Anatomical phenotyping in the brain and skull of a mutant mouse by magnetic resonance imaging and computed tomography.

Since genetically modified mice have become more common in biomedical research as models of human disease, a need has also grown for efficient and quantitative methods to assess mouse phenotype. One powerful means of phenotyping is characterization of anatomy in mutant vs. normal populations. Anatomical phenotyping requires visualization of structures in situ, quantification of complex shape differences between mouse populations, and detection of subtle or diffuse abnormalities during high-throughput survey work. These aims can be achieved with imaging techniques adapted from clinical radiology, such as magnetic resonance imaging and computed tomography. These imaging technologies provide an excellent nondestructive method for visualization of anatomy in live individuals or specimens. The computer-based analysis of these images then allows thorough anatomical characterizations. We present an automated method for analyzing multiple-image data sets. This method uses image registration to identify corresponding anatomy between control and mutant groups. Within- and between-group shape differences are used to map regions of significantly differing anatomy. These regions are highlighted and represented quantitatively by displacements and volume changes. This methodology is demonstrated for a partially characterized mouse mutation generated by N-ethyl-N-nitrosourea mutagenesis that is a putative model of the human syndrome oculodentodigital dysplasia, caused by point mutations in the gene encoding connexin 43.

Animals↗

Gradient hysteresis in MRI and NMR experiments.

In this paper, we describe a gradient hysteresis effect that can modulate the current in gradient coils during MRI and NMR experiments. A simple pulse sequence is presented for the purpose of evaluating the resulting changes in the accumulated phase. Additionally, the nature of the gradient pulse shape changes is described. These experiments will be of interest to MRI and NMR scientists who are developing pulse sequences requiring precision gradient performance or who are currently seeking the source of unexplained NMR artifacts.

Animals↗

Fast spin-echo for multiple mouse magnetic resonance phenotyping.

High-resolution magnetic resonance imaging is emerging as a powerful tool for phenotyping mice in biologic studies of genetic expression, development, and disease progression. In several applications, notably random mutagenesis trials, large cohorts of mice must be examined for abnormalities that may occur in any part of the body. In the aim of establishing a protocol for imaging multiple mice simultaneously in a standardized high-throughput fashion, this study investigates variations of a three-dimensional fast spin-echo sequence that implements driven equilibrium, modified refocusing, and partial excitation pulses. Sequence variations are compared by simulated and experimental measurements in phantoms and mice. Results indicate that when using a short repetition time (TR<or=T1) a sequence employing a partial excitation tip angle provides both improved signal and good T2 contrast compared with standard fast spin-echo imaging. This sequence is used to simultaneously acquire four live mouse head images at 100 microm isotropic resolution with a scan time under 3 h at 7 T.

Animals↗

In vivo multiple-mouse MRI at 7 Tesla.

We developed a live high-field multiple-mouse magnetic resonance imaging method to increase the throughput of imaging studies involving large numbers of mice. Phantom experiments were performed in 7 shielded radiofrequency (RF) coils for concurrent imaging on a 7 Tesla MRI scanner outfitted with multiple transmit and receive channels to confirm uniform signal-to-noise ratio and minimal ghost artifacts across images from the different RF coils. Grid phantoms were used to measure image distortion in different positions in the coils. The brains of 7 live mice were imaged in 3D in the RF coil array, and a second array of 16 RF coils was used to 3D image the whole bodies of 16 fixed, contrast agent-perfused mice. The images of the 7 live mouse brains at 156 microm isotropic resolution and the 16 whole fixed mice at 100 microm isotropic resolution were of high quality and free of artifacts. We have thus shown that multiple-mouse MRI increases throughput for live and fixed mouse experiments by a factor equaling the number of RF coils in the scanner.

Animals↗

Magnetic resonance imaging for detection and analysis of mouse phenotypes.

With the enormous and growing number of experimental and genetic mouse models of human disease, there is a need for efficient means of characterizing abnormalities in mouse anatomy and physiology. Adaptation of magnetic resonance imaging (MRI) to the scale of the mouse promises to address this challenge and make major contributions to biomedical research by non-invasive assessment in the mouse. MRI is already emerging as an enabling technology providing informative and meaningful measures in a range of mouse models. In this review, recent progress in both in vivo and post mortem imaging is reported. Challenges unique to mouse MRI are also identified. In particular, the needs for high-throughput imaging and comparative anatomical analyses in large biological studies are described and current efforts at handling these issues are presented.

