Capillary ion chromatography of inorganic anions on octadecyl silica monolith modified with an amphoteric surfactant.

A reversed-phase monolithic silica based capillary column (Onyx C(18), 150 mm x 0.1 mm) was modified with the amphoteric surfactant, N-dodecyl-N,N-(dimethylammonio)undecanoate (DDMAU) and evaluated for the separation and determination of inorganic anions using on-column capacitively coupled contactless conductivity detection (C(4)D). The chromatographic performance of the column was evaluated and under optimal conditions separation efficiencies of 56,200 plates per meter or 7025 plates per column (at detection point) were observed (for iodide). Direct plumbing of the capillary column to the micro-injector and on-column detection eliminated extra-column band broadening, thus allowing accurate analysis of van Deemter curves obtained for the monolithic capillary column. The calculated value for the C-term in the obtained van Deemter curve was between 3 and 4 ms for inorganic anions, allowing for the utilisation of relatively high flow rates without significant losses in efficiency. The performance of the C(4)D detector was investigated and compared for detection on an open tubular capillary column and on the modified monolithic silica capillary column. The on-column detection approach did not result in any significant decrease in peak sensitivity for the monolith compared to responses recorded for open tubular capillary columns, and in addition meant the system could be applied to rapid separations by simple variation in apparent column length. The proposed chromatographic system allowed for detection of common anions at sub-ppm level with a 10 nL injection volume. Additionally, on-column detection allowed visualisation of the development of the separation at any point in time and evaluation of the longitudinal uniformity of the ion-exchange coating.

Anions↗

Improved method for the determination of zinc pyrithione in environmental water samples incorporating on-line extraction and preconcentration coupled with liquid chromatography atmospheric pressure chemical ionisation mass spectrometry.

A method has been developed for the determination of zinc pyrithione (ZnPT) in environmental water samples using monolithic reversed-phase silica columns for rapid on-line large volume solid phase extraction in tandem with on-line matrix removal using sacrificial strong anion exchange (SAX) columns. This is coupled with reversed-phase liquid chromatography with atmospheric pressure chemical ionisation mass spectrometric detection. Limits of detection in spiked river water samples, using a 200 mL preconcentration volume, were determined as 18 ng L(-1), with a limit of quantitation of 62 ng L(-1). The percentage recovery from spiked river water was found to be 72+/-9 (n=3 extractions), whilst overall method precision, following 10 repeat complete analyses was found to be 27% RSD at 1 microg L(-1). Linearity was determined over the concentration range of 0.25-10 microg L(-1) and the calculated regression coefficient was R(2)=0.9802. The method was used to investigate the environmental fate of zinc pyrithione in waters and its partition coefficient between sediment and water phases.

Atmospheric Pressure↗

Novel integrated paired emitter-detector diode (PEDD) as a miniaturized photometric detector in HPLC.

A novel low power, low cost, highly sensitive, miniaturized light emitting diode (LED) based flow detector has been used as optical detector for the detection of sample components in high performance liquid chromatography (HPLC). This colorimetric detector employs two LEDs, one operating in normal mode as a light source and the other is reverse biased to work as a light detector. Instead of measuring the photocurrent directly, a simple timer circuit is used to measure the time taken for the photocurrent generated by the emitter LED (lambda(max) 500 nm) to discharge the detector LED (lambda(max) 621 nm) from 5 V (logic 1) to 1.7 V (logic 0) to give digital output directly without using an A/D converter. Employing a post-column reagent method, a Nucleosil 100-7 column (functionalized with iminodiacetic acid (IDA) groups) was used to separate a mixture of transition metal complexes, manganese(II) and cobalt(II) in 4-(2-pyridylazo)-resorcinol (PAR). All optical measurements were taken by using both the in-built HPLC variable wavelength detector and the proposed paired-emitter-detector-diode (PEDD) optical detector configured in-line for data comparison. The concentration range investigated using the PEDD was found to give a linear response to the Mn(II) and Co(II) PAR complexes. The effects of flow rate and emitter LED light source intensity were investigated. Under optimised conditions the PEDD detector offered a linear range of 0.9-100 microM and LOD of 0.09 microM for Mn-PAR complex. A linear range of 0.2-100 microM and LOD of 0.09 microM for Co-PAR complex was achieved.

Journal Article↗

Double gradient ion chromatography using short monolithic columns modified with a long chained zwitterionic carboxybetaine surfactant.

