PubMed Health⌕ Search

Biomedical subjects

Brian Snyder

Publications and source records attributed to Brian Snyder.

8 recordsLinked to original sources

Porous silk fibroin 3-D scaffolds for delivery of bone morphogenetic protein-2 in vitro and in vivo.

Bone morphogenetic protein-2 (BMP-2) plays a key role in osteogenesis. Biomaterials used for the sustained delivery of BMP-2 in vivo have shown therapeutic benefits. In the present study, BMP-2 was loaded in porous silk fibroin scaffolds derived from silkworm cocoons (2.4 +/- 0.14 microg per scaffold). The release profile of BMP-2 under dynamic culture conditions (spinner flasks) showed that after 1 week in culture 25% of the initial BMP-2 was retained adsorbed to the scaffold; up to 4 weeks no additional BMP-2 was released. BMP-2 induced human bone marrow stromal cells (hMSCs) to undergo osteogenic differentiation when the seeded scaffolds were cultured in medium supplemented with osteogenic stimulants for 4 weeks, based on elevated alkaline phosphatase activity, calcium deposition, and transcript levels for bone sialoprotein, osteopontin, osteocalcin, BMP-2, and cbfa-1. Micro-computed tomography revealed densely deposited mineral at the center of the scaffolds. In contrast, hMSCs cultured in control scaffolds (no BMP-2) exhibited limited osteogenesis. When implanted in critical sized cranial defects in mice, scaffolds loaded with BMP-2 and seeded with hMSCs resulted in significant bone ingrowth. These results were qualitatively similar to scaffolds loaded with BMP-2 but no hMSCs or with BMP-2 and hMSCs but not pregrown into bone-like tissue. Bone-related outcomes were improved when compared with the scaffold controls implanted without BMP-2. These studies illustrate the potential use of slow degrading silk fibroin 3-D scaffolds loaded with BMP-2, in combination with hMSCs, in osteogenesis studies in vitro and in vivo, and provide a new range of material properties for these applications.

Adsorption↗

Silk implants for the healing of critical size bone defects.

Bone (re)-generation and bone fixation strategies utilize biomaterial implants, which are gradually replaced by autologous tissues. Ideally, these biomaterials should be biodegradable, osteoconductive, and provide mechanical strength and integrity until newly formed host tissues can maintain function. Some protein-based biomaterials such as collagens are promising because of their biological similarities to natural proteins on bone surfaces. However, their use as bone implant materials is largely hampered by poor mechanical properties. In contrast, silks offer distinguishing mechanical properties that are tailorable, along with slow degradability to permit adequate time for remodeling. To assess the suitability of silk-based biomaterials as implants for bone healing, we explored the use of novel porous silk fibroin scaffolds as templates for the engineering of bone tissues starting from human bone marrow derived stem cells cultured under osteogenic conditions for up to 5 weeks. The slowly degrading protein matrix permitted adequate temporal control of hydroxyapatite deposition and resulted in the formation of a trabecular-like bone matrix in bioreactor studies. The organic and inorganic components of the engineered bone tissues resembled those of bone, as shown by gene expression analysis, biochemical assays, and X-ray diffractometry. Implantation of the tissue-engineered bone implants (grown in bioreactors for 5 weeks prior to implantation) into calvarial critical size defects in mice demonstrated the capacity of these systems to induce advanced bone formation within 5 weeks, whereas the implantation of stem cell loaded silk scaffolds, and scaffolds alone resulted in less bone formation. These results demonstrate the feasibility of silk-based implants with engineered bone for the (re-)generation of bone tissues and expand the class of protein-based bone-implant materials with a mechanically stable and durable option.

Animals↗

Engineering bone-like tissue in vitro using human bone marrow stem cells and silk scaffolds.

Porous biodegradable silk scaffolds and human bone marrow derived mesenchymal stem cells (hMSCs) were used to engineer bone-like tissue in vitro. Two different scaffolds with the same microstructure were studied: collagen (to assess the effects of fast degradation) and silk with covalently bound RGD sequences (to assess the effects of enhanced cell attachment and slow degradation). The hMSCs were isolated, expanded in culture, characterized with respect to the expression of surface markers and ability for chondrogenic and osteogenic differentiation, seeded on scaffolds, and cultured for up to 4 weeks. Histological analysis and microcomputer tomography showed the development of up to 1.2-mm-long interconnected and organized bonelike trabeculae with cuboid cells on the silk-RGD scaffolds, features still present but to a lesser extent on silk scaffolds and absent on the collagen scaffolds. The X-ray diffraction pattern of the deposited bone corresponded to hydroxyapatite present in the native bone. Biochemical analysis showed increased mineralization on silk-RGD scaffolds compared with either silk or collagen scaffolds after 4 weeks. Expression of bone sialoprotein, osteopontin, and bone morphogenetic protein 2 was significantly higher for hMSCs cultured in osteogenic than control medium both after 2 and 4 weeks in culture. The results suggest that RGD-silk scaffolds are particularly suitable for autologous bone tissue engineering, presumably because of their stable macroporous structure, tailorable mechanical properties matching those of native bone, and slow degradation.

