Cost-effectiveness of screening BRCA1/2 mutation carriers with breast magnetic resonance imaging.

CONTEXT: Women with inherited BRCA1/2 mutations are at high risk for breast cancer, which mammography often misses. Screening with contrast-enhanced breast magnetic resonance imaging (MRI) detects cancer earlier but increases costs and results in more false-positive scans. OBJECTIVE: To evaluate the cost-effectiveness of screening BRCA1/2 mutation carriers with mammography plus breast MRI compared with mammography alone. DESIGN, SETTING, AND PATIENTS: A computer model that simulates the life histories of individual BRCA1/2 mutation carriers, incorporating the effects of mammographic and MRI screening was used. The accuracy of mammography and breast MRI was estimated from published data in high-risk women. Breast cancer survival in the absence of screening was based on the Surveillance, Epidemiology and End Results database of breast cancer patients diagnosed in the prescreening period (1975-1981), adjusted for the current use of adjuvant therapy. Utilization rates and costs of diagnostic and treatment interventions were based on a combination of published literature and Medicare payments for 2005. MAIN OUTCOME MEASURES: The survival benefit, incremental costs, and cost-effectiveness of MRI screening strategies, which varied by ages of starting and stopping MRI screening, were computed separately for BRCA1 and BRCA2 mutation carriers. RESULTS: Screening strategies that incorporate annual MRI as well as annual mammography have a cost per quality-adjusted life-year (QALY) gained ranging from less than 45,000 dollars to more than 700,000 dollars, depending on the ages selected for MRI screening and the specific BRCA mutation. Relative to screening with mammography alone, the cost per QALY gained by adding MRI from ages 35 to 54 years is 55,420 dollars for BRCA1 mutation carriers, 130,695 dollars for BRCA2 mutation carriers, and 98,454 dollars for BRCA2 mutation carriers who have mammographically dense breasts. CONCLUSIONS: Breast MRI screening is more cost-effective for BRCA1 than BRCA2 mutation carriers. The cost-effectiveness of adding MRI to mammography varies greatly by age.

Adult↗

Investigation of proton density for measuring tissue temperature.

PURPOSE: To examine the temperature dependence of the proton density (PD) in both adipose and muscle tissues, and the application of the PD as a thermometry parameter in breast tissues. MATERIALS AND METHODS: Porcine fat samples and bovine muscle samples were successively heated to temperatures ranging from 30 degrees C to 76 degrees C and then cooled. They were then imaged with a dual-echo spin-echo sequence. T1 and T2 effects were carefully corrected from the images. The apparent PD (APD) in regions of interest (ROIs) and the sum of the APD in all pixels (Sum_APD) were measured and analyzed by linear regression. RESULTS: APD in adipose tissue is linear and reversible, and changes with a 0.3%/ degrees C to 0.45%/ degrees C temperature variation. The temperature coefficient of Sum_APD in adipose tissue is approximately 0.29%/ degrees C, as predicted from the Boltzmann distribution. However, the results in muscle tissue are more variable. There is an offset in both APD and Sum_APD between heating and cooling phases, as well as different temperature coefficients between these two phases. CONCLUSION: The Sum_APD in adipose tissue validates the 1/T dependence on temperature. The APD is a potentially useful parameter for fat thermometry; however, its application in muscle tissue requires further investigation.

Adipose Tissue↗

In vivo porcine liver radiofrequency ablation with simultaneous MR temperature imaging.

PURPOSE: To demonstrate in vivo MR-guided temperature mapping during radiofrequency (RF) ablation of the liver with a commercially available RF generator modified to allow simultaneous RF treatment and MRI. MATERIALS AND METHODS: A commercial RF generator was modified using passive filtering to allow the continuous application of the treatment current during MRI studies. A total of six ablations were performed with the device in vivo in three porcine livers, and imaging was concurrently performed using one of two different temperature mapping strategies. RESULTS: MR images acquired during RF ablation demonstrated no noticeable interference from the RF ablation device, which was operated at clinically relevant power levels. Temperature maps showed areas of heating that were consistent with the dimensions of the RF ablation probe, with some asymmetry (likely depending on the orientation of the probe and heat propagation effects), and some differences in heating-spot area stability depending on the specific temperature mapping strategy used. Lesions were visualized on post-ablation imaging and sectioning. CONCLUSION: The feasibility of performing RF ablation with a modified commercial RF generator simultaneously with MRI was demonstrated. Interference-free MR temperature maps were produced with both variable respiratory motion and mechanical ventilation, and showed the extent of heating as the ablation progressed.

