PubMed Health⌕ Search

Biomedical subjects

Brian W Pogue

Publications and source records attributed to Brian W Pogue.

At least 19 recordsLinked to original sources

Absorption and scattering imaging of tissue with steady-state second-differential spectral-analysis tomography.

A novel approach to reconstructing both the absorption and the scattering properties of a turbid medium simultaneously from steady-state broadband spectral measurements is presented that utilizes second-differential fitting to the water spectrum to estimate the optical path length in tissue. Theoretical and experimental evidence is provided to demonstrate the robust accuracy of the spectroscopy approach and reconstructed absorption images. The steady-state broadband CCD system has the potential to provide accurate chromophore imaging without the technological complexity of time- or frequency-domain systems.

Absorption↗

Breast deformation modelling for image reconstruction in near infrared optical tomography.

Near infrared tomography (NIR) is a novel imaging technique that can be used to reconstruct tissue optical properties from measurements of light propagation through tissue. More specifically NIR measurements over a range of wavelengths can be used to obtain internal images of physiologic parameters and these images can be used to detect and characterize breast tumour. To obtain good NIR measurements, it is essential to have good contact between the optical fibres and the breast which in-turn results in the deformation of the breast due to the soft plasticity of the tissue. In this work, a tissue deformation model of the female breast is presented that will account for the altered shape of the breast during clinical NIR measurements. Using a deformed model of a breast, simulated NIR data were generated and used to reconstruct images of tissue absorption and reduced scatter using several assumptions about the imaging domain. Using either a circular or irregular 2D geometry for image reconstruction produces good localization of the absorbing anomaly, but it leads to degradation of the image quality. By modifying the assumptions about the imaging domain to a 3D conical model, with the correct diameter at the plane of NIR measurement, significantly improves the quality of reconstructed images and helps reduce image artefacts. Finally, assuming a non-deformed breast shape for image reconstruction is shown to lead to poor quality images since the geometry of the breast is greatly altered, whereas using the correct deformed geometry produces the best images.

Algorithms↗

Automated region detection based on the contrast-to-noise ratio in near-infrared tomography.

The contrast-to-noise ratio (CNR) was used to determine the detectability of objects within reconstructed images from diffuse near-infrared tomography. It was concluded that there was a maximal value of CNR near the location of an object within the image and that the size of the true region could be estimated from the CNR. Experimental and simulation studies led to the conclusion that objects can be automatically detected with CNR analysis and that our current system has a spatial resolution limit near 4 mm and a contrast resolution limit near 1.4. A new linear convolution method of CNR calculation was developed for automated region of interest (ROI) detection.

Artifacts↗

Electromagnetic breast imaging: average tissue property values in women with negative clinical findings.

Representative data are provided for three electromagnetic breast imaging techniques-near-infrared spectroscopy, electrical impedance spectroscopy, and microwave imaging spectroscopy-to serve as potential benchmarks for future investigation. The breasts of 23 women without clinical or mammographic findings of disease were imaged in the coronal plane with nonionizing radiation of varying frequencies. Average electromagnetic property values were reconstructed at each frequency on the basis of computational models of light diffusion, current flow, and microwave propagation. Electromagnetic properties were correlated with subject characteristics and between techniques. Each technique yielded information on breast tissue features (eg, conductivity, permittivity, light scattering, and absorption) that had not previously all been measured in the same individuals.

Adult↗

Fluorescence imaging in vivo: raster scanned point-source imaging provides more accurate quantification than broad beam geometries.

Two fluorescence imaging systems were compared for their ability to quantify mean fluorescence intensity from surface-weighted imaging of tissue. A broad beam CCD camera system was compared to a point sampling system that raster scans to create the image. The effects of absorption and scattering in the background tissue volume were shown to be similar in their effect upon the signal, but the effect of the three-dimensional shape of the tissue was shown to be a significant distortion upon the signal. Spherical phantoms with Intralipid and blood for absorber and scatterer were used with a fixed concentration of aluminum phthalocyanine fluorophore to illustrate that the mean intensity observed with the broad beam system increased with size, while the mean intensity observed with the raster scanned system was not as significantly affected. Similar results were observed in vivo with mice injected with the fluorophore and imaged multiple times to observe the pharmacokinetics of the drug. The fluorescence in the tumor observed with the broad beam system was higher than that observed with the raster scanned system. Based upon the phantom and animal observations in this study, it should be concluded that using broad beam fluorescence imaging systems to quantify fluorescence in vivo may be problematic when comparing tissues with different three dimensional characteristics. In particular, the ratio of fluorescence from tumor to normal tissue can yield inaccurate results when the tumor is large. However, similar measurements with a narrow beam system that is raster scanned to create the images are not as significantly affected by the three dimensional shape of the tissue. Raster scanned imaging appears to provide a more uniform and accurate way to quantify fluorescence signals from distributed tissues in vivo.