Absorbable Implants↗

Bone tissue engineering using human mesenchymal stem cells: effects of scaffold material and medium flow.

We report studies of bone tissue engineering using human mesenchymal stem cells (MSCs), a protein substrate (film or scaffold; fast degrading unmodified collagen, or slowly degrading cross-linked collagen and silk), and a bioreactor (static culture, spinner flask, or perfused cartridge). MSCs were isolated from human bone marrow, characterized for the expression of cell surface markers and the ability to undergo chondrogenesis and osteogenesis in vitro, and cultured for 5 weeks. MSCs were positive for CD105/endoglin, and had a potential for chondrogenic and osteogenic differentiation. In static culture, calcium deposition was similar for MSC grown on collagen scaffolds and films. Under medium flow, MSC on collagen scaffolds deposited more calcium and had a higher alcaline phosphatase (AP) activity than MSC on collagen films. The amounts of DNA were markedly higher in constructs based on slowly degrading (modified collagen and silk) scaffolds than on fast degrading (unmodified collagen) scaffolds. In spinner flasks, medium flow around constructs resulted in the formation of bone rods within the peripheral region, that were interconnected and perpendicular to the construct surface, whereas in perfused constructs, individual bone rods oriented in the direction of fluid flow formed throughout the construct volume. These results suggest that osteogenesis in cultured MSC can be modulated by scaffold properties and flow environment.

Bioreactors↗

Molecular rectification and conductance switching in carbon-based molecular junctions by structural rearrangement accompanying electron injection.

Molecular junctions were fabricated consisting of a 3.7 nm thick layer of nitroazobenzene (NAB) molecules between a pyrolyzed photoresist substrate (PPF) and a titanium top contact which was protected from oxidation by a layer of gold. Raman spectroscopy, XPS, and AFM revealed that the NAB layer was 2-3 molecules thick and was bonded to the two conducting contacts by C-C and N-Ti covalent bonds. The current/voltage behavior of the PPF/NAB(3.7)/Ti junctions showed strong and reproducible rectification, with the current at +2 V exceeding that at -2 V by a factor of 600. The observed current density at +3 V was 0.71 A/cm(2), or about 10(5) e(-)/s/molecule. The i/V response was strongly dependent on temperature and scan rate, with the rectification ratio decreasing for lower temperature and faster scans. Junction conductivity increased with time over several seconds at room temperature in response to positive voltage pulses, with the rate of increase larger for more positive potentials. Voltage pulses to positive potentials and back to zero volts revealed that electrons are injected from the Ti to the NAB, to the extent of about 0.1-1 e(-)/molecule for a +3 V pulse. These electrons cause an activated transition of the NAB into a more conductive quinoid state, which in turn causes an increase in conductivity. The transition to the quinoid state involves nuclear rearrangement which occurs on a submillisecond to several second time scale, depending on the voltage applied. The quinoid state is stable as long as the applied electric field is present, but reverts back to NAB within several minutes after the field is relaxed. The results are interpreted in terms of a thermally activated, potential dependent electron transfer into the 3.7 nm NAB layer, which brings about a conductivity increase of several orders of magnitude.

Journal Article↗

Performance of pyrolyzed photoresist carbon films in a microchip capillary electrophoresis device with sinusoidal voltammetric detection.

Pyrolyzed photoresist films (PPF) are introduced as planar carbon electrodes in a PDMS-quartz hybrid microchip device. The utility of PPF in electroanalytical applications is demonstrated by the separation and detection of various neurotransmitters. PPF is found to form a stable, low-capacitance, durable layer on quartz, which can then be used in conjunction with a microchip capillary electrophoretic device. Sinusoidal voltammetric detection at PPF electrodes is shown to be very sensitive, with a detection limit (S/N = 3) of 100 nM for dopamine, corresponding to a mass detection limit (S/N = 3) of 2 amol. The selectivity of analysis in the frequency domain is demonstrated by isolating each individual signal in a pair of analytes that are chromatographically unresolved. Effectively decoupling the electrophoresis and electrochemical systems allows the electrodes to be placed just inside the separation channel, which results in efficient separations (80 000-100 000 plates/m).

Journal Article↗

Relationships among musculoskeletal impairments and functional health status in ambulatory cerebral palsy.

Orthopedic surgery for patients with cerebral palsy addresses motion impairments, assuming that this will improve motor function. This study evaluates the relationships among clinical impairment measures with standardized assessments of function and disability as an initial step in testing this assumption. A total of 129 ambulatory children and adolescents across six institutions participated in a prospective evaluation that consisted of passive motion and spasticity examination of the lower extremities, three-dimensional gait temporal-spatial and kinematic analysis, and administration of the Gross Motor Function Measure (GMFM) and the Pediatric Outcomes Data Collection Instrument (PODCI). The analysis found that isolated impairment measures of motion and spasticity were only weakly related to motor function in cerebral palsy and even when averaged across multiple joints yielded no more than a fair correlation with functional scores, nor did a combination of impairments emerge that could predict substantial variance in motor function. These findings suggest that caution should be exercised when anticipating functional change through the treatment of isolated impairment and that addressing multiple impairments may be needed to produce appreciable effects.

Adolescent↗