Thermoresponsive N,N-dialkylacrylamide copolymer blends as DNA sieving matrices with a thermally tunable mesh size.

In an earlier study we showed that a blend of thermoresponsive and nonthermoresponsive hydroxyalkylcelluloses could be used to create a thermally tunable polymer network for double-stranded (ds) DNA separation. Here, we show the generality of this approach using a family of polymers suited to a wider range of DNA separations: a blended mixture of N,N-dialkylacrylamide copolymers with different thermoresponsive behaviors. A mixture of 47% w/w N,N-diethylacrylamide (DEA)/53% w/w N,N-dimethylacrylamide (DMA) (DEA47; thermoresponsive, transition temperature = 55 degrees C in water) and 30% w/w DEA/70% w/w DMA (DEA30; nonthermoresponsive, transition temperature > 85 degrees C in water) copolymers in the ratio of 1:5 w/w DEA47:DEA30 was used to separate a dsDNA restriction digest (PhiX174-HaeIII). We investigated the effects of changing mesh size on dsDNA separation, as controlled by temperature. We observed good DNA separation performance with the copolymer blend at temperatures ranging from 25 degrees C to 48 degrees C. The separation selectivity was evaluated quantitatively for certain DNA fragment pairs as a function of temperature. The results were compared with those obtained with a control matrix consisting only of the nonthermoresponsive DEA30. Different DNA fragment pairs of various sizes show distinct temperature-dependent selectivities. Over the same temperature range, no significant temperature dependence of selectivity is observed for these DNA fragment pairs in the nonthermoresponsive control matrix. Overall, the results show similar trends in the temperature dependency of separation selectivity to what was previously observed in hydroxyalkylcellulose blends, for the same DNA fragment pairs. Finally, we showed that a ramped temperature scheme enables improved separation in the blended copolymer matrix for both small and large DNA fragments, simultaneously in a single capillary electrophoresis (CE) run.

Acrylamide↗

High-throughput, high-sensitivity genetic mutation detection by tandem single-strand conformation polymorphism/heteroduplex analysis capillary array electrophoresis.

We present the first optimization of linear polyacrylamide (LPA)-based DNA separation matrixes for an automated tandem microchannel single-strand conformation polymorphism (SSCP)/heteroduplex analysis (HA) method, implemented in capillary arrays dynamically coated with poly(N-hydroxyethylacrylamide) (polyDuramide). An optimized protocol for sample preparation allowed both SSCP and HA species to be produced in one step in a single tube and distinguished in a single electrophoretic analysis. A simple, two-color fluorescent sample labeling and detection strategy enabled unambiguous identification of all DNA species in the electropherogram, both single- and double-stranded. Using these protocols and a panel of 11 p53 mutant DNA samples in comparison with wild-type, we employed high-throughput capillary array electrophoresis (CAE) to carry out a systematic and simultaneous optimization of LPA weight-average molar mass (Mw) and concentration for SSCP/HA peak separation. The combination of the optimized LPA matrix (6% LPA, Mw 600 kDa) and a hydrophilic, adsorbed polyDuramide wall coating was found to be essential for resolution of CAE-SSCP/HA peaks and yielded sensitive mutation detection in all 11 p53 samples initially studied. A larger set of 32 mutant DNA specimens was then analyzed using these optimized tandem CAE-SSCP/HA protocols and materials and yielded 100% sensitivity of mutation detection, whereas each individual method yielded lower sensitivity on its own (93% for SSCP and 75% for HA). This simple, highly sensitive tandem SSCP/HA mutation detection method should be easily translatable to electrophoretic analyses on microfluidic devices, due to the ease of the capillary coating protocol and the low viscosity of the matrix.

Electrophoresis, Capillary↗

Microchannel DNA sequencing matrices with switchable viscosities.

We review the variety of thermo-responsive and shear-responsive polymer solutions with "switchable" viscosities that have been proposed for application as DNA sequencing matrices for capillary and microfluidic chip electrophoresis. Generally, highly entangled polymer solutions of high-molar mass polymers are necessary for the attainment of long DNA sequencing read lengths (> 500 bases) with short analysis times (< 3 h). However, these entangled polymer matrices create practical difficulties for microchannel electrophoresis with their extremely high viscosities, necessitating high-pressure loading into capillaries or chips. Shear-responsive (shear-thinning) polymer matrices exhibit a rapid drop in viscosity as the applied shear force is increased, but still require a high initial pressure to initiate flow of the solution into a microchannel. Polymer matrices designed to have thermo-responsive properties display either a lowered (thermo-thinning) or raised (thermo-thickening) viscosity as the temperature of the solution is elevated. These properties are generally designed into the polymers by the incorporation of moderately hydrophobic groups in some part of the polymer structure, which either phase-separate or hydrophobically aggregate at higher temperatures. In their low-viscosity states, these matrices that allow rapid loading of capillary or chip microchannels under low applied pressure. The primary goal of work in this area is to design polymer matrices that exhibit this responsive behavior and hence easy microchannel loading, without a reduction in DNA separation performance compared to conventional matrices. While good progress has been made, thermo-responsive matrices have yet to offer sequencing performance as good as nonthermo-responsive networks. The challenge remains to accomplish this goal through the innovative design of novel polymer structures.

Electrophoresis, Capillary↗

DNA sequencing with hydrophilic and hydrophobic polymers at elevated column temperatures.