Animals↗

Analysis of effective molecular diffusion rates for verteporfin in subcutaneous versus orthotopic Dunning prostate tumors.

Photosensitizer biodistribution change inside tissue is one of the dominant factors in photodynamic therapy efficacy. In this study, the pharmacokinetics of a benzoporphyrin derivative (BPD), delivered in verteporfin for injection formulation, have been quantified in the rat Dunning prostate tumor MAT-LyLu model, using both subcutaneous and orthotopic sites. Blood plasma sampling indicated that BPD had a bi-exponential metabolic lifetime in vivo, with the two lifetimes being 9.6 min and 8.3 h. The spatial distributions in the tumor were quantified as a function of distance from the perfused blood vessels, using fluorescence histologic images of the tumor. A fluorescent vascular marker was used to obtain locations and shapes of perfused capillaries at a wavelength of emission different from that of BPD and to allow colocalized images to be acquired of vessel and BPD locations. Using the BPD fluorescence images obtained 15 min after intravenous administration, a forward finite-element solution to the diffusion equation was used to predict the drug distribution by matching the fluorescence intensity images observed microscopically. An inverse solver was used to minimize the root mean square error between the image of simulated diffusion and the experimental image, resulting in estimation of the diffusion coefficient of BPD in the tumor models. Effective diffusion coefficients were 0.88 and 1.59 microm2/s for the subcutaneous and orthotopically grown tumors, respectively, indicating that orthotopic tumors have significantly higher vascular extravasation rates as compared with subcutaneous tumors. This analysis supports the hypothesis that leakage rates of the photosensitizer vary considerably. Thus, although varying the time between injection and optical irradiation may be used to vary the targeting between vascular and less vascular areas, the precise time of treatment will depend on the nature of the permeability of the vasculature in the tissue being treated.

Animals↗

Assessment of photosensitizer dosimetry and tissue damage assay for photodynamic therapy in advanced-stage tumors.

Photodynamic therapy (PDT) efficacy is a complex function of tissue sensitivity, photosensitizer (PS) uptake, tissue oxygen concentration, delivered light dose and some other parameters. To better understand the mechanisms and optimization of PDT treatment, we assessed two techniques for quantifying tissue PS concentration and two methods for quantifying pathological tumor damage. The two methods used to determine tissue PS concentration kinetic were in vivo fluorescence probe and ex vivo chemical extraction. Both methods show that the highest tumor to normal tissue PS uptake ratio appears 4 h after PS administration. Two different histopathologic techniques were used to quantify tumor and normal tissue damage. A planimetry assessment of regional tumor necrosis demonstrated a linear relationship with increasing light dose. However, in large murine tumors this finding was complicated by the presence of significant spontaneous necrosis. A second method (densitometry) assessed cell death by nuclear size and density. With some exceptions the densitometry method generally supported the planimetry results. Although the densitometry method is potentially more accurate, it has greater potential subjectivity. Finally, our research suggests that the tools or methods we are studying for quantifying PS levels and tissue damage are necessary for the understanding of PDT effect and therapeutic ratio in experimental in vivo tumor research.

Animals↗

Interpreting hemoglobin and water concentration, oxygen saturation, and scattering measured in vivo by near-infrared breast tomography.

Near-infrared spectroscopic tomography was used to measure the properties of 24 mammographically normal breasts to quantify whole-breast absorption and scattering spectra and to evaluate which tissue composition characteristics can be determined from these spectra. The absorption spectrum of breast tissue allows quantification of (i) total hemoglobin concentration, (ii) hemoglobin oxygen saturation, and (iii) water concentration, whereas the scattering spectrum provides information about the size and number density of cellular components and structural matrix elements. These property data were tested for correlation to demographic information, including subject age, body mass index, breast size, and radiographic density. Total hemoglobin concentration correlated inversely to body mass index, likely because lower body mass indicates proportionately less fat and more glandular tissue, and glandular tissue contains greater vascularity, hence, more total hemoglobin. Optical scattering was correlated to breast diameter, subject age, and radiographic density. In the radiographic density, fatty breasts had low scattering power and extremely dense breasts had higher values. This observation is consistent with low attenuation of conventional x-rays with fat and higher attenuation in glandular tissues. Optically, fatty tissues have large scatterers leading to a low scattering power, whereas glandular or fibrous tissues have more cellular and collagen-based structures that lead to high scattering power. The study presents correlative data supporting the hypothesis that optical measurements of absorption and scattering can provide physiologically relevant information about breast tissue composition. These breast constituents vary significantly between individuals and can be altered because of changes in breast physiology or pathological state.