Animals↗

An MRI-compatible semiautomated vacuum-assisted breast biopsy system: initial feasibility study.

PURPOSE: To develop an MR-compatible vacuum-assisted core needle breast biopsy system. MATERIALS AND METHODS: A vacuum-assisted breast biopsy system (Mammotome Hand Held; Ethicon Endo-Surgery, USA) was modified for freehand MRI-guided biopsy in an open, interventional 0.5-T scanner (Signa SP; GE, USA). Probes (11 gauge [G]) were fabricated without significant susceptibility artifact. These mate with an electromechanical hand piece and control system that were modified for use within the MRI scanner. A total of 62 breast lesions were simulated in the mammary tissues of six recently lactating sows by injecting between 0.1 and 1.0 mL of an aqueous gel containing dilute gadopentetate dimeglumine (Gd-DTPA) that formed a bright mass on T1-weighted imaging. RESULTS: Mechanical performance was satisfactory. Magnetic susceptibility and radiofrequency (RF) artifacts from the 11-G probe were negligible. T1-weighted fast spin echo (FSE) was used to guide biopsy. Up to eight samples were removed per lesion. Overall, 461 samples were obtained in 493 attempts (94%). Sample weights averaged 54 mg (N = 493) compared to 4.6 mg (N = 24) from 14-G titanium MRI-compatible needles. On average, 59% of the attempted samples yielded target lesion material. CONCLUSION: Preliminary results demonstrate the feasibility of a vacuum-assisted breast biopsy system in the MRI environment. Small 0.1-mL lesions can be biopsied without needle artifacts obscuring the target.

Animals↗

Contrast-enhanced MRI of ductal carcinoma in situ: characteristics of a new intensity-modulated parametric mapping technique correlated with histopathologic findings.

PURPOSE: To identify morphologic and dynamic enhancement magnetic resonance imaging (MRI) features of pure ductal carcinoma in situ (DCIS) by using a new intensity-modulated parametric mapping technique, and to correlate the MRI features with histopathologic findings. MATERIALS AND METHODS: Fourteen patients with pure DCIS on pathology underwent conventional mammography and contrast-enhanced (CE) MRI using the intensity-modulated parametric mapping technique. The MR images were reviewed and the lesions were categorized according to morphologic and kinetic criteria from the ACR BI-RADS-MRI Lexicon, with BI-RADS 4 and 5 lesions classified as suspicious. RESULTS: With the use of a kinetic curve shape analysis, MRI classified seven of 14 lesions (50%) as suspicious, including four with initial-rapid/late-washout and three with initial-rapid/late-plateau. Using morphologic criteria, MRI classified 10/14 (71%) as suspicious, with the most prominent morphologic feature being a regional enhancement pattern. Using the intensity modulated parametric mapping technique, MRI classified 12/14 cases (86%) as suspicious. Parametric mapping identified all intermediate- and high-grade DCIS lesions. CONCLUSION: The intensity-modulated parametric mapping technique for breast MRI resulted in the highest detection rate for the DCIS cases. Furthermore, the parametric mapping technique identified all intermediate- and high-grade DCIS lesions, suggesting that a negative MRI using the parametric mapping technique may exclude intermediate- and high-grade DCIS. This finding has potential clinical implications.

Adult↗

X-ray compatible radiofrequency coil for magnetic resonance imaging.

