PubMed Health⌕ Search

Biomedical subjects

Brandon T Ruotolo

Publications and source records attributed to Brandon T Ruotolo.

17 recordsLinked to original sources

Mass measurements of increased accuracy resolve heterogeneous populations of intact ribosomes.

It is established that noncovalent complexes can be maintained both during and after electrospray and that assemblies of increasing size and complexity often lead to broadened peaks in mass spectra. This broadening arises from the tendency of large protein assemblies to form adducts with salts and is compounded when complexes are isolated directly from cells, without the full protein complement. To investigate the origins of this broadening in mass spectral peaks and to develop the optimal method for analyzing mass spectra of large protein complexes, we have carried out a systematic investigation of a series of noncovalent complexes representing a range of different sizes and architectures. We establish a positive correlation between peak width and the increased mass observed and show that this correlation is independent of the instrumental parameters employed. Using this relationship we show that we can determine masses of both 30S subunits and intact 2.3 MDa 70S ribosomes from Thermus thermophilus. The masses of both particles are consistent with multiple populations of ribosomes. To identify these various populations we combine simulated mass spectra of ribosomes, with and without the full protein complement, and estimate the extent of adducts from our study of known complexes. The results allow us to determine the contribution of the different subpopulations to the overall mass spectrum. We confirm the existence of these subpopulations using tandem mass spectrometry of intact 30S subunits. Overall, the results show that, rather than uniform particles, gas-phase ribosomes consist of a number of discrete populations. More generally, the results establish a rigorous procedure for accurate mass measurement and spectral analysis of heterogeneous macromolecular assemblies.

Models, Molecular↗

Aspects of native proteins are retained in vacuum.

It is now well established that protein complexes can be maintained in the gas phase, under the reduced pressure conditions experienced within mass spectrometers. This remains an intriguing phenomenon, given the importance placed on water molecules in stabilizing protein structure. As a consequence, the overall structure of protein molecules and their complexes in the gas phase continues to stimulate much research. The eventual outcomes of this research will not only increase the number of applications of mass spectrometry to structural biology, but will also enhance our understanding of the interactions important for maintaining protein complexes in the absence of bulk solvent.

Mass Spectrometry↗

Structural basis for the inhibition of activin signalling by follistatin.

The secreted, multidomain protein follistatin binds activins with high affinity, inhibiting their receptor interaction. We have dissected follistatin's domain structure and shown that the minimal activin-inhibiting fragment of follistatin is comprised of the first and second Fs domains (Fs12). This protein can bind to activin dimer and form a stable complex containing two Fs12 molecules and one activin dimer. We have solved crystal structures of activin A alone and its complex with Fs12 fragment to 2 A resolution. The complex structure shows how Fs12 molecules wrap around the back of the 'wings' of activin, blocking the type II receptor-binding site on activin A. Arginine 192 in Fs2 is a key residue in this interaction, inserting itself in between activin's fingers. Complex formation imposes a novel orientation for the EGF- and Kazal-like subdomains in the Fs2 domain and activin A shows further variation from the canonical TGF-beta family fold. The structure provides a detailed description of the inhibitory mechanism and gives insights into interactions of follistatin with other TGF-beta family proteins.

Activin Receptors, Type II↗

Tandem mass spectrometry reveals the quaternary organization of macromolecular assemblies.

The application of mass spectrometry (MS) to the study of progressively larger and more complex macromolecular assemblies is proving increasingly useful for structural biologists. The scope of this approach has recently been widened through the application of a tandem MS procedure. This two-step technique involves the selection of specific assemblies in the gas phase and inducing their dissociation through collisions with argon atoms. Here, we investigate the mechanism of this process and show that dissociation of subunits from a macromolecular assembly follows a sequential pathway, with the partitioning of charge between the dissociation products governed primarily by their relative surface areas. Using this basis of understanding, we highlight differences in the dissociation pathways of three related macromolecular assemblies and show how these are a direct consequence of changes in both local and global oligomeric organization.

Animals↗

Evidence for macromolecular protein rings in the absence of bulk water.

