PubMed Health⌕ Search

Biomedical subjects

Brian R Stoner

Publications and source records attributed to Brian R Stoner.

2 recordsLinked to original sources

Template-directed assembly on an ordered microsphere array.

We investigated the capability of an ordered array of microspheres to act as a template for deposition and ordering of a subsequent layer of microspheres. An evaporation-based technique was used to deposit monolayers of large colloidal spheres. A novel technique for selective deposition of polyelectrolyte film was used to stabilize the arrays and optimize the bead-substrate interaction. The template behavior of face-centered cubic and body-centered cubic (bcc) microsphere arrays was studied by optical and scanning electron microscopy, and the packing geometry was found to have a dramatic effect on the arrangement of the subsequent layer. A geometrical interpretation of the experimental data explains why a bcc bead array is well suited to act as a template for an additional layer of microspheres.

Journal Article↗

Finite element analysis on dental implant-supported prostheses without passive fit.

PURPOSE: The purpose of this study is to use finite element analysis to investigate the effect of misfit prostheses, cantilever prostheses, and various occlusal forces on the stress distribution in the prostheses, implant components, and surrounding bone. MATERIALS AND METHODS: Two 3-dimensional finite element models were constructed: (1) a 2-implant-supported, 2-unit fixed partial denture and (2) a 2-implant-supported, 2-unit fixed partial denture with a distal cantilever. Variations of the standard finite element models were made by placing a 111-microm gap between the gold cylinder on either the mesial or distal implant. The effects of load of 100 N were tested on all models. Subsequently, loads of 50 N, 200 N, and 300 N were evaluated on the cantilever model. RESULTS: When the gap was positioned near to the applied force, the stress in both models increased significantly in the implant components and surrounding bone. The stress increase in each component ranged from 8% to 64% in the non-cantilever models and 43% to 85% in the cantilever models. The greatest stress was found in the distal gold screw. The effect of the gap was clearly shown by the pattern of stress distribution in both models. Additionally, the presence of a cantilever and excessive occlusal force amplified the effect of prosthesis misfit. CONCLUSIONS: Prosthesis misfit influenced the pattern and magnitude of stress distribution in the prosthesis, implant components, and surrounding bone, and the presence of the cantilever or greater occlusal force amplified the effect of misfit.

Bite Force↗