The range of RF coils that can be used in combined X-ray/MR (XMR) systems is limited because many conventional coils contain highly X-ray attenuating materials that are visible in the X-ray images and potentially obscure patient anatomy. In this study, an X-ray compatible coil design that has minimal X-ray attenuation in the field of view (FOV) of the X-ray image is presented. In this design, aluminum is used for the loop conductor and discrete elements of the coil are eliminated from the X-ray FOV. A surface coil and an abdominal phased array coil were built using the X-ray compatible design. X-ray attenuation and MR imaging properties of the coils were evaluated and compared to conventional coils. The X-ray compatible phased array coil was used to image patients during two interventional procedures in the XMR system. The X-ray compatible coils allowed for fluoroscopic X-ray image acquisition, without degradation by the coil, while maintaining excellent MR imaging qualities.

Aluminum↗

Truly hybrid X-ray/MR imaging: toward a streamlined clinical system.

RATIONALE AND OBJECTIVE: We have installed an improved X-ray/MR (XMR) truly hybrid system with higher imaging signal-to-noise ratio (SNR) and versatility than our first prototype. In our XMR design, a fixed anode X-ray fluoroscopy system is positioned between the two donut-shaped magnetic poles of a 0.5T GE Signa-SP magnet (SP-XMR). This paper describes the methods for increased compatibility between the upgraded x-ray and MR systems that have helped improve patient management. MATERIALS AND METHODS: A GE OEC 9800 system (GE OEC Salt Lake City, UT) was specially reconfigured for permitting X-ray fluoroscopy inside the interventional magnet. A higher power X-ray tube, a new permanent tube mounting system, automatic exposure control (AEC), remote controlled collimators, choice of multiple frame rates, DICOM image compatibility, magnetically shimmed X-ray detector, X-ray compatible MR coil, and better RF shielding are the highlights of the new system. A total of 23 clinical procedures have been conducted with SP-XMR guidance of which five were performed using the new system. RESULTS: The 70% increased power for fluoroscopy, and a new 6 times higher power single frame imaging mode, has improved imaging capability. The choice of multiple imaging frame rates, AEC, and collimator control allow reduction in X-ray exposure to the patient. The DICOM formatting has permitted easy transfer of clinical images over the hospital PACS network. The increased MR compatibility of the detector and the X-ray transparent MR coil has enabled faster switching between X-ray and MR imaging modes. CONCLUSION: The improvements introduced in our SP-XMR system have further streamlined X-ray/MR hybrid imaging. Additional clinical procedures could benefit from the new SP-XMR imaging.

Equipment Design↗

In vivo MR thermometry of frozen tissue using R2* and signal intensity.

Cryoablation is one of several minimally invasive treatments that may be suitable for a targeted treatment of prostate cancer. Because efficacy is improved when a sufficiently cold end temperature is reached, the purpose of this work was to demonstrate an image-based thermometry method that could provide temperature maps throughout the frozen tissue. In five in vivo canine prostate cryoablation experiments performed under magnetic resonance imaging guidance, two MR parameters were measured and correlated to temperature: R2* and changes in signal intensity. R2* is elevated approximately linearly as tissue temperature decreases below the freezing point, while the signal intensity decreases exponentially. In vivo temperature maps with isotherms at -5 degrees C, -15 degrees C, and -30 degrees C are demonstrated.

Animals↗

Pathologic correlates of false positive breast magnetic resonance imaging findings: which lesions warrant biopsy?

BACKGROUND: Contrast-enhanced breast magnetic resonance imaging (MRI) is highly sensitive for breast cancer. However, adoption of breast MRI is hampered by frequent false positive (FP) findings. Though ultimately proven benign, these suspicious findings require biopsy due to abnormal morphology and/or kinetic enhancement curves that simulate malignancy on MRI. We hypothesized that analysis of a series of FP MRI findings could reveal a pattern of association between certain "suspicious" lesions and benign disease that might help avoid unnecessary biopsy of such lesions in the future. METHODS: A retrospective chart review identified women undergoing breast MRI between June 1995 and March 2002 with FP findings identified by MRI alone. Lesions were retrospectively characterized according to an MRI Breast Imaging-Reporting and Data System lexicon and matched to pathology. RESULTS: Twenty-two women were identified with 29 FP lesions. Morphology revealed 1 focus (3.5%), 5 masses less than 5 mm (17%), 11 masses greater than 5 mm (38%), 1 (3.5%) linear enhancement, and 11 (38%) non-mass-like enhancement. Kinetic curves were suspicious in 15 (52%). Histology demonstrated 20 (69%) variants of normal tissue and 9 (31%) benign masses. MRI lesions less than 5 mm (n = 6, 20.5%) were small, well-delineated nodules of benign breast tissue. CONCLUSION: Suspicious MRI lesions less than 5 mm often represent benign breast tissue and could potentially undergo surveillance instead of biopsy.