Adult↗

The effects of internal refractive index variation in near-infrared optical tomography: a finite element modelling approach.

Near-infrared (NIR) tomography is a technique used to measure light propagation through tissue and generate images of internal optical property distributions from boundary measurements. Most popular applications have concentrated on female breast imaging, neonatal and adult head imaging, as well as muscle and small animal studies. In most instances a highly scattering medium with a homogeneous refractive index is assumed throughout the imaging domain. Using these assumptions, it is possible to simplify the model to the diffusion approximation. However, biological tissue contains regions of varying optical absorption and scatter, as well as varying refractive index. In this work, we introduce an internal boundary constraint in the finite element method approach to modelling light propagation through tissue that accounts for regions of different refractive indices. We have compared the results to data from a Monte Carlo simulation and show that for a simple two-layered slab model of varying refractive index, the phase of the measured reflectance data is significantly altered by the variation in internal refractive index, whereas the amplitude data are affected only slightly.

Computer Simulation↗

In vivo near-infrared spectral detection of pressure-induced changes in breast tissue.

A diffuse near-infrared tomography system was used to measure dynamic changes in the absolute optical properties of the human breast that were induced through pressure applied to the tissue surface. Results from five subjects show that absorption and scattering coefficients changed measurably when pressure was increased and that these relative changes correlated with the subjects' body-mass index, indicating that the effect depends on tissue composition. Fitting the absolute absorption and scattering coefficients at six wavelengths to the molar absorption spectra of the three predominant chromophores revealed that both the average total hemoglobin and oxygen saturation increased by 10%, while water concentration decreased by more than 12%. These changes indicate that the pressure-induced variation is likely due to water displacement and vascular volume increase in the region being imaged, for mild application of pressure to the breast. These results suggest that the pressure applied during optical measurements of tissue may alter the tissue physiology, and care should be taken to factor this effect into the design of optical medical instrumentation. In addition, the technique provides a unique approach to measuring tissue elastic changes in vivo in the female breast and may offer a new method for dynamic contrast imaging based on elasto-optical measurements.

Adult↗

Three-dimensional optical tomography: resolution in small-object imaging.

Near-infrared (NIR) optical tomography provide estimates of the internal distribution of optical absorption and transport scattering from boundary measurement of light propagation within biological tissue. Although this is a truly three-dimensional (3D) imaging problem, most research to date has concentrated on two-dimensional modeling and image reconstruction. More recently, 3D imaging algorithms are demonstrating better estimation of the light propagation within the imaging region and are providing the basis of more accurate image construction algorithms. As 3D methods emerge, it will become increasingly important to evaluate their resolution, contrast, and localization of optical property heterogeneity. We present a concise study of 3D reconstructed resolution of a small, low-contrast, absorbing and scattering anomaly as it is placed in different locations within a cylindrical phantom. The object is an 8-mm-diameter cylinder, which represents a typical small target that needs to be resolved in NIR mammographic imaging. The best resolution and contrast is observed when the object is located near the periphery of the imaging region (12-22 mm from the edge) and is also positioned within the multiple measurement planes, with the most accurate results seen for the scatter image when the anomaly is at 17 mm from the edge. Furthermore, the accuracy of quantitative imaging is increased to almost 100% of the target values when a priori information regarding the internal structure of imaging domain is utilized.

Breast Neoplasms↗

Photodynamic therapy with verteporfin in the radiation-induced fibrosarcoma-1 tumor causes enhanced radiation sensitivity.