We have examined the architecture of a protein complex in the absence of bulk water. By determining collision cross sections of assemblies of the trp RNA binding protein, TRAP, we established that the 11-membered ring topology of the complex can be maintained within a mass spectrometer. We also found that the binding of tryptophan enhances the stability of the ring structure and that addition of a specific RNA molecule increases the size of the complex and prevents structural collapse. These results provide definitive evidence that protein quaternary structure can be maintained in the absence of bulk water and highlight the potential of ion mobility separation for defining shapes of heterogeneous macromolecular assemblies.

5' Untranslated Regions↗

Characterization of symmetric complexes of nerve growth factor and the ectodomain of the pan-neurotrophin receptor, p75NTR.

Nerve growth factor (NGF) is the ligand for two unrelated cellular receptors, TrkA and p75(NTR), and acts as a mediator in the development and maintenance of the mammalian nervous system. Signaling through TrkA kinase domains promotes neuronal survival, whereas activation of the p75(NTR) "death domains" induces apoptosis under correct physiological conditions. However, co-expression of these receptors leads to enhanced neuronal survival upon NGF stimulation, possibly through a ternary p75(NTR) x NGF x TrkA complex. We have expressed human p75(NTR) ligand binding domain as a secreted glycosylated protein in Trichoplusia ni cells. Following assembly and purification of soluble p75(NTR) x NGF complexes, mass spectrometry, analytical ultracentrifugation, and solution x-ray scattering measurements are indicative of 2:2 stoichiometry, which implies a symmetric complex. Molecular models of the 2:2 p75(NTR) x NGF complex based on these data are not consistent with the further assembly of either symmetric (2:2:2) or asymmetric (2:2:1) ternary p75(NTR) x NGF x TrkA complexes.

Chromatography, Gel↗

The influence and utility of varying field strength for the separation of tryptic peptides by ion mobility-mass spectrometry.

The influence of field strength on the separation of tryptic peptides by drift tube-based ion mobility-mass spectrometry is reported. Operating the ion mobility drift tube at elevated field strengths (expressed in V cm(-1) torr(-1)) reduces separation times and increases ion transmission efficiencies. Several accounts in the literature suggest that performing ion mobility separation at elevated field strength can change the selectivity of ion separation. To evaluate the field strength dependant selectivity of ion mobility separation, we examined a data set of 65 singly charged tryptic peptide ion signals (mass range 500-2500 m/z) at six different field strengths and four different drift gas compositions (He, N2, Ar, and CH4). Our results clearly illustrate that changing the field strength from low field (15 V cm(-1) torr(-1)) to high field (66 V cm(-1) torr(-1)) does not significantly alter the selectivity or peak capacity of IM-MS. The implications of these results are discussed in the context of separation methodologies that rely on the field strength dependence of ion mobility for separation selectivity, e.g., high-field asymmetric ion mobility spectrometry (FAIMS).

Amino Acid Sequence↗

The structure of gas-phase bradykinin fragment 1-5 (RPPGF) ions: an ion mobility spectrometry and H/D exchange ion-molecule reaction chemistry study.

Ion mobility-mass spectrometry (IM-MS) data is interpreted as evidence that gas-phase bradykinin fragment 1-5 (BK1-5, RPPGF) [M + H](+) ions exist as three distinct structural forms, and the relative abundances of the structural forms depend on the solvent used to prepare the matrix-assisted laser desorption ionization (MALDI) samples. Samples prepared from organic rich solvents (90% methanol/10% water) yield ions having an ion mobility arrival-time distribution (ATD) that is dominated by a single peak; conversely, samples prepared using mostly aqueous solvents (10% methanol/90% water) yield an ATD composed of three distinct peaks. The BK1-5 [M + H](+) ions were also studied by gas-phase hydrogen/deuterium (H/D) exchange ion-molecule reactions and this data supports our interpretation of the IM-MS data. Plausible structures for BK1-5 ions were generated by molecular dynamics (MD). Candidate MD-generated structures correlated to measured cross-sections suggest a compact conformer containing a beta-turn whereas a more extended, open form does not contain such an interaction. This study illustrates the importance of intra-molecular interactions in the stabilization of the gas-phase ions, and these results clearly illustrate that solution-phase parameters (i.e., MALDI sample preparation) greatly influence the structures of gas-phase ions.