Adult↗

Rates of reexcision for breast cancer after magnetic resonance imaging-guided bracket wire localization.

BACKGROUND: We performed this study to determine rates of close or transected cancer margins after magnetic resonance imaging-guided bracket wire localization for nonpalpable breast lesions. STUDY DESIGN: Of 243 women undergoing MRI-guided wire localizations, 26 had MRI bracket wire localization to excise either a known cancer (n = 19) or a suspicious MRI-detected lesion (n = 7). We reviewed patient age, preoperative diagnosis, operative intent, mammographic breast density, MRI lesion size, MRI enhancement curve and morphology, MRI Breast Imaging Reporting and Data System (BI-RADS) assessment code, number of bracket wires, and pathology size. We analyzed these findings for their relationship to obtaining clear margins at first operative excision. RESULTS: Twenty-one of 26 (81%) patients had cancer. Of 21 patients with cancer, 12 (57%) had negative margins at first excision and 9 (43%) had close/transected margins. MRI size > or = 4 cm was associated with a higher reexcision rate (7 of 9, 78%) than those < 4 cm (2 of 12, 17%) (p = 0.009). MRI BI-RADS score, enhancement curve, morphology, and preoperative core biopsy demonstrating ductal carcinoma in situ (DCIS) were not predictive of reexcision. The average number of wires used for bracketing increased with lesion size, but was not associated with improved outcomes. On pathology, cancer size was smaller in patients with negative margins (12 patients, 1.2 cm) than in those with close/transected margins (9 patients, 4.6 cm) (p < 0.001). Reexcision was based on close/transected margins involving DCIS alone (6, 67%), infiltrating ductal carcinoma and DCIS (2, 22%), or infiltrating ductal carcinoma alone (1, 11%). Reexcision pathology demonstrated DCIS (3, 33%), no residual cancer (5, 55%), and 1 patient was lost to followup (1, 11%). Interestingly, cancer patients who required reexcision were younger (p = 0.022), but breast density was not associated with reexcision. CONCLUSIONS: To our knowledge, this is the first report of MRI-guided bracket wire localization. Patients with MRI-detected lesions less than 4 cm had clear margins at first excision; larger MRI-detected lesions were more likely to have close/transected margins. Reexcision was often because of DCIS and was the only pathology found at reexcision, perhaps because MRI is more sensitive for detecting invasive carcinoma than DCIS.

Adult↗

MR-guided interventions of the breast.

Techniques and instrumentation are now widely available that enable interventional MR-guided preoperative needle localization and lesion marking. Minimally invasive MR-guided core biopsy techniques have been demonstrated but remain limited for small lesions and will be facilitated by the development of biopsy instruments that can be directly visualized using MR imaging. MR-guided tumor ablation is beginning to be evaluated in a few centers. It holds promise as new treatment modality in the continuing trend toward greater breast conservation in the local therapy of breast cancer. Further studies are needed to document the ability of MR-guided ablation to control the margins of a tumor as effectively as surgery. Patients with an extensive in situ intra-ductal component may pose a significant hurdle because the extent of ductal carcinoma in situ maybe underestimated on breast MR images. Ultimately, the success of MR-guided thermal ablation depends on the ability of MR imaging to map the extent of heating during the procedure so that the procedure can be performed to achieve complete control of the tumor margins. It is unfortunate that the conventional method for MR thermometry--the proton resonance frequency shift method--does not work in fat or in voxels with a mix of fat and glandular tissue and, hence, has limited applicability in the breast. Other methods, including measurement of T1 and T2, are being investigated as alternatives.

