Electric fields in tumors exposed to external voltage sources: implication for electric field-mediated drug and gene delivery.

The intratumoral field, which determines the efficiency of electric field-mediated drug and gene delivery, can differ significantly from the applied field. Therefore, we investigated the distribution of the electric field in mouse tumors and tissue phantoms exposed to a large range of electric stimuli, and quantified the resistances of tumor, skin, and electrode-tissue interface. The samples used in the study included 4T1 and B16.F10 tumors, mouse skin, and tissue phantoms constructed with 1% agarose gel with or without 4T1 cells. When pulsed electric fields were applied to samples using a pair of parallel-plate electrodes, we determined the electric field and resistances in each sample as well as the resistance at the electrode-tissue interface. The electric fields in the center region of tissue phantoms and tumor slices ex vivo were macroscopically uniform and unidirectional between two parallel-plate electrodes. The field strengths in tumor tissues were significantly lower than the applied field under both ex vivo and in vivo conditions. During in vivo stimulation, the ratio of intratumoral versus applied fields was approximately either 20% or 55%, depending on the applied field. Meanwhile, the total resistance of skin and electrode-tissue interface was decreased by approximately 70% and the electric resistance at the center of both tumor models was minimally changed when the applied field was increased from 50 to 400 V/cm. These results may be useful for improving electric field-mediated drug and gene delivery in solid tumors.

Animals↗

A single molecule detection method for understanding mechanisms of electric field-mediated interstitial transport of genes.

The interstitial space is a rate limiting physiological barrier to non-viral gene delivery. External pulsed electric fields have been proposed to increase DNA transport in the interstitium, thereby improving non-viral gene delivery. In order to characterize and improve the interstitial transport, we developed a reproducible single molecule detection method to observe the electromobility of DNA in a range of pulsed, high field strength electric fields typically used during electric field-mediated gene delivery. Using agarose gel as an interstitium phantom, we investigated the dependence of DNA electromobility on field magnitude, pulse duration, pulse interval, and pore size in the interstitial space. We observed that the characteristic electromobility behavior, exhibited under most pulsing conditions, consisted of three distinct phases: stretching, reptation, and relaxation. Electromobility depended strongly on the field magnitude, pulse duration, and pulse interval of the applied pulse sequences, as well as the pore size of the fibrous matrix through which the DNA migrated. Our data also suggest the existence of a minimum pulse amplitude required to initiate electrophoretic transport. These results are useful for understanding the mechanisms of DNA electromobility and improving interstitial transport of genes during electric field-mediated gene delivery.

DNA↗

Electric fields within cells as a function of membrane resistivity--a model study.

Externally applied electric fields play an important role in many therapeutic modalities, but the fields they produce inside cells remain largely unknown. This study makes use of a three-dimensional model to determine the electric field that exists in the intracellular domain of a 10-microm spherical cell exposed to an applied field of 100 V/cm. The transmembrane potential resulting from the applied field was also determined and its change was compared to those of the intracellular field. The intracellular field increased as the membrane resistance decreased over a wide range of values. The results showed that the intracellular electric field was about 1.1 mV/cm for Rm of 10,000 omega x cm2, increasing to about 111 mV/cm as Rm decreased to 100 omega x cm2. Over this range of Rm the transmembrane potential was nearly constant. The transmembrane potential declined only as Rm decreased below 1 omega x cm2. The simulation results suggest that intracellular electric field depends on Rm in its physiologic range, and may not be negligible in understanding some mechanisms of electric field-mediated therapies.