PubMed Health⌕ Search

Biomedical subjects

Bruce K Gale

Publications and source records attributed to Bruce K Gale.

10 recordsLinked to original sources

Solution-phase DNA mutation scanning and SNP genotyping by nanoliter melting analysis.

Solution-phase, DNA melting analysis for heterozygote scanning and single nucleotide polymorphism (SNP) genotyping was performed in 10 nl volumes on a custom microchip. Human genomic DNA was PCR amplified in the presence of the saturating fluorescent dye, LCGreen Plus, and placed within microfluidic channels that were created between two glass slides. The microchip was heated at 0.1 degrees C/s with a Peltier device and viewed with an inverted fluorescence microscope modified for photomulitiplier tube detection. The melting data was normalized and the negative first derivative plotted against temperature. Mutation scanning for heterozygotes was easily performed by comparing the shape of the melting curve to homozygous standards. Genotyping of homozygotes by melting temperature (T(m)) required absolute temperature comparisons. Mutation scanning of ATM exon 17 and CFTR exon 10 identified single base change heterozygotes in 84 and 201 base-pair (bp) products, respectively. All genotypes at HFE C282Y were distinguished by simple melting analysis of a 40-bp fragment. Sequential analysis of the same sample on the gold-standard, commercial high-resolution melting instrument HR-1, followed by melting in a 10 nl reaction chamber, produced similar results. DNA melting analysis requires only minutes after PCR and is a simple method for genotyping and scanning that can be reduced to nanoliter volumes. Microscale systems for performing DNA melting reduce the reagents/DNA template required with a promise for high throughput analysis in a closed chamber without risk of contamination.

DNA↗

Reduction of end effect-induced zone broadening in field-flow fractionation channels.

A channel configuration for the elimination of end effects in field-flow fractionation (FFF) channels is simulated and demonstrated for a microfabricated FFF system. In field-flow fractionation, the carrier liquid and sample particles are transferred from a point injection to the full breadth of the rectangular channel using a triangular end piece at the inlet. The nonuniformity in streamline length generated by this end piece results in an increased instrument-related plate height. An additional contribution from the end piece at the outlet of the channel further increases the total band broadening. This paper presents a novel approach to minimize end-effect contributions to plate height by fabricating microstructures in the channel end sections to redistribute the flow streams and force streamline lengths to be more uniform. Numerical analysis of the flow profile and sample dispersion (including spreading of particles due to diffusion and advection) is carried out to investigate the optimized microstructure column size, shape, and placement in the end pieces. The configuration obtained from the numerical simulation results is used to design a prototype device. Experimental measurement of the plate heights for this prototype with an on-chip impedance-based detector shows marked improvement in performance due to the presence of the microstructures in comparison to conventional FFF channel geometry with an average 50% reduction in plate height. The redesigned inlet triangle results in a uniform transition of the point-injected sample into a thin and straight band across the width of the channel at the start of the rectangular section of the fractionation channel.

Fractionation, Field Flow↗

Effect of carrier ionic strength in microscale cyclical electrical field-flow fractionation.

Recent work with cyclical electrical field-flow fractionation systems has shown promise for the technique as a separation and analysis tool, but little is understood about how the carrier composition in the system affects its capabilities. The electrical properties of microscale CyElFFF systems change when the carrier ionic conditions are altered, and it is well known that the effects of increasing ionic strength carriers on retention in normal ElFFF systems are severe. Specifically, retention levels fall significantly. Accordingly, this work seeks to understand the effect that increasing carrier ionic strength in CyElFFF has on nanoparticle retention in the channels. The retention of polystyrene particles in the CyElFFF microsystem is reported at various ionic strengths of ammonium carbonate and at a variety of pH levels. The experiments are compared to the theory of CyElFFF available in the literature. The results indicate that the ionic strength of the carrier has a significant impact on retention and that high ionic strength carrier solutions lead to poor performance of the CyElFFF system. These results have significant impact on the possible uses of the technique and its applications, especially in the biomedical arena.

Journal Article↗

Improved theory of cyclical electrical field flow fractionation.

Previously reported theories for cyclical electrical field flow fractionation (CyElFFF) are severely limited in that they do not account for diffusion, steric, or electric double layer effects. Experiments have shown that these theories overpredict the retention of particles in CyElFFF. In this work, we present a model for prediction of steric, diffusion, and electrical effects. The electrical double layer effects are treated using a lumped electrical circuit model that accounts for the field shielding by the electrical double layer formed at the electrode-carrier interface. The electrical effects are shown to dominate retention times and outweigh the contributions of diffusion and particle size. Detailed results from the simulations are presented in this work, and a comparison between the theoretical and experimental results obtained from the retentions of polystyrene particle standards is presented in this paper. The models are shown to correctly predict the retention of the polystyrene standards in CyElFFF with a reasonable error, while existing models are shown to have significant failings.

Electricity↗

Geometric scaling effects on instrumental plate height in field flow fractionation.