The rapid separation of inorganic anions on short monolithic columns permanently coated with a long chained zwitterionic carboxybetaine-type surfactant is shown. The surfactant, N-dodecyl-N,N-(dimethylammonio)undecanoate (DDMAU), was used to coat 2.5, 5.0 and 10 cm long reversed-phase silica monoliths, resulting in a permanent zwitterionic exchange surface when used with aqueous based eluents. The unique structure of the surfactant results in a charge double layer structure on the surface of the stationary phase, with strong internal anionic and weak external cationic exchange groups. The dissociation of the weak external carboxylic acid group acts to shield the inner anionic exchange site, resulting in substantial effective capacity changes with eluent pH. Utilising this effect with the application of an eluent pH gradient, simultaneously combined with eluent flow-rate gradients, very rapid simultaneous separations of both weakly retained anions and strongly retained polarisable anions was possible, with up to 10-fold decreases in overall run times. Coating stability and retention times under isocratic and isofluentic eluent conditions were shown to be reproducible over >450 repeat injections, with peak efficiency values averaging 29,000 N/m for the 2.5 cm column and 42,000 N/m for the 10 cm monolithic column, again under isocratic elution conditions.

Anions↗

Flow gradient liquid chromatography using a coated anion exchange microcolumn.

Ion chromatography on a 4.0-mm-long (3.0 mm ID) ion exchange column is presented. Using a 10 mM phosphate buffer (pH 2.22) the separation of up to six UV-absorbing anions was obtained using the microcolumn, containing 5 microm RP support (Phenomenex Gemini) coated with the zwitterionic surfactant, (N-dodecyl-N,N-dimethylammonio) undecanoate. The short analytical column facilitated the application of a flow gradient programme over the flow range 0.3-5 mL/min resulting in optimum resolution of nitrite, nitrate, benzoate, iodide, thiocyanate and trichloroacetate in less than 10 min. The effect of both eluent concentration and pH on the retention of six selected anions was investigated, showing a strong pH capacity dependence. The microcolumn was found to exhibit no selectivity towards chloride and so was well suited to the analysis of saline samples. To illustrate this, the rapid analysis of a concentrated iodized table salt sample (20 g/L) was carried out. Following standard addition, a concentration of 3.55 +/- 0.05 microg iodide/g and 1.05 +/- 0.02 microg iodate/g in the solid salt sample was determined.

Anions↗

Fast ion chromatography of inorganic anions and cations on a lysine bonded porous silica monolith.

A 0.46 cm x 10.0 cm silica monolith column was modified through the in situ covalent attachment of lysine (2,6-diaminohexanoic acid) groups. Due to the zwitterionic nature of the resultant stationary phase, the modified monolithic column contained both cation and anion exchange capacity. In the case of cation exchange, the capacity was found to be relatively low at between 5 and 6.5 micromoles Me2+ per column. However, as expected, the lysine monolith exhibited a higher anion exchange capacity at 12-13 micromoles A- per column (at pH 3.0), which was found to be dependent upon column pH, due to the dissociation of the weak acid carboxylic acid groups. High-performance separations of transition metal cations and inorganic anions were achieved using the modified monolith, with the effects of eluent concentration, pH and flow rate evaluated. Using elevated flow rates of up to 5 mL/min the separation of nitrite, bromate, bromide, nitrate, iodide and thiocyanate was possible in approximately 100 s with peak efficiencies of between 50 and 100,000 N/m and retention time %RSD of under 0.3%.

Anions↗

Use of temperature programming to improve resolution of inorganic anions, haloacetic acids and oxyhalides in drinking water by suppressed ion chromatography.

Temperature programming was used to improve selectivity in the suppressed ion chromatographic (IC) separation of inorganic anions, haloacetic acids and oxyhalides in drinking water samples when using NaOH gradient elution. The programme exploited varying responses of these anions to changes in temperature. Heats of adsorption (deltaH, kJ/mol) for 17 anionic species were calculated from van't Hoff plots. For haloacetic acids, both the degree of substitution and log P (log of n-octanol-waterpartition coefficient) values correlated well with the magnitude of the temperature effect, with monochloro- and monobromoacetic acids showing the largest effect (deltaH= -10.4 to -10.7 kJ/mol), dichloro- and dibromoacetic acids showing a reduced effect (deltaH= -6.8 to -8.4 kJ/mol) and trichloro-, bromodichloro- and chlorodibromoacetic acids showing the least effect (deltaH= -4.7 to -2.4 kJ/mol). The effect of temperature on oxyhalides ranged from deltaH= 8.4 kJ/mol for perchlorate to deltaH= -9.1 kJ/mol for iodate. The effectiveness of two commercial column ovens was investigated for the application of temperature gradients during chromatographic runs, with the best system applied to improve the resolution of closely retained species at the start, middle and end of the separation obtained using a previously optimised hydroxide gradient, in a real drinking water sample matrix. Retention time reproducibility of the final method ranged from 0.62 to 3.18% RSD (n = 30) showing temperature programming is indeed a practically important parameter to manipulate resolution.