Bradykinin↗

Analysis of phosphorylated peptides by ion mobility-mass spectrometry.

An ion mobility-mass spectrometry technique for rapid screening of phosphopeptides in protein digests is described. A data set of 43 sequences (ranging in mass from 400 to 3000 m/z) of model and tryptic peptides, including serine, threonine, and tyrosine phosphorylation, was investigated, and the data support our previously reported observation (Ruotolo, B. T.; Verbeck, G. F., IV; Thomson, L. M.; Woods, A. S.; Gillig, K. J.; Russell, D. H. J. Proteome Res. 2002, 1, 303.) that the drift time-m/z relationship for singly charged phosphorylated peptide ions is different from that for nonphosphorylated peptides. The data further illustrate that a combined data-dependent IM-MS/MS approach for phosphopeptide screening would have enhanced throughput over conventional MS/MS-based methodologies.

Amino Acid Sequence↗

Peak capacity of ion mobility mass spectrometry: the utility of varying drift gas polarizability for the separation of tryptic peptides.

Ion mobility mass spectrometry (IM-MS) peptide mass mapping experiments were performed using a variety of drift gases (He, N2, Ar and CH4). The drift gases studied cover a range of polarizabilities ((0.2-2.6) x 10(-24) cm3) and the peak capacities obtained for tryptic peptides in each gas are compared. Although the different gases exhibit similar peak capacities (5430 (Ar) to 7580 (N2)) in some cases separation selectivity presumably based on peptide conformers (or conformer populations), is observed. For example the drift time profiles observed for some tryptic peptide ions from aldolase (rabbit muscle) show a dependence on drift gas. The transmission of high-mass ions (m/z > 2000) is also influenced by increased scattering cross-section of the more massive drift gases. Consequently the practical peak capacity for IM-MS separation cannot be assumed to be solely a function of resolution and the ability of a gas to distribute signals in two-dimensional space; rather, peak capacity estimates must account for the transmission losses experienced for peptide ions as the drift gas mass increases.

Animals↗

Ion mobility-mass spectrometry applied to cyclic peptide analysis: conformational preferences of gramicidin S and linear analogs in the gas phase.

In this paper, we present an investigation of the gas-phase structural differences between cyclic and linear peptide ions by matrix-assisted laser desorption ionization-ion mobility-mass spectrometry. Specifically, data is shown for gramicidin S (cyclo-VOLFPVOLFP where phenylalanines are D rather than L-type amino acids and the O designates the non-standard amino acid ornithine) and five linear gramicidin S analogues. Results are interpreted as evidence for a beta-sheet (or beta-hairpin) conformational preference in both linear-protonated and sodiated-cyclic gramicidin S gas-phase peptides, and a preference for the protonated-cyclic peptide to adopt a collapsed, random coil-type conformation. A comparison with solution-phase circular dichroism measurements is performed, and structures similar to those observed in the gas phase appear to be favored in low-dielectric solvents such as 2,2,2-triflouroethanol. The utility of ion mobility-mass spectrometry (IM-MS) as a means of rapidly distinguishing between linear and cyclic peptide forms in also discussed.

Amino Acid Sequence↗

Resolution equations for high-field ion mobility.

An extension of current mobility resolution equations as they apply to high-field ion mobility spectrometry is presented. The new resolution expression is applied to arrival time distributions for ions having a large range of ion mobilities and mass-to-charge ratios (m/z). The results indicate that the new equation can be utilized to predict the mobility resolution over a broader range of applied electric fields than previous ion mobility resolution expressions.

Journal Article↗

Peak capacity of ion mobility mass spectrometry: separation of peptides in helium buffer gas.

Advances in the field of proteomics depend upon the development of high-throughput separation methods. Ion mobility-mass spectrometry is a fast separation method (separations on the millisecond time-scale), which has potential for peptide complex mixture analysis. Possible disadvantages of this technique center around the lack of orthogonality between separation based on ion mobility and separation based on mass. In order to examine the utility of ion mobility-mass spectrometry, the peak capacity (phi) of the technique was estimated by subjecting a large dataset of peptides to linear regression analysis to determine an average trend for tryptic peptides. This trend-line, along with the deviation from a linear relationship observed for this dataset, was used to define the separation space for ion mobility-mass spectrometry. Using the maximum deviation found in the dataset (+/-11%) the peak capacity of ion mobility-mass spectrometry is approximately 2600 peptides. These results are discussed in light of other factors that may increase the peak capacity of ion mobility-mass spectrometry (i.e. multiple trends in the data resulting from multiple classes of compounds present in a sample) and current liquid chromatography approaches to complex peptide mixture analysis.

