PubMed Health⌕ Search

Biomedical subjects

Branimir Vasilic

Publications and source records attributed to Branimir Vasilic.

3 recordsLinked to original sources

Effect of testosterone replacement on trabecular architecture in hypogonadal men.

UNLABELLED: We evaluated the effect of testosterone treatment on trabecular architecture by microMRI in 10 untreated severely hypogonadal men. After 2 years, microMRI parameters of trabecular connectivity improved significantly, suggesting the possibility that testosterone improves trabecular architecture. INTRODUCTION: Osteoporosis, characterized by low BMD and diminished bone quality, is a significant public health problem in men. Hypogonadal men have decreased BMD and deteriorated trabecular architecture compared with eugonadal men, and testosterone treatment improves their BMD. We tested the hypothesis that testosterone replacement in hypogonadal men would also improve their trabecular architecture. MATERIALS AND METHODS: We selected 10 untreated severely hypogonadal men and treated them with a testosterone gel for 24 months to maintain their serum testosterone concentrations within the normal range. Each subject was assessed before and after 6, 12, and 24 months of testosterone treatment by magnetic resonance microimaging (microMRI) of the distal tibia and by DXA of the spine and hip. The microMRI parameters reflect the integrity of the trabecular network and include the ratio of all surface voxels (representing plates) to curve voxels (representing rods) and the topological erosion index, a ratio of topological parameters expected to increase on trabecular deterioration to those expected to decrease. The higher the surface-to-curve ratio and the lower the topological erosion index, the more intact the trabecular network. RESULTS: Serum testosterone concentrations increased to midnormal after 3 months of treatment and remained normal thereafter. After 24 months of testosterone treatment, BMD of the spine increased 7.4% (p<0.001), and of the total hip increased 3.8% (p=0.008). Architectural parameters assessed by microMRI also changed: the surface-to-curve ratio increased 11% (p=0.004) and the topological erosion index decreased 7.5% (p=0.004). CONCLUSIONS: These results suggest the possibility that testosterone replacement of hypogonadal men improves trabecular architecture.

Adolescent↗

A novel local thresholding algorithm for trabecular bone volume fraction mapping in the limited spatial resolution regime of in vivo MRI.

Recent advances in micro-magnetic resonance imaging have shown the possibility of in vivo assessment of trabecular bone architecture. However, the small feature size and relatively low signal-to-noise ratio (SNR) achievable in vivo cause the intensity histogram to be unimodal. The critical first step in the processing of these images is the extraction of bone volume fraction for each voxel. Here, we propose a local threshold algorithm (LTA) that determines the marrow intensity value in the neighborhood of each voxel based on nearest-neighbor statistics. Using the local marrow intensities we threshold the image and scale the intensities of voxels partially occupied by bone to produce a marrow volume fraction map of the trabecular bone region. We show that structural parameters derived with the LTA are highly correlated with those obtained with the previously published histogram deconvolution algorithm (HDA) and that the LTA is robust to image noise corruption. The LTA is found to correctly identify trabeculae with a significantly higher reliability than HDA. Finally, we demonstrate that the LTA is superior in preserving connectivity by showing for 75 in vivo images that the genus of the trabecular bone surface is always higher than when processed with the HDA.

Algorithms↗

Coherence-induced artifacts in large-flip-angle steady-state spin-echo imaging.

High-resolution imaging of trabecular bone aimed at analyzing the bone's microarchitecture is preferably performed with spin-echo-type pulse sequences. Unlike gradient echoes, spin-echoes are immune to artifactual broadening of trabeculae caused by local static field gradients near the bone-bone marrow interface and signal loss from chemical shift dephasing at k-space center. However, the previously practiced 3D fast large-angle spin-echo (FLASE) pulse sequence was found to be prone to a low-frequency modulation artifact in both the readout and slice direction. The artifact is caused by deviations in the effective flip angle of the nonselective 180 degrees pulse, which converts a fraction of the phase-encoded transverse magnetization to longitudinal magnetization. The latter recurs as transverse magnetization in the subsequent pulse sequence cycle forming a spurious stimulated echo. The objective of this work was to perform a k-space analysis of this steady-state artifact and propose two modifications of the original 3D FLASE that effectively remove it. The results of the simulations were in exact agreement with the experiments and the proposed remedy was found to eliminate the artifact.