Detection and validation of the body edge in low count emission tomography images.

Segmentation of the body edge in tomographic images with low count, noisy edges is needed for both PET and SPECT respiratory motion correction and brain SPECT attenuation correction. To reduce noise we re-projected tomographic images and searched for edges in the projection count profiles or their spatial derivatives. Edge location versus projection angle was fitted with cosine basis functions after rejecting outliers and including information about edges of previous sections. We processed 10 s duration FDG PET of the thorax, HMPAO brain, DAT brain and lung perfusion SPECT. Stable edges for all four types of scan were achieved but with different profiles. Edges were validated against edges of coregistered CT or MRI. The best root mean square (rms) accuracy was 8.2 mm (PET) and 5.2 mm (brain SPECT). Inter-scan variability (standard deviation) in the estimated-to-control edge distance for 17 PET scans was 0.4 mm, for 25 ordered subset expectation maximisation (OSEM) reconstructed brain SPECT 1.0 mm and for 18 filtered back-projection (FBP) reconstructed brain SPECT 1.4 mm.

Humans↗

An international survey of hospital practice in the imaging of acute scaphoid trauma.

OBJECTIVE: Scaphoid fractures are relatively common. If not treated promptly there may be risk of long-term disability. However, unnecessary wrist immobilization is inconvenient and may hinder professional activities. Therefore, early accurate diagnosis is essential. Currently, the American College of Radiology deems MRI and radiographs as the most appropriate investigations in imaging acute scaphoid trauma. Our objective was to assess scaphoid imaging protocols. MATERIALS AND METHODS: To assess scaphoid imaging protocols, an international survey of imaging practice was performed. Two hundred hospitals worldwide were sent a survey regarding their scaphoid trauma imaging protocols. Only replies from hospitals that had full CT, MRI, and scintigraphy facilities were accepted. RESULTS: Data were obtained from 105 hospitals, of which 23 had fixed protocols. The number of scaphoid radiographic views varied from two to six. Before second-line investigations were initiated, repeat radiographs were usually performed in 76 of the 105 hospitals. In 29 hospitals, other imaging techniques were used without further radiography. The usual second-line investigation was MRI in 31/105, CT in 19/105, and scintigraphy in 14/105. Further protocols included CT or MRI in 10/105, CT or scintigraphy in 6/105, scintigraphy or MRI in 6/105, CT then MRI (if CT was negative) in 1/105, both CT and scintigraphy in 1/105, and scintigraphy then CT (if positive) in 1/105. There was equal preference among MRI, CT, and scintigraphy in 10/105 centers, and clinical examination and radiographs were used alone in 6/105. CONCLUSION: The survey reveals marked inconsistency in the imaging of acute scaphoid injury. Although other factors may have played a role, limited scientific evidence regarding the ideal imaging in acute scaphoid trauma may be the root of this inconsistency.

Acute Disease↗

Variation in scanning line source sensitivity: a significant source of error in simultaneous emission-transmission tomography.

Transmission measurement is recommended in order to accurately correct for attenuation in myocardial single-photon emission tomography (SPET) studies. It is important that transmission studies are artefact-free, otherwise the attenuation-corrected SPET studies may also be affected. An assumption in transmission studies is that the measured transmission in air used as a reference scan is valid for any camera orientation. Variation in transmission source sensitivity (both source efficiency and detector sensitivity) with rotation negates this assumption and can produce errors that result in significant reconstructed artefacts. The aim of this study was to investigate the variation in transmission source sensitivity with a view to defining action thresholds for routine quality control tests. Transmission measurements in air were recorded on two commercial scanning line source installations for the 180 degrees arc normally used in myocardial SPET. Significant variation in transmission source sensitivity was observed on one system (exceeding 30%). Comparison was also made with the reference scan recorded at a different time at a fixed angular location. Both systems demonstrated measurable variation between transmission counts and the corresponding reference scan. A simulation study was undertaken using patient data to determine the influence of transmission sensitivity variation on reconstructed myocardial counts. To maintain reconstructed counts to within 15% of that obtained with artefact-free transmission data, the variation in transmission sensitivity with rotation needed to be within 5%. These results have necessitated the addition of quality control procedures and specific maintenance procedures to attempt rectification of the problem. Variation in transmission source sensitivity with rotation is a potential source of error in attenuation-corrected SPET. Steps should be taken to stabilise transmission source mountings so as to minimise this potential source of error.

Algorithms↗

Optimisation of brain SPET and portability of normal databases.

