PubMed Health⌕ Search

Biomedical subjects

Bruce H Weiller

Publications and source records attributed to Bruce H Weiller.

7 recordsLinked to original sources

Direct electrical measurement of the conversion of metal acetates to metal sulfides by hydrogen sulfide.

Copper acetate and related metal salt films react directly with hydrogen sulfide at room temperature to form metal sulfides, resulting in conductivity changes as large as 108. The observed changes in conductivity are related to the solubility product constant (Ksp) and the difference in conductivity between the metal salt and the resulting metal sulfide. A smaller Ksp indicates a more stable metal sulfide and, therefore, greater metal salt reactivity. Polyaniline nanofiber/metal salt composites were also examined and show metal sulfide conversion with changes in resistance up to 106. The direct electrical measurement of the conversion of metal salt to metal sulfide has the potential to be the basis of a new type of sensitive, thin-film chemical sensor.

Journal Article↗

Hydrogen sensors based on conductivity changes in polyaniline nanofibers.

Hydrogen causes a reversible decrease in the resistance of a thin film of camphorsulfonic acid doped polyaniline nanofibers. For a 1% mixture of hydrogen in nitrogen, a 3% decrease in resistance is observed (DeltaR/R = -3%). The hydrogen response is completely suppressed in the presence of humidity. In contrast, oxygen does not inhibit the hydrogen response. A deuterium isotope effect on the sensor response is observed in which hydrogen gives a larger response than deuterium: (DeltaR/R)H/(DeltaR/R)D = 4.1 +/- 0.4. Mass sensors using nanofiber films on a quartz crystal microbalance also showed a comparable deuterium isotope effect: DeltamH/DeltamD = 2.3 +/- 0.2 or DeltanH/DeltanD = 4.6 +/- 0.4 on a molar basis. The resistance change of polyaniline nanofibers is about an order of magnitude greater than conventional polyaniline, consistent with a porous, high-surface-area nanofibrillar film structure that allows for better gas diffusion into the film. A plausible mechanism involves hydrogen bonding to the amine nitrogens along the polyaniline backbone and subsequent dissociation. The inhibitory effect of humidity is consistent with a stronger interaction of water with the polyaniline active sites that bind to hydrogen. These data clearly demonstrate a significant interaction of hydrogen with doped polyaniline and may be relevant to recent claims of hydrogen storage by polyaniline.

Journal Article↗

Nanostructured polyaniline sensors.

The conjugated polymer polyaniline is a promising material for sensors, since its conductivity is highly sensitive to chemical vapors. Nanofibers of polyaniline are found to have superior performance relative to conventional materials due to their much greater exposed surface area. A template-free chemical synthesis is described that produces uniform polyaniline nanofibers with diameters below 100 nm. The interfacial polymerization can be readily scaled to make gram quantities. Resistive-type sensors made from undoped or doped polyaniline nanofibers outperform conventional polyaniline on exposure to acid or base vapors, respectively. The nanofibers show essentially no thickness dependence to their sensitivity.

Journal Article↗

Polyaniline nanofibers: facile synthesis and chemical sensors.

Polyaniline nanofibers with uniform diameters between 30 and 50 nm can be made in bulk quantities through a facile aqueous/organic interfacial polymerization method at ambient conditions. The nanofibers have lengths varying from 500 nm to several micrometers and form interconnected networks. Thin films made of the nanofibers have superior performance in both sensitivity and time response to vapors of acid (HCl) and base (NH3).

Journal Article↗

Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: assay development and surface roughness measurements.

The development of a new assay for lipoproteins by capillary electrophoresis in fused-silica capillaries and in glass microdevices is described in this paper. The separation of low-density (LDL) and high-density (HDL) lipoproteins by capillary zone electrophoresis is demonstrated in fused-silica capillaries with both UV absorption and laser-induced fluorescence detection. This separation was accomplished using Tricine buffer (pH 9.0) with methylglucamine added as a dynamic coating. With UV detection, LDL eluted as a relatively sharp peak with a migration time of approximately 11 min and HDL eluted as a broad peak with a migration time of 12.5 min. Fluorescence detection of lipoproteins stained with NBD-ceramide was used with the same buffer system to give comparable results. Furthermore, fluorescence staining of human serum samples yielded results similar to the fluorescently stained LDL and HDL fractions, showing that this method can be used to quantify lipoproteins in serum samples. The method was also used to detect lipoproteins in glass micro-CE devices. Very similar results were obtained in microdevices although with much faster analysis times, LDL eluted as a sharp peak at approximately 25 s and HDL as a broad peak at slightly longer time. In addition, higher resolution was obtained on chips. To our knowledge, these results show the first separation and detection of lipoproteins in a microfluidic device using native serum samples. Atomic force microscopy was used to characterize the rms surface roughness (Rq) of microfluidic channels directly. Devices with different surface roughness values were fabricated using two different etchants for Pyrex wafers with a polysilicon masking layer. Using 49% HF, the measured roughness is Rq = 10.9 +/- 1.6 nm and with buffered HF (NH4F + HF) the roughness is Rq = 2.4 +/- 0.7 nm. At this level of surface roughness, there is no observable effect on the performance of the devices for this lipoprotein separation.

Chromatography, Gel↗

Low-density lipoprotein analysis in microchip capillary electrophoresis systems.

Due to the mounting evidence for altered lipoprotein and cholesterol-lipoprotein content in several disease states, there has been an increasing interest in analytical methods for lipoprotein profiling for diagnosis. The separation of low- and high-density lipoproteins (LDL and HDL, respectively) has been recently demonstrated using a microchip capillary electrophoresis (CE) system [1]. In contrast to this previous study, the present report demonstrates that LDL analysis can be performed in an uncoated glass microchannel. Moreover, by adding sodium dodecyl sulfate (SDS) to the sample at a concentration well below the critical micellar concentration prior to injection, the LDL peak undergoes a focusing effect and exhibits an apparent efficiency of 2.2 x 10(7) plates/m. Laser light scattering experiments demonstrate that the low concentration of SDS used does not significantly alter lipoprotein particle size distribution within the time course that the analysis is performed. It is thus hypothesized that SDS nondisruptively coats LDL particles. The peak sharpening effect, observed only when SDS is added solely to the sample, is probably due to a mobility gradient created between the sample and the running buffer. The chip-based method demonstrated here has the potential for rapid analysis and sensitive detection of different LDL forms of clinical relevance.

Electrophoresis, Capillary↗