Photodynamic therapy (PDT) with verteporfin (lipid form of benzoporphyrin derivative,benzoporphyrin derivative monoacid ring A) was used to treat radiation-induced fibrosarcoma tumors before X-ray treatment. When verteporfin was injected 3 h before light irradiation, the tumor partial pressure of oxygen (pO(2)) rose from a pretreatment value of 2.8 +/- 1 to 15.2 +/- 6.9 mm Hg immediately after light application was complete (P = 0.048). When the optical irradiation was given 15 min after verteporfin injection, the tumor pO(2) decreased slightly after treatment [i.e., 6.8 +/- 1.6 mm Hg (pretreatment) versus 4.1 +/- 0.3 mm Hg (posttreatment)], whereas control tumor pO(2) did not change significantly. In vitro study of the cellular oxygen consumption rate before and after PDT treatment indicated that the consumption rate decreased linearly with delivered optical dose and quantitatively matched the loss of cell viability as measured by a mitochondrial tetrazolium assay. Doppler measurements show that red cell flux is still patent immediately after treatment, indicating that oxygen should still be delivered to the tumor. Computational simulations of the oxygen supply from the vessels and the consumption from mitochondrial activity confirmed that if oxygen consumption is decreased in the presence of unhindered blood flow, the tumor oxygenation should rise, and the hypoxic fraction of the tumor should decrease. Combination treatments with PDT delivered (100 J/cm(2) optical dose, with 1 mg/kg benzoporphyrin derivative monoacid ring A injected 3 h before treatment) after radiation treatment (10 Gy from 300 keV source) were compared with PDT delivered simultaneously with radiation. Tumor regrowth assay showed that the delays to reach double the tumor volume for PDT alone and radiation alone were 2.7 +/- 1.6 and 3.2 +/- 1.7 days, respectively. When radiation was given before PDT, the delay was 5.4 +/- 1.4 days, and when PDT was given at the same time as radiation, the delay was 8.1 +/- 1.5 days. This observation indicates that the combined effect in the latter case was greater than additive (P = 0.049).

Animals↗

Multiwavelength three-dimensional near-infrared tomography of the breast: initial simulation, phantom, and clinical results.

Three-dimensional (3D), multiwavelength near-infrared tomography has the potential to provide new physiological information about biological tissue function and pathological transformation. Fast and reliable measurements of multiwavelength data from multiple planes over a region of interest, together with adequate model-based nonlinear image reconstruction, form the major components of successful estimation of internal optical properties of the region. These images can then be used to examine the concentration of chromophores such as hemoglobin, deoxyhemoglobin, water, and lipids that in turn can serve to identify and characterize abnormalities located deep within the domain. We introduce and discuss a 3D modeling method and image reconstruction algorithm that is currently in place. Reconstructed images of optical properties are presented from simulated data, measured phantoms, and clinical data acquired from a breast cancer patient. It is shown that, with a relatively fast 3D inversion algorithm, useful images of optical absorption and scatter can be calculated with good separation and localization in all cases. It is also shown that, by use of the calculated optical absorption over a range of wavelengths, the oxygen saturation distribution of a tissue under investigation can be deduced from oxygenated and deoxygenated hemoglobin maps. With this method the reconstructed tumor from the breast cancer patient was found to have a higher oxy-deoxy hemoglobin concentration and also a higher oxygen saturation level than the background, indicating a ductal carcinoma that corresponds well to histology findings.

Aged↗

Hemoglobin imaging with hybrid magnetic resonance and near-infrared diffuse tomography.

This study examines the methodology of combining high-resolution information from magnetic resonance imaging into the reconstruction of near-infrared images of hemoglobin concentration and oxygen saturation. This type of hybrid imaging modality has the potential to provide noninvasive maps of hemoglobin concentration and oxygen saturation with relatively high spatial resolution with a fast time response. The study uses (i) tissue-simulating phantoms, as well as (ii) a rat cranial model, to test the method in two well-controlled situations. The phantom test demonstrates that better reconstruction accuracy can be achieved with the use of MRI-generated spatial regions in near-infrared reconstruction. The rat functional testing reveals that the technique can be applied to in vivo physiology, even in situations where the tissue is quite heterogenous. It also shows that the application of a priori structure in the finite element mesh as well as spatial constraints in the near-infrared image reconstruction, can significantly improve the quality of the resulting hemoglobin images.

Animals↗

Strategies for absolute calibration of near infrared tomographic tissue imaging.

Quantitative near infrared (NIR) imaging of tissue requires the use of a diffusion model-based reconstruction algorithm, which solves for the absorption and scattering coefficients of a tissue volume by matching transmission measurements of light to the predictive diffusion equation solution. Calibration problems as well as other practical considerations arise for an imaging system when using a model-based method for a real system. For example, systematic noise in the data acquisition hardware and source/detector fibers must be removed to prevent spurious results in the reconstructed image. Practical considerations for a NIR diffuse tomographic imaging system include: (1) calibration with a homogeneous phantom, (2) use of a homogenous fitting algorithm to arrive at an initial optical property estimate for image reconstruction of a heterogeneous medium, and (3) correction for fluctuations in source strength and initial phase offset during data acquisition. These practical considerations, which rely on an accurate homogeneous fitting algorithm are described. They have allowed demonstration of a prototype imaging system that has the ability to quantitatively reconstruct heterogeneous images of hemoglobin concentrations within a highly scattering medium with no a priori information.

