anti-cancer agent. Tachpyridine induces apoptosis in cultured cancer cells by triggering a mitochondrial pathway of cell death that is p53-independent. To explore the relationship between the chelation chemistry of tachpyridine and its biological activity, a sensitive and specific reversed-phase high-performance liquid chromatography (RP-HPLC) method was devised and used to measure tachpyr and its metal complexes in cells and tissue culture media. Major species identified in cells treated with tachpyr were tachpyr itself, [Zn(tachpyr)](2+), and iron coordinated to two partially oxidized species of tachpyridine, [Fe(tachpyr-ox-2)](2+), and [Fe(tachpyr-ox-4)](2+). The kinetics of intracellular accumulation of [Zn(tachpyr)](2+) and [Fe(tachpyr-ox-2)](2+) were markedly different: [Zn(tachpyr)](2+) rapidly reached plateau levels, whereas intracellular levels of [Fe(tachpyr-ox-2)](2+) and free tachpyr rose steadily. At the last timepoint measured, 9% of total cellular iron and 13% of total cellular zinc were bound by tachpyridine. Taken together, [Zn(tachpyr)](2+), [Fe(tachpyr-ox-2)](2+), and free tachpyr accounted for virtually all of the tachpyr added, indicating that iron and zinc are the principal metals targeted by tachpyridine in cells. Consistent with these findings, activation of the apoptotic caspases 9 and 3 was blocked in cells pre-treated with either iron or zinc. Pretreatment with either of these metals also completely protected cells from the cytotoxic effects of tachpyridine. These results demonstrate a link between metal depletion and chelator cytotoxicity, and suggest that intracellular chelation of zinc as well as iron may play a role in the cytotoxicity of tachpyridine.

Apoptosis↗

Determination of trace metals in drinking water using solid-phase extraction disks and X-ray fluorescence spectrometry.

A convenient method is described for monitoring Cd, Ni, Cu, and Pb at trace levels in drinking water samples. These metals are preconcentrated on a chelating solid-phase extraction disk and then determined by X-ray fluorescence spectrometry. The method tolerates a wide pH range (pH 6-14) and a large amount of alkaline and alkaline earth elements. The preconcentration factor is well over 1600, assuming a 1 L water sample volume. The limits of detection for Cd, Ni, Cu, and Pb are 3.8, 0.6, 0.4, and 0.3 ng/mL, respectively. These are well below the federal maximum contaminant level values, which are 5, 100, 1300, and 15 ng/mL, respectively. The proposed method has many advantages including ease of operation, multielement capability, nondestructiveness, high sensitivity, and relative cost efficiency. The solid-phase extraction step can be conducted in the field and then the disks can be mailed to a laboratory for the analysis, eliminating the cost of transporting large volumes of water samples. Furthermore, the color of the used extraction disk provides an initial estimate of the degree of contamination for some transition metals (for example, Ni and Cu). Thus, the overall cost for analysis of metals in drinking water can be minimized by implementing the method, and small water supply companies with limited budgets will be better able to comply with the Safe Drinking Water Act.

Chromatography↗

Multi-analyte calibration curve for high-performance liquid chromatography with an inductively coupled plasma carbon emission detector.

A liquid chromatography system with an inductively coupled plasma detector is used to prepare a single calibration curve that is useful for multiple analytes. The detector monitors the atomic emission from carbon at 193.09 nm. Hence, the analytes need not exhibit appreciable molar absorptivity or native fluorescence. Since the carbon signal is independent of molecular structure, the sensitivities for different compounds are similar as long as nebulization efficiencies are comparable. In fact, with a suitable internal standard, no calibration curve is necessary. The capability of the system is demonstrated with a test mixture of nine amino acids separated with a C30 reversed-phase column and a 20 mM phosphate buffered mobile phase. The system provides a detection limit of 30 ng carbon. A multi-analyte calibration curve is prepared with 135 distinct measurements: each of nine analytes, at five different concentrations, repeated in triplicate. The average relative standard deviation for 27 measurements of different amino acids at a given concentration is 2.5%. Clearly, a single analyte will suffice for the calibration of all nine test compounds. Similarly, the internal standard method provides an average percent error of 2.0% for the determination of 45 different amino acid concentrations using only a single replicate for each sample.

Amino Acids↗