Acetates↗

Zwitterionic ion chromatography with carboxybetaine surfactant-coated particle packed and monolithic type columns.

Both particle packed (25 cm x 0.46 cm I.D. SUPELCOSIL 5 microm C18) and monolithic type (10 cm x 0.46 cm I.D. Merck Chromolith Performance C18) reversed-phase substrates were dynamically coated with a carboxybetaine type zwitterionic surfactant ((dodecyldimethyl-amino) acetic acid) and investigated as stationary phases for use in zwitterionic ion chromatography (ZIC). Investigations into eluent concentration and pH were carried out using KCl eluents containing 0.2 mM of the carboxybetaine surfactant to stabilise the column coatings. It was found that eluent concentration decreased anion retention whilst simultaneously increasing peak efficiencies, which may be due to the dissociation of intra- and inter-molecular salts of the carboxybetaine surfactant under higher ionic strength conditions. The Effect of eluent pH was an increase in anion retention with decreased eluent pH due to the increased protonation of the weak acid terminal group of the carboxybetaine, causing both a relative increase in the positive charge of the stationary phase and less repulsion of the anions by the dissociated weak acid group. The carboxybetaine-coated monolithic phase was applied to rapid anion separations using elevated flow rates and flow rate gradients.

Betaine↗

Double gradient ion chromatography on a short carboxybetaine coated monolithic anion exchanger.

An ultra-short 1.0 x 0.46 cm carboxybetaine coated monolithic anion exchanger has been used with a new double gradient ion chromatography (DG-IC) technique. The novel monolithic column can be used with flow rate gradients giving excellent peak efficiencies, and retention times can be simultaneously reduced through combining flow gradients with an eluent pH gradient.

Journal Article↗

Novel ion chromatographic stationary phases for the analysis of complex matrices.

Ion chromatography (IC) has a proven track record in the determination of inorganic and organic anions and cations in complex matrices. Recently, application of IC to the separation and determination of bio-molecules such as amino acids, carbohydrates, nucleotides, proteins and peptides has also received much attention. The key to the determination of all of the above species in the most analytically challenging complex matrices is the ability to manipulate selectivity through control of stationary phase chemistry, mobile phase chemistry and the choice of detection method. This Tutorial Review summarises some of the most significant recent advances made in IC stationary phase technology. In particular, the review details stationary phases specifically designed for ion analysis in complex sample matrices, and considers in which direction future stationary phase development might proceed.

Animals↗

Direct detection of trace haloacetates in drinking water using microbore ion chromatography. Improved detector sensitivity using a hydroxide gradient and a monolithic ion-exchange type suppressor.

A highly sensitive gradient microbore ion chromatographic method was developed with electrolytically generated hydroxide eluents for the determination of low microg/L levels of chloroacetate, bromoacetate, trifluoroacetate, dichloroacetate, chlorodifluoroacetate, dibromoacetate, trichloroacetate, bromodichloroacetate and dibromochloroacetate disinfectant by-products formed as a result of chlorination of drinking waters. The possibility of using a packed bed Dionex Atlas suppressor with a hydroxide gradient at microbore flow rates was investigated in order to reduce baseline noise levels. The Atlas suppressor displayed a very significant reduction in noise levels compared to the standard alternative ASRS Ultra suppressor, reducing noise by a factor of 15-20 in some cases, allowing trace haloacetic acids (HAs) to be seen with the direct injection of 100 microL of treated water, with prior chloride and sulfate removal. To lower detection limits even further, a solid phase extraction was employed to preconcentrate HAs, resulting in detection limits of between 0.09 and 21.5 microg/L. The method was applied to the determination of HAs in environmental samples and standard addition curves for three drinking water samples were carried out for both direct injection and preconcentration methods. R2 values in both cases were > or =0.98. Combined content for US Environmental Protection Agency regulated HAs in the three drinking water samples from Dublin City University; New Ross, Co. Wexford and Drogheda, Co. Louth were 46.5, 58.3 and 12.6 microg/L, respectively.

Acetates↗

Using ion chromatography to monitor haloacetic acids in drinking water: a review of current technologies.