Algorithms↗

Spatial heterogeneity and temporal kinetics of photosensitizer (AlPcS2) concentration in murine tumors RIF-1 and MTG-B.

In this study we compared the photosensitizer concentration in two experimental murine tumors using an in situ fluorescence detection instrument to examine temporal and spatial variations, after intravenous versus intratumor injection. Also, the variations in the estimate as detected by large area sampling and micro-region sampling are compared, in order to determine what the inter-tissue and inter-animal variations are, and how the method of sampling affects this estimate. The latter study was carried out ex vivo in the same tumors, which had been harvested and frozen after in vivo measurements were made. The photosensitizer, disulphonated aluminum phthalocyanine (AlPcS2) was injected either intravenously (IV) or directly into the tumor (ITu), using two murine models, MTG-B (mammary adenocarcinoma) and RIF-1 (radiation-induced fibrosarcoma) grown subcutaneously on the flank. An in situ microsampling fluorescence probe was used to assess photosensitizer concentration, through real-time measurement of the remitted intensity. The photosensitizer concentration was evaluated at 8 time endpoints between 15 min and 48 h post-injection. Inter-tumor and intra-tumor variations were assessed by repeated samples from the tumor tissues. The average photosensitizer level reaches a peak between 3 to 6 h in both tumor and normal tissues using IV administration, but peaks within 1 h following ITu administration. MTG-B tumors demonstrated a factor of 2 higher uptake than RIF-1 tumors. The pharmacokinetic uptake rates of the RIF-1 tumor were 3 times faster than for MTG-B, while there was no statistical difference in their clearance rates. Preferential uptake of AlPcS2 by both tumors compared to contra-lateral flank subcutaneous normal tissue was documented, with ITu injection exceeding IV injection by a factor of 10 in the tumor to normal tissue ratio. Inter-animal standard deviation in the mean fluorescence was near 76% for both routes of administration, but estimates of the variation within tumor were near 16% standard deviation when a large sampling volume was used. In contrast, microscopic intra-tumor standard deviation in the mean estimate was near 76%, with IV injection, indicating that high heterogeneity exists in the photosensitizer concentration on a smaller distance scale. The inter-tumor variation was reduced by ITu injection, but at the expense of increasing intra-tumor variation.

Adenocarcinoma↗

Near-infrared imaging in the small animal brain: optimization of fiber positions.

We investigate fiber placement issues associated with a hybrid magnetic resonance imaging (MRI) near-infrared (NIR) imaging technique for small animal brain studies. Location of the optical fibers on the cranium is examined, with an emphasis on maximizing the recovered resolution and contrast in the region of interest, which in this case is the murine brain. In a series of simulation studies, singular value decomposition of the Jacobian is used in order to determine the measurement sites that provide the most information about the region of interest. The modeling results indicate that data collected using fibers arranged on one side of the head near the brain contain as much information about optical changes within the brain as those positioned equally spaced around the entire periphery of the head. Practical space limitation considerations favor the one-sided fiber array geometry in the case where the NIR acquisition is expected to occur simultaneously with MRI.

Animals↗

Quantitative analysis of near-infrared tomography: sensitivity to the tissue-simulating precalibration phantom.

A near-infrared (NIR) imaging system is evaluated as a diagnostic clinical tool to image total hemoglobin concentration and oxygen saturation within tissue. Calibration of this type of system requires measurement of the response at each detector and source location from a homogeneous tissue-simulating phantom. The effect of using calibration phantoms of varying composition, size, and optical properties is examined to determine how it affects the overall image accuracy. All of the calibration phantoms investigated result in accurate reconstruction of absorbing heterogeneities due to increased blood concentration with less than 4% standard deviation. Images from a patient with a biopsy-confirmed ductal carcinoma are also evaluated and found to be insensitive to the choice of calibration object, with only 1% variation between images generated with different calibration objects. The tumor total hemoglobin contrast is approximately 240% higher than the average total hemoglobin concentration in contralateral breast. Soft calibration phantoms, which mimic the elastic properties of human breast tissue, are also considered and found to diminish positioning errors in the fibers relative to the actual breast exam, thereby reducing the artifacts in the periphery of the reconstructed image.

Aged↗