Biopsy, Needle↗

Magnetic resonance imaging characteristics of fibrocystic change of the breast.

OBJECTIVE: The objective of this study was to identify magnetic resonance imaging (MRI) characteristics of fibrocystic change (FCC) of the breast. MATERIALS AND METHODS: Fourteen patients with a histopathologic diagnosis of solitary FCC of the breast underwent x-ray mammography and MRI of the breast. Three experienced breast imaging radiologists retrospectively reviewed the MRI findings and categorized the lesions on morphologic and kinetic criteria according to the ACR BI-RADS-MRI Lexicon. RESULTS: The most striking morphologic feature of fibrocystic change was nonmass-like regional enhancement found in 6 of 14 (43%) FCC lesions. Based on morphologic criteria alone, 12 of 14 (86%) lesions were correctly classified as benign. According to analysis of the time-intensity curves, 10 of 14 (71%) FCC lesions were correctly classified as benign. CONCLUSION: Although FCC has a wide spectrum of morphologic and kinetic features on MRI, it most often presents as a mass or a nonmass-like regional enhancing lesion with benign enhancement kinetics.

Adult↗

MR-guided transjugular intrahepatic portosystemic shunt creation with use of a hybrid radiography/MR system.

PURPOSE: To evaluate the performance of a combined hybrid radiography/magnetic resonance (MR) unit to guide portal vein (PV) puncture during human transjugular intrahepatic portosystemic shunt (TIPS) creation. MATERIALS AND METHODS: Fourteen patients undergoing TIPS creation were studied during standard clinical applications. Patients were anesthetized and then positioned in an open MR unit containing a flat-panel radiographic fluoroscopic unit. With use of a combination of fluoroscopy and MR imaging, the PV was accessed and the TIPS procedure was performed. A noncovered nitinol stent or a covered stent-graft was placed in the TIPS tract. Number of punctures required, total procedure time, fluoroscopy time, procedural success rate, complications, and ultrasonographic and clinical follow-up were recorded. RESULTS: Clinical success was obtained in 13 of 14 patients. In one patient, extrahepatic puncture of the PV occurred, resulting in hemorrhage and requiring placement of a covered stent to control the bleeding. The mean number of punctures required to access the PV was 2.6 +/- 1.7, and the total procedure time was 2.5 hours +/- 0.6. Mean fluoroscopy time was 22.3 minutes +/- 5.5. Results of clinical and ultrasonographic follow-up compare favorably to previously published reports. CONCLUSION: TIPS creation with a combination hybrid radiography/MR unit is feasible and may reduce the number of needle passes required and radiation exposure, with similar overall outcomes compared with studies reported in the literature.

Alloys↗

Opinions of women with high inherited breast cancer risk about prophylactic mastectomy: an initial evaluation from a screening trial including magnetic resonance imaging and ductal lavage.

OBJECTIVE: Prophylactic mastectomy (PM) is often considered, but variably chosen by women at high inherited risk of breast cancer; few data exist on patient tolerance of intensive breast screening as an alternative to PM. We performed an evaluation of high-risk women's tolerance of a breast screening protocol using clinical breast examination, mammography, breast magnetic resonance imaging (MRI) and ductal lavage (DL), and of change in attitudes toward PM after screening. DESIGN: A questionnaire assessing tolerance of screening procedures and change in opinion towards PM was designed and administered to 43 study participants, after a median follow-up of 13 months. Responses were evaluated according to patient characteristics, including type of study-prompted interventions, BRCA mutation status, and prior history of cancer, via univariate analysis. RESULTS: Most patients [85.3% (68.9-95.1%)] were more opposed or unchanged in their attitudes towards PM after study participation, with only 14.7% (5.0-31.1%) less opposed (P = 0.017) despite a short-interval follow-up MRI rate of 71.7% and a biopsy rate of 37%. Lower rates of maximal discomfort were reported with mammogram [2.8% (0-14.5%)] and MRI [5.6% (0-18.7%)] than with DL [28.6% (14.6-46.3%)], with P = 0.035. CONCLUSIONS: Most high-risk women tolerated intensive breast screening well; they were not more inclined towards PM after participating. Future studies should prospectively evaluate larger numbers of high-risk women via multivariate analysis, to determine characteristics associated with preference for breast screening vs. PM.