Animals↗

A Gja1 missense mutation in a mouse model of oculodentodigital dysplasia.

Oculodentodigital dysplasia (ODDD) is an autosomal dominant disorder characterized by pleiotropic developmental anomalies of the limbs, teeth, face and eyes that was shown recently to be caused by mutations in the gap junction protein alpha 1 gene (GJA1), encoding connexin 43 (Cx43). In the course of performing an N-ethyl-N-nitrosourea mutagenesis screen, we identified a dominant mouse mutation that exhibits many classic symptoms of ODDD, including syndactyly, enamel hypoplasia, craniofacial anomalies and cardiac dysfunction. Positional cloning revealed that these mice carry a point mutation in Gja1 leading to the substitution of a highly conserved amino acid (G60S) in Cx43. In vivo and in vitro studies revealed that the mutant Cx43 protein acts in a dominant-negative fashion to disrupt gap junction assembly and function. In addition to the classic features of ODDD, these mutant mice also showed decreased bone mass and mechanical strength, as well as altered hematopoietic stem cell and progenitor populations. Thus, these mice represent an experimental model with which to explore the clinical manifestations of ODDD and to evaluate potential intervention strategies.

Abnormalities, Multiple↗

Comprehensive transthoracic cardiac imaging in mice using ultrasound biomicroscopy with anatomical confirmation by magnetic resonance imaging.

High-frequency ultrasound biomicroscopy (UBM) has recently emerged as a high-resolution means of phenotyping genetically altered mice and has great potential to evaluate the cardiac morphology and hemodynamics of mouse mutants. However, there is no standard procedure of in vivo transthoracic cardiac imaging using UBM to comprehensively phenotype the adult mice. In this paper, the characteristic mouse thoracic anatomy is elucidated using magnetic resonance (MR) imaging on fixed mice. Besides the left parasternal and apical windows commonly used for transthoracic ultrasound cardiac imaging, a very useful right parasternal window is found. We present strategies for optimal visualization using UBM of key cardiac structures including: 1) the right atrial inflow channels such as the right superior vena cava; 2) the right ventricular inflow tract via the tricuspid orifice; 3) the right ventricular outflow tract to the main pulmonary artery; 4) the left atrial inflow channel, e.g., pulmonary vein; 5) the left ventricular inflow tract via the mitral orifice; 6) the left ventricular outflow tract to the ascending aorta; 7) the left coronary artery; and 8) the aortic arch and associated branches. Two-dimensional ultrasound images of these cardiac regions are correlated to similar sections in the three-dimensional MR data set to verify anatomical details of the in vivo UBM imaging. Dimensions of the left ventricle and ascending aorta are measured by M-mode. Flow velocities are recorded using Doppler at six representative intracardiac locations: right superior vena cava, tricuspid orifice, main pulmonary artery, pulmonary vein, mitral orifice, and ascending aorta. The methodologies and baseline measurements of inbred mice provide a useful guide for investigators applying the high-frequency ultrasound imaging to mouse cardiac phenotyping.

Animals↗

Multiple mouse biological loading and monitoring system for MRI.

The use of mice to study models of human disease has resulted in a surge of interest in developing mouse MRI. The ability to take 3D, high-resolution images of live mice allows significant insight into anatomy and function. However, with imaging times on the order of hours, high throughput of specimens has been problematic. To facilitate high throughput, concurrent imaging of multiple mice has been developed; however, this poses further complexities regarding the ease and rapidity of loading several animals. In this study, custom-built equipment was developed to streamline the preparation process and to safely maintain seven mice during a multiple-mouse imaging session. Total preparation time for seven mice was approximately 24 min. ECG and temperature were monitored throughout the scan and maintained by regulating anesthetic and heating. Proof of principle was demonstrated in a 3-h imaging session of seven mice.

Animals↗

Ultrasound-guided left-ventricular catheterization: a novel method of whole mouse perfusion for microimaging.

We describe a novel technique to perform whole-body perfusion fixation in mice with specific relevance to micro-imaging. With the guidance of high-frequency ultrasound imaging, we were able to perfuse fixative and contrast agents via a catheter inserted into the left ventricle, and therefore preserved the integrity of the chest and abdominal cavity. In this preliminary study, our success rate over 15 animals was 73%. We demonstrate applications of this technique for magnetic resonance imaging and micro-CT, but we expect that this method can be generally applied to whole-body perfusions of other small animals in which the intact body is necessary.

Animals↗