Read length in DNA sequencing by capillary electrophoresis at elevated temperatures is shown to be greatly affected by the extent of hydrophobicity of the polymer separation matrix. At column temperatures of up to 80 degrees C, hydrophilic linear polyacrylamide (LPA) provides superior read length and separation speed compared to poly(N,N-dimethylacrylamide) (PDMA) and a 70:30 copolymer of N,N-dimethylacrylamide and N,N-diethylacrylamide (PDEA30). DNA-polymer and polymer intramolecular interactions are presumed to be a major cause of band broadening and the subsequent loss of separation efficiency with the more hydrophobic polymers at higher column temperatures. With LPA, these interactions were reduced, and a read length of 1000 bases at an optimum temperature of 70 degrees -75 degrees C was achieved in less than 59 min. By comparison, PDMA produced a read length of roughly 800 bases at 50 degrees C, which was close to the read length attained in LPA at the same temperature; however, the migration time was approximately 20% longer, mainly because of the higher polymer concentration required. At 60 degrees C, the maximum read length was 850 bases for PDMA, while at higher temperatures, read lengths for this polymer were substantially lower. With the copolymer DEA30, read length was 650 bases at the optimum temperature of 50 degrees C. Molecular masses of these polymers were determined by tandem gel permeation chromatography-multiangle laser light scattering method (GPC-MALLS). The results indicate that for long read, rapid DNA sequencing and analysis, hydrophilic polymers such as LPA provide the best overall performance.

Acrylamides↗

Poly-N-hydroxyethylacrylamide (polyDuramide): a novel, hydrophilic, self-coating polymer matrix for DNA sequencing by capillary electrophoresis.

A replaceable polymer matrix, based on the novel monomer N-hydroxyethylacrylamide (HEA), has been synthesized for application in DNA separation by microchannel electrophoresis. The monomer was found by micellar electrokinetic chromatography analysis of monomer partitioning between water and 1-octanol to be more hydrophilic than acrylamide and N,N-dimethylacrylamide. Polymers were synthesized by free radical polymerization in aqueous solution. The weight-average molar mass of purified polymer was characterized by tandem gel permeation chromatography-multiangle laser light scattering. The steady-shear rheological behavior of the novel DNA sequencing matrix was also characterized, and it was found that the viscosity of the novel matrix decreases by more than 2 orders of magnitude as the shear rate is increased from 0.1 to 1000 s(-1). Moreover, in the shear-thinning region, the rate of change of matrix viscosity with shear rate increases with increasing polymer concentration. Poly-N-hydroxyethylacrylamide (PHEA) exhibits good capillary-coating ability, via adsorption from aqueous solution, efficiently suppressing electroosmotic flow (EOF) in a manner comparable to that of poly-N,N-dimethylacrylamide. Under DNA sequencing conditions, adsorptive PHEA coatings proved to be stable and to maintain negligible EOF for over 600 h of electrophoresis. Resolution of DNA sequencing fragments, particularly fragments > 500 bases, in PHEA matrices generally improves with increasing polymer concentration and decreasing electric field strength. When PHEA is used both as a separation matrix and as a dynamic coating in bare silica capillaries, the matrix can resolve over 620 bases of contiguous DNA sequence within 3 h. These results demonstrate the good potential of PHEA matrices for high-throughput DNA analysis by microchannel electrophoresis.

Acrylamides↗

Comb-like copolymers as self-coating, low-viscosity and high-resolution matrices for DNA sequencing.

Comb-like copolymers with a polyacrylamide backbone and poly(N,N-dimethylacrylamide) grafts were prepared, as a way to combine the superior sieving properties of polyacrylamide with the self-coating properties of polydimethylacrylamide. These matrices function well in the absence of a capillary coating, and achieve separation performances for single-stranded DNA that are comparable to those of state-of-the-art long-chain linear polyacrylamide. Structural parameters such as the grafting density and the polymer molecular mass were varied, and good performance appears to be achieved with a relatively large range of parameters. Surprisingly, excellent separation is achieved even with matrices that have a viscosity as low as 200 mPa/s. A discussion of the physics underlying this behavior is provided.

Acrylamides↗

Critical factors for high-performance physically adsorbed (dynamic) polymeric wall coatings for capillary electrophoresis of DNA.

Physically adsorbed (dynamic) polymeric wall coatings for microchannel electrophoresis have distinct advantages over covalently linked coatings. In order to determine the critical factors that control the formation of dynamic wall coatings, we have created a set of model polymers and copolymers based on N,N-dimethylacrylamide (DMA) and N,N-diethylacrylamide (DEA), and studied their adsorption behavior from aqueous solution as well as their performance for microchannel electrophoresis of DNA. This study is revealing in terms of the polymer properties that help create an "ideal" wall coating. Our measurements indicate that the chemical nature of the coating polymer strongly impacts its electroosmotic flow (EOF) suppression capabilities. Additionally, we find that a critical polymer chain length is required for polymers of this type to perform effectively as microchannel wall coatings. The effective mobilities of double-stranded (dsDNA) fragments within dynamically coated capillaries were determined in order to correlate polymer hydrophobicity with separation performance. Even for dsDNA, which is not expected to be a strongly adsorbing analyte, wall coating hydrophobicity has a deleterious influence on separation performance.

Acrylamides↗