Adult↗

The lactating breast: contrast-enhanced MR imaging of normal tissue and cancer.

PURPOSE: To retrospectively describe the magnetic resonance (MR) imaging characteristics of normal breast tissue and breast cancer in the setting of lactation. MATERIALS AND METHODS: The HIPAA-compliant study was exempt from institutional approval, and informed consent was not required. Unilateral MR imaging of 10 breasts was performed in seven lactating patients aged 27-42 years. For the three patients in whom both breasts were imaged, each breast was imaged on a separate day. Nonenhanced T1-weighted and fat-saturated T2-weighted images and contrast material-enhanced dynamic three-dimensional (3D) T1-weighted spiral gradient-echo images interleaved with T1-weighted high-spatial-resolution 3D gradient-echo images (2.0 x 1.0 x 0.4-mm voxels) were obtained. Three readers in consensus assessed the glandular density, T2-weighted signal intensity, milk duct appearance, and contrast enhancement in normal and tumor-containing breast regions. The pharmacokinetic contrast enhancement parameters of tumors were compared with those of normal tissue by using Student t and Mann-Whitney tests. RESULTS: MR findings of normal breast tissue in the seven women included increased glandular density in six women, high T2-weighted signal intensity in six, dilated central ducts in seven, and rapid initial glandular contrast enhancement in seven. MR findings of invasive ductal carcinoma in five women, compared with findings of the normal glandular tissue, included lower T2-weighted signal intensity in five women, more avid and rapid contrast enhancement in five, and early contrast enhancement washout in four. One minute after contrast agent injection, tumor signal intensity increased significantly more than normal lactating tissue signal intensity (153% vs 60% from baseline, P = .016). The median two-compartment model K(21) exchange rate in the tumors, 0.078 sec(-1), was significantly faster than the K(21) exchange rate in normal tissue, 0.011 sec(-1) (P = .03). CONCLUSION: Normal lactating glands have increased density, high T2-weighted signal intensity, and rapid moderate contrast enhancement. Breast cancers are visible during lactation owing to their lower signal intensity and more intense initial contrast enhancement with early washout compared with normal breast tissue.

Adult↗

Breast magnetic resonance image screening and ductal lavage in women at high genetic risk for breast carcinoma.

BACKGROUND: Intensive screening is an alternative to prophylactic mastectomy in women at high risk for developing breast carcinoma. The current article reports preliminary results from a screening protocol using high-quality magnetic resonance imaging (MRI), ductal lavage (DL), clinical breast examination, and mammography to identify early malignancy and high-risk lesions in women at increased genetic risk of breast carcinoma. METHODS: Women with inherited BRCA1 or BRCA2 mutations or women with a >10% risk of developing breast carcinoma at 10 years, as estimated by the Claus model, were eligible. Patients were accrued from September 2001 to May 2003. Enrolled patients underwent biannual clinical breast examinations and annual mammography, breast MRI, and DL. RESULTS: Forty-one women underwent an initial screen. Fifteen of 41 enrolled women (36.6%) either had undergone previous bilateral oophorectomy and/or were on tamoxifen at the time of the initial screen. One patient who was a BRCA1 carrier had high-grade ductal carcinoma in situ (DCIS) that was screen detected by MRI but that was missed on mammography. High-risk lesions that were screen detected by MRI in three women included radial scars and atypical lobular hyperplasia. DL detected seven women with cellular atypia, including one woman who had a normal MRI and mammogram. CONCLUSIONS: Breast MRI identified high-grade DCIS and high-risk lesions that were missed by mammography. DL detected cytologic atypia in a high-risk cohort. A larger screening trial is needed to determine which subgroups of high-risk women will benefit and whether the identification of malignant and high-risk lesions at an early stage will impact breast carcinoma incidence and mortality.

Adult↗