Use of a normal database in quantitative regional analysis of brain single-photon emission tomography (SPET) facilitates the detection of functional defects in individual or group studies by accounting for inter-subject variability. Different reconstruction methods and suboptimal attenuation and scatter correction methods can introduce additional variance that will adversely affect such analysis. Similarly, processing differences across different instruments and/or institutions may invalidate the use of external normal databases. The object of this study was to minimise additional variance by comparing reconstructions of a physical phantom with its numerical template so as to optimise processing parameters. Age- and gender-matched normal scans acquired on two different systems were compared using SPM99 after processing with both standard and optimised parameters. For three SPET systems we have optimised parameters for attenuation correction, lower window scatter subtraction, reconstructed pixel size and fanbeam focal length for both filtered back-projection (FBP) and iterative (OSEM) reconstruction. Both attenuation and scatter correction improved accuracy for all systems. For single-iteration Chang attenuation correction the optimum attenuation coefficient (mu) was 0.45-0.85 of the narrow beam value (Nmu) before, and 0.75-0.85 Nmu after, scatter subtraction. For accurately modelled OSEM attenuation correction, optimum mu was 0.6-0.9 Nmu before and 0.9-1.1 Nmu after scatter subtraction. FBP appeared to change in-plane voxel dimensions by about 2% and this was confirmed by line phantom measurements. Improvement in accuracy with scatter subtraction was most marked for the highest spatial resolution system. Optimised processing reduced but did not remove highly significant regional differences between normal databases acquired on two different SPET systems.

Algorithms↗

Software for image registration: algorithms, accuracy, efficacy.

Image registration is finding increased clinical use both in aiding diagnosis and guiding therapy. There are numerous algorithms for registration, which all involve maximizing a measure of similarity between a transformed floating image and a fixed reference image. The choice of the similarity measure depends, to some extent, on the application. Methods based on the use of the joint intensity histogram have become popular because of their flexibility and robustness. A distinction is made between rigid-body and non-rigid transformations. The latter are needed for inter-subject registration or intra-subject registration in cases where the region of the body of interest is not considered rigid. Non-rigid transformation is normally achieved using a global model of the deformation but can also be defined by a set of locally rigid transformations, each constrained to a small block in the image. There is scope for further research on the incorporation of appropriate constraints, especially for the application of non-rigid transformations to nuclear medicine studies. Most of the initial practical concerns regarding image registration have been overcome and there is increasing availability of commercial software. There are several approaches to the validation of registration software, with validation of non-rigid algorithms being particularly difficult. Studies have demonstrated the accuracy on the order of half a pixel for both intra- and inter-modality registration (typically 2 to 3 mm). Although hardware-based registration has now become possible by using dual-modality instruments, software-based registration will continue to play an important role in nuclear medicine.

Algorithms↗

Practical aspects of a data-driven motion correction approach for brain SPECT.

UNLABELLED: Patient motion can cause image artifacts in single photon emission computed tomography despite restraining measures. Data-driven detection and correction of motion can be achieved by comparison of acquired data with the forward projections. This enables the brain locations to be estimated and data to be correctly incorporated in a three-dimensional (3-D) reconstruction algorithm. Digital and physical phantom experiments were performed to explore practical aspects of this approach. METHODS: Noisy simulation data modeling multiple 3-D patient head movements were constructed by projecting the digital Hoffman brain phantom at various orientations. Hoffman physical phantom data incorporating deliberate movements were also gathered. Motion correction was applied to these data using various regimes to determine the importance of attenuation and successive iterations. Studies were assessed visually for artifact reduction, and analyzed quantitatively via a mean registration error (MRE) and mean square difference measure (MSD). RESULTS: Artifacts and distortion in the motion corrupted data were reduced to a large extent by application of this algorithm. MRE values were mostly well within 1 pixel (4.4 mm) for the simulated data. Significant MSD improvements (>2) were common. Inclusion of attenuation was unnecessary to accurately estimate motion, doubling the efficiency and simplifying implementation. Moreover, most motion-related errors were removed using a single iteration. The improvement for the physical phantom data was smaller, though this may be due to object symmetry. CONCLUSION: These results provide the basis of an implementation protocol for clinical validation of the technique.

Algorithms↗

Image registration: an essential tool for nuclear medicine.

There is increasing interest in being able to automatically register medical images from either the same or different modalities. Registered images are proving useful in a range of applications, not only providing more correlative information to aid in diagnosis, but also assisting with the planning and monitoring of therapy, both surgery and radiotherapy. The practising nuclear medicine specialist is faced with a dilemma in choosing an appropriate method since the literature in the field is extensive, with conflicting evidence as to what methods are optimal. Although most barriers to implementing registration in routine practice have been removed, there remains a lack of commercial, validated software. The alternative is to install a dual-modality instrument. The objective of this review is to present a general overview of medical image registration with emphasis on the application and issues relevant to nuclear medicine.

Algorithms↗