Brage H Amundsen

Publications and source records attributed to Brage H Amundsen.

4 recordsLinked to original sources

Noninvasive myocardial strain measurement by speckle tracking echocardiography: validation against sonomicrometry and tagged magnetic resonance imaging.

OBJECTIVES: The aim of this study was to validate speckle tracking echocardiography (STE) as a method for angle-independent measurement of regional myocardial strain, using sonomicrometry and magnetic resonance imaging (MRI) tagging as reference methods. BACKGROUND: Tissue Doppler imaging allows non-invasive measurement of myocardial strain in the left ventricle (LV), but is limited by angle dependency. METHODS: Strain measurements with STE were obtained by a custom-made program that allowed tracking of two-dimensional motion of speckle patterns in a B-mode image. In anesthetized dogs, we compared LV long- and short-axis measurements by STE to sonomicrometry during preload changes and regional myocardial ischemia. Measurements in the two orthogonal axes were obtained simultaneously in a single imaging plane. In human subjects, long-axis strain by STE and MRI tagging were compared in multiple segments of the LV. RESULTS: In the experimental study there was good correlation and agreement between STE and sonomicrometry for systolic strain in the long axis (r = 0.90, p < 0.001; 95% limits of agreement -4.4% to 5.0%) and systolic shortening in the short axis (r = 0.79, p < 0.001; -5.6% to 5.1%). In the clinical study, 80% of the segments could be analyzed, and correlation and agreement between STE and MRI tagging were good (r = 0.87, p < 0.001; -9.1% to 8.0%). CONCLUSIONS: Speckle tracking echocardiography provides accurate and angle-independent measurements of LV dimensions and strains and has potential to become a clinical bedside tool for quantifying myocardial strain.

Adult↗

New noninvasive method for assessment of left ventricular rotation: speckle tracking echocardiography.

BACKGROUND: Left ventricular (LV) torsion is due to oppositely directed apical and basal rotation and has been proposed as a sensitive marker of LV function. In the present study, we introduce and validate speckle tracking echocardiography (STE) as a method for assessment of LV rotation and torsion. METHODS AND RESULTS: Apical and basal rotation by STE was measured from short-axis images by automatic frame-to-frame tracking of gray-scale speckle patterns. Rotation was calculated as the average angular displacement of 9 regions relative to the center of a best-fit circle through the same regions. As reference methods we used sonomicrometry in anesthetized dogs during baseline, dobutamine infusion, and apical ischemia, and magnetic resonance imaging (MRI) tagging in healthy humans. In dogs, the mean peak apical rotation was -3.7+/-1.2 degrees (+/-SD) and -4.1+/-1.2 degrees, and basal rotation was 1.9+/-1.5 degrees and 2.0+/-1.2 degrees by sonomicrometry and STE, respectively. Rotations by both methods increased (P<0.001) during dobutamine infusion. Apical rotation by both methods decreased during left anterior descending coronary artery occlusion (P<0.007), whereas basal rotation was unchanged. In healthy humans, apical rotation was -11.6+/-3.8 degrees and -10.9+/-3.3 degrees, and basal rotation was 4.8+/-1.7 degrees and 4.6+/-1.3 degrees by MRI tagging and STE, respectively. Torsion measurement by STE showed good correlation and agreement with sonomicrometry (r=0.94, P<0.001) and MRI (r=0.85, P<0.001). CONCLUSIONS: The present study demonstrates that regional LV rotation and torsion can be measured accurately by STE, suggesting a new echocardiographic approach for quantification of LV systolic function.

Animals↗

Effective training for patients with intermittent claudication.

OBJECTIVE: Current guidelines for treatment of intermittent claudication (IC) do not include a specific recommendation for the intensity of exercise therapy. Thus, the purpose of this study was to determine the relative effectiveness of high versus low intensity exercise for patients with IC, and further to study the effect of such training on blood flow to the legs during exercise. DESIGN: The effect of eight weeks of supervised endurance training was examined in 16 patients with IC. The patients were randomly assigned to training at intensities corresponding to either 60% or 80% of their peak oxygen consumption (VO2peak), respectively. RESULTS: VO2peak and time to exhaustion increased significantly (9% and 16%, respectively) more in the high intensity group (p<0.05). Blood flow to the legs did not change after training in any of the groups. CONCLUSION: High intensity training gave larger improvements in VO2peak and time to exhaustion than low intensity training. As blood flow did not change after the exercise program, it is likely that the observed different increase of VO2peak was due to changed mitochondrial oxidative capacity and/or skeletal muscle diffusive capacity.

Aged↗

Ultrasound recorded axillary artery blood flow during elbow-flexion exercise.

PURPOSE: To characterize and evaluate the repeatability of ultrasound recorded blood flow in the axillary artery during one-arm dynamic elbow flexion. METHOD: 11 healthy women (23 +/- 0.9 yr, 168 +/- 1.7 cm, 63 +/- 1.1 kg) performed 90 degrees elbow flexion in supine position. Mean maximum blood velocity was recorded by ultrasound during and after two submaximal loads, representing 16 and 24% of maximal voluntary contraction, and after exhaustion (.VO(2peak))Axillary artery diameter was measured after each workload. Each subject was examined two times 8 wk apart. Oxygen uptake was measured during exercise. Values are mean +/- SE. RESULTS: Flow was not different in the two tests. Flow was 25% higher immediately after than during exercise at the submaximal workloads. Flow immediately after .VO(2peak) was 1420 +/- 79 mL.min(-1). Axillary artery diameter after .VO(2peak) was 8% larger than at rest. Coefficient of variation ranged from 11 to 23%, coefficient of repeatability ranged from 230 mL.min(-1) at rest to 940 mL.min(-1) after exercise. Coefficient of repeatability for artery diameter was 0.09 cm; coefficient of variation for diameter was about 4% at all recording times. CONCLUSION: The present study showed that ultrasound recordings of blood flow during dynamic elbow-flexion exercise were reproducible. The method can be used to study training-induced flow changes and can detect differences of about 130 mL.min(-1). Artery diameter seemed to increase as flow and load increased.

Adult↗