This paper examines geometric scaling models for field flow fractionation systems to understand how channel dimensions affect resolution and retention. Specifically, the changing contribution of the instrumental plate height during miniaturization of field flow fractionation (FFF) systems is reported. The work is directed towards determining the optimal geometrical parameters for miniaturization of field flow fractionation systems. The experimental relationship between channel height in FFF systems and instrumental plate heights is reported. FFF scaling models are modified to: (i) better clarify the dependence of plate height and resolution on channel height in FFF and (ii) include a more complete geometrical scaling analysis and model comparison in the low retention regime. Electrical field flow fractionation has been shown to benefit from miniaturization, so this paper focuses on that subtype, but surprisingly, the results also indicate the possibility of improvement in performance with miniaturization of other field flow fractionation systems including general FFF subtypes in which the applied field does not vary with channel height. This paper also discusses the potential role of more powerful microscale field flow fractionation systems as a new class of sample preparation units for micro-total-analysis systems (mu-TAS).

Fractionation, Field Flow↗

A microfabricated electrical SPLITT system.

A growing need for methods to analyze and prepare monodisperse nanoparticles on an industrial scale exists and may be solved by the application of split flow thin fractionation (SPLITT) at the microscale. Microfluidic systems of this type have the ability to separate nanoparticles with high precision in a continuous manner. A miniaturized SPLITT system can be fabricated using standard microfabrication technologies, works in a continuous mode, and can be used as a sample preparation instrument in a micro-total-analysis-system (micro-TAS). In this paper, a miniaturized electrical SPLITT system, which separates particles continuously based on electrophoretic mobility, has been characterized. The advantages of miniaturization have been elucidated. The various aspects of the micro SPLITT system discussed in this paper can be broadly classified into: micro SPLITT system design, fluidics modeling to refine the splitter arrangements, and experimental characterization of the SPLITT system. The design of the micro SPLITT system has been elucidated focusing on the two designs that were implemented. Fluid modeling, used to arrive at a new SPLITT design, was done using a commercially available CFD package to investigate behavior of the fluid in the microchannel with various splitter arrangements. Testing was done with nanoparticles of varying diameter and electrophoretic mobilities to verify the modeling results and demonstrate functionality of the SPLITT system. Particles eluted from both outlets of the SPLITT system were characterized using AFM and SEM to verify the function of the system.

Chemical Fractionation↗

Cyclical electrical field flow fractionation.

Cyclical electrical field flow fractionation (Cy/ElFFF) is demonstrated in a standard electrical field flow fractionation (ElFFF) channel for the first time. Motivation for the use of alternating current (AC) fields in a traditionally direct current (DC) technique are discussed. The function of the system over a wide range of operating conditions is explored and challenges associated with various operating conditions reported. Retention of polystyrene nanoparticle standards is accomplished and the effect of varying parameters of the applied field, such as voltage and frequency, are explored. The first separations using this technique are demonstrated. The experimental results are compared to analytical models previously reported in the literature. The general trend of the experimental results is similar to those predicted in theoretical models and possible reasons for discrepancies are elucidated. Suggestions are made for improving the separation and analysis method, and possible applications explored.

Electrophoresis↗

An integrated optical oxygen sensor fabricated using rapid-prototyping techniques.

This paper details the design and fabrication of an integrated optical biochemical sensor using a select oxygen-sensitive fluorescent dye, tris(2,2'-bipyridyl) dichlororuthenium(ii) hexahydrate, combined with polymeric waveguides that are fabricated on a glass substrate. The sensor uses evanescent interaction of light confined within the waveguide with the dye that is immobilized on an SU-8 waveguide surface. Adhesion of the dye to the integrated waveguide surface is accomplished using a unique process of spin-coating/electrostatic layer-by-layer formation. The SU-8 waveguide was chemically modified to allow the deposition process. Exposure of the dye molecules to the analyte and subsequent chemical interaction is achieved by directly coupling the fluid channel to the integrated waveguide. The completed sensor was linear in the dissolved oxygen across a wide range of interest and had a sensitivity of 0.6 ppm. A unique fabrication aspect of this sensor is the inherent simplicity of the design, and the resulting rapidity of fabrication, while maintaining a high degree of functionality and flexibility.

Journal Article↗

A microfabricated thermal field-flow fractionation system.

A microscale thermal field-flow fractionation (micro-TFFF) system has been designed, fabricated, and characterized. Motivation for miniaturization of TFFF systems was established by examining the geometrical scaling of the fundamental TFFF theory. Miniaturization of conventional macroscale TFFF systems was made possible through utilization of micromachining technologies. Fabrication of the micro-TFFF system was discussed in detail. The micro-TFFF system was characterized for plate height versus flow rate, single-component polystyrene retention, and multicomponent polystyrene separations. Retention, thermal diffusion coefficients, and maximum diameter-based selectivity values were extracted from separation data and found comparable with macroscale TFFF system results. Retention values ranged from 0.33 to 0.46. Thermal diffusion coefficients were between 3.0 x 10(-8) and 5.4 x 10(-8) cm2/s x K. The maximum diameter-based selectivity was 1.40.

Journal Article↗

Geometric scaling effects in electrical field flow fractionation. 2. Experimental results.

Geometric scaling of microelectrical field flow fractionation (micro-EFFF) systems is investigated experimentally and compared to theory and to macroscale EFFF systems. Experimental results are presented to demonstrate that the miniaturized system operates according to the scaling theory associated with the system. Demonstrated improvements in the channels include increased retention and resolution and decreased peak broadening, electrical time constants, relaxation time, power consumption, and sample size. Additionally, scaling effects related to the compression of separation zones in the miniaturized EFFF systems are discussed.

Electrodes↗