Helium↗

Oligonucleotide analysis with MALDI-ion-mobility-TOFMS.

Matrix-assisted laser-desorption ionization followed by ion-mobility separation and time-of-flight mass analysis (MALDI-IM-TOFMS) has been used to characterize native and chemically modified DNA oligonucleotides up to eight bases in length. Mobility resolution between 20 and 30 can be used to separate oligonucleotides of different length, but not to differentiate between isomers or even different compositions of the same length. MALDI-IM-TOFMS does, however, have additional utility in the analysis of mixtures of DNA oligonucleotides and peptides, because these classes of molecules can be distinguished on the basis of differences in their mobility. Oligonucleotide sequencing is also possible by MALDI-IM-TOFMS. Ion signals corresponding to nucleobase losses, w-type, and y-type fragments were identified by use of differences in ion mobility. MALDI-IM-TOFMS was also used to resolve DNA-platinum adducts from the corresponding unmodified oligonucleotides.

Ions↗

Observation of conserved solution-phase secondary structure in gas-phase tryptic peptides.

Results from ion mobility studies of tryptic peptides suggest that, in some cases, the gas-phase structures can be related to the solution-phase structure of the parent protein. The interpretation of ion mobility measurements is supported by results from molecular modeling and H/D exchange experiments on the same peptides. This study clearly illustrates the utility of IM-MS for screening complex mixtures for peptides having intrinsically stable secondary/tertiary structures, and/or posttranslational modification.

Amino Acid Sequence↗

A study of peptide-peptide interactions using MALDI ion mobility o-TOF and ESI mass spectrometry.

Matrix-assisted laser desorption ionization ion mobility coupled to orthogonal time-of-flight mass spectrometry (MALDI-IM-oTOF MS) is evaluated as a tool for studying non-covalent complex (NCX) formation between peptides. The NCX formed between dynorphin 1-7 and Mini Gastrin I is used as a model system for comparison to previous MALDI experiments (Woods, A. S.; Huestis, M. A. J. Am. Soc. Mass Spectrom. 2001, 12, 88-96). The dynorphin 1-7/Mini Gastrin I complex is stable after more than a ms drift time through the He filled mobility cell. Furthermore, the effects of solution pH on NCX ion signal intensity is measured both by MALDI-IM-MS analysis and by nanoelectrospray mass spectrometry. When compared to the previous MALDI study this work shows that all three techniques give similar results. In addition, fragmentation can be observed from of the non-covalent complex parent ion that occurs prior to TOF mass analysis but after mobility separation, thus providing NCX composition information.

Cyclic GMP-Dependent Protein Kinases↗

Distinguishing between phosphorylated and nonphosphorylated peptides with ion mobility-mass spectrometry.

Mass spectrometry has become an indispensable tool in identifying post-translationally modified proteins, but multiple peptide mass-mapping/peptide-sequencing experiments are required to answer questions involving the site and type of modification present. Here, we apply ion mobility-mass spectrometry (IM-MS), a high-throughput analysis method having high selectivity and sensitivity, to the challenge of identifying phosphorylated peptides. Ion mobility separation is based on the collision cross-section of the ion. Phosphorylation can result in a conformational change in gas-phase peptide ions, which can be detected by IM. To demonstrate this point, a peptide mixture containing a variety of peptide sequences is examined with IM-MS and molecular dynamics calculations. During the course of these studies, two classes of phosphopeptide were identified: (i) phosphorylated peptide ions that have conformers that differ from the nonphosphorylated ion and (ii) phosphorylated peptide ions that have conformations that are very similar to the nonphosphorylated peptide. The utility of IM-MS peptide mass mapping for identifying both types of phosphorylated peptides is discussed.

Amino Acid Sequence↗