A review of the application of ion chromatography to the determination of haloacetic acids in drinking water is given. As it requires no sample derivatisation, ion chromatography in its various modes, such as ion-exchange, ion-interaction and ion-exclusion chromatography, is increasingly being investigated as a simpler alternative to gas chromatographic methods for the determination of polar disinfection by-products (DBPs) in drinking waters. Detection limits quoted for the regulated haloacetic acids (HAA5), are commonly in the mid to low microg/L range, however, in most cases analyte preconcentration is still necessary for detection at concentrations commonly found in actual drinking water samples. The coupling of ion chromatography to electrospray mass spectrometry provides a potential future direction, with improved sensitivity and selectivity compared to conductivity based detection, however associated cost and complexity for routine analysis is currently relatively high.

Acetates↗

Development of a micro-fluidic manifold for copper monitoring utilising chemiluminescence detection.

The progressive development of a micro-fluidic manifold for the chemiluminescent detection of copper in water samples, based on the measurement of light emitted from the Cu(ii) catalysed oxidation of 1,10-phenanthroline by hydrogen peroxide, is reported. Micro-fluidic manifolds were designed and manufactured from polymethylmethacrylate (PMMA) using three micro-fabrication techniques, namely hot embossing, laser ablation and direct micro-milling. The final laser ablated design incorporated a reagent mixing channel of dimensions 7.3 cm in length and 250 x 250 microm in width and depth (triangular cross section), and a detection channel of 2.1 cm in length and 250 x 250 microm in width and depth (total approx. volume of between 16 to 22 microL). Optimised reagents conditions were found to be 0.07 mM 1,10-phenanthroline, containing 0.10 M cetyltrimethylammonium bromide and 0.075 M sodium hydroxide (reagent 1 delivered at 0.025 mL min(-1)) and 5% hydrogen peroxide (reagent 2 delivered at 0.025 mL min(-1)). The sample stream was mixed with reagent 1 in the mixing channel and subsequently mixed with reagent 2 at the start of the detection channel. The laser ablated manifold was found to give a linear response (R(2) = 0.998) over the concentration ranges 0-150 microg L(-1) and be reproducible (% RSD = 3.4 for five repeat injections of a 75 microg L(-1) std). Detection limits for Cu(ii) were found to be 20 microg L(-1). Selectivity was investigated using a copper selective mini-chelating column, which showed common cations found in drinking waters did not cause interference with the detection of Cu(ii). Finally the optimised system was successfully used for trace Cu(ii) determinations in a standard reference freshwater sample (SRM 1640).

Catalysis↗

Rapid, low pressure, and simultaneous ion chromatography of common inorganic anions and cations on short permanently coated monolithic columns.

Short permanently coated reversed-phase silica based monolithic columns have been investigated for the rapid separation of inorganic anions and cations. One 2.5 x 0.46 cm column was permanently coated with didodecyldimethylammonium (DDAB), for anion analysis; and a second 5.0 x 0.46 cm column was coated with dioctylsulphosuccinnate (DOSS), for cation analysis. The use of a single combined eluent of 2.5 mM phthalate/1.5 mM ethylenediamine, at flow rates of between 4.0 and 8.0 mL/min, resulted in the rapid separation of 8 anions (in under 100 s) and 5 cations (in under 100 s) on the above columns when used individually, with detection limits for common anions ranging from approximately 0.25 to 5 mg/L, and between 2.5 and 50 mg/L for alkaline earth metals, by direct and indirect conductivity detection, respectively. However, with both columns subsequently connected in parallel, with the eluent delivered using a flow splitter from a single isocratic pump, the simultaneous analysis of anions and cations was also possible, based on a single conductivity detector. The potential of this system for the rapid, complete screening of water samples for multiple common anions and cations is shown.

Anions↗

Ion exchange properties of monolithic and particle type iminodiacetic acid modified silica.

A 10 cm silica monolith has been modified with iminodiacetic acid (IDA) groups and characterised for its selectivity toward alkali, alkaline earth, and selected transition metal cations. Physical characterisation of the modified monolith found non-homogeneous modification along the length of the monolith, although sufficient capacity was achieved to facilitate significant retention of alkaline earth and transition/heavy metal ions over a range of eluent pH and ionic strength conditions. For alkaline earth and transition/heavy metal ions, selectivity of the 10 cm IDA monolith closely matched that seen with a 25 cm IDA modified silica gel particle packed column, although the separation of alkali metal ions was noticeably poorer on the monolithic column. Peak efficiencies for most metal ions were of a similar order for both column types, except for Zn(II), which showed significant peak broadening on the IDA monolithic column.

Chromatography, Ion Exchange↗