Comparison of standard- and low-radiation-dose CT for quantification of emphysema.

OBJECTIVE: This study was performed to compare standard- and low-radiation-dose techniques in the CT quantification of emphysema. MATERIALS AND METHODS: The study population consisted of 36 men and 20 women who were current or former heavy smokers and underwent standard-dose (effective tube current, 100-250 mAs) chest CT at our institution within 6 months of having undergone low-dose (effective tube current, 30-60 mAs) chest CT. All CT scans were reconstructed at 5-mm slice thickness with a smooth filter. CT-measured lung volume, mean and median lung attenuation, and percentage of lung volume with attenuation lower than multiple thresholds (emphysema index values) were compared by Pearson correlation, two-tailed and paired Student's t tests, and regression analysis. RESULTS: There were no significant differences in mean attenuation (-848 vs -846 H, p > 0.35) for the low dose and the standard dose or in median lung attenuation (-879 vs -878 H, p > 0.66). Low- and standard-dose emphysema indexes were correlated at all attenuation thresholds (r = 0.86-0.97). Mean emphysema indexes were higher on the low-dose scans, but the mean difference at all thresholds was less than 3%. The differences were significant (p < 0.05) only at the lower index thresholds, correlated with differences in lung volume (r < or = 0.86), and increased with greater differences in dose. CONCLUSION: Low-dose technique has minimal effect on CT quantification of emphysema.

Aged↗

Pose estimation of known objects during transmission tomographic image reconstruction.

We address the problem of image formation in transmission tomography when metal objects of known composition and shape, but unknown pose, are present in the scan subject. Using an alternating minimization (AM) algorithm, derived from a model in which the detected data are viewed as Poisson-distributed photon counts, we seek to eliminate the streaking artifacts commonly seen in filtered back projection images containing high-contrast objects. We show that this algorithm, which minimizes the I-divergence (or equivalently, maximizes the log-likelihood) between the measured data and model-based estimates of the means of the data, converges much faster when knowledge of the high-density materials (such as brachytherapy applicators or prosthetic implants) is exploited. The algorithm incorporates a steepest descent-based method to find the position and orientation (collectively called the pose) of the known objects. This pose is then used to constrain the image pixels to their known attenuation values, or, for example, to form a mask on the "missing" projection data in the shadow of the objects. Results from two-dimensional simulations are shown in this paper. The extension of the model and methods used to three dimensions is outlined.

Algorithms↗

Properties of preprocessed sinogram data in x-ray computed tomography.

The accurate determination of x-ray signal properties is important to several computed tomography (CT) research and development areas, notably for statistical reconstruction algorithms and dose-reduction simulation. The most commonly used model of CT signal formation, assuming monoenergetic x-ray sources with quantum counting detectors obeying simple Poisson statistics, does not reflect the actual physics of CT acquisition. This paper describes a more accurate model, taking into account the energy-integrating detection process, nonuniform flux profiles, and data-conditioning processes. Methods are developed to experimentally measure and theoretically calculate statistical distributions, as well as techniques to analyze CT signal properties. Results indicate the limitations of current models and suggest improvements for the description of CT signal properties.

Algorithms↗

On two-parameter models of photon cross sections: application to dual-energy CT imaging.

The goal of this study is to evaluate the theoretically achievable accuracy in estimating photon cross sections at low energies (20-1000 keV) from idealized dual-energy x-ray computed tomography (CT) images. Cross-section estimation from dual-energy measurements requires a model that can accurately represent photon cross sections of any biological material as a function of energy by specifying only two characteristic parameters of the underlying material, e.g., effective atomic number and density. This paper evaluates the accuracy of two commonly used two-parameter cross-section models for postprocessing idealized measurements derived from dual-energy CT images. The parametric fit model (PFM) accounts for electron-binding effects and photoelectric absorption by power functions in atomic number and energy and scattering by the Klein-Nishina cross section. The basis-vector model (BVM) assumes that attenuation coefficients of any biological substance can be approximated by a linear combination of mass attenuation coefficients of two dissimilar basis substances. Both PFM and BVM were fit to a modern cross-section library for a range of elements and mixtures representative of naturally occurring biological materials (Z = 2-20). The PFM model, in conjunction with the effective atomic number approximation, yields estimated the total linear cross-section estimates with mean absolute and maximum error ranges of 0.6%-2.2% and 1%-6%, respectively. The corresponding error ranges for BVM estimates were 0.02%-0.15% and 0.1%-0.5%. However, for photoelectric absorption frequency, the PFM absolute mean and maximum errors were 10.8%-22.4% and 29%-50%, compared with corresponding BVM errors of 0.4%-11.3% and 0.5%-17.0%, respectively. Both models were found to exhibit similar sensitivities to image-intensity measurement uncertainties. Of the two models, BVM is the most promising approach for realizing dual-energy CT cross-section measurement.

Absorptiometry, Photon↗

Reduction of motion blurring artifacts using respiratory gated CT in sinogram space: a quantitative evaluation.

Techniques have been developed for reducing motion blurring artifacts by using respiratory gated computed tomography (CT) in sinogram space and quantitatively evaluating the artifact reduction. A synthetic sinogram was built from multiple scans intercepting a respiratory gating window. A gated CT image was then reconstructed using the filtered back-projection algorithm. Wedge phantoms, developed for quantifying the motion artifact reduction, were scanned while being moved using a computer-controlled linear stage. The resulting artifacts appeared between the high and low density regions as an apparent feature with a Hounsfield value that was the average of the two regions. A CT profile through these regions was fit using two error functions, each modeling the partial-volume averaging characteristics for the unmoving phantom. The motion artifact was quantified by determining the apparent distance between the two functions. The blurring artifact had a linear relationship with both the speed and the tangent of the wedge angles. When gating was employed, the blurring artifact was reduced systematically at the air-phantom interface. The gated image of phantoms moving at 20 mm/s showed similar blurring artifacts as the nongated image of phantoms moving at 10 mm/s. Nine patients were also scanned using the synchronized respiratory motion technique. Image artifacts were evaluated in the diaphragm, where high contrast interfaces intercepted the imaging plane. For patients, this respiratory gating technique reduced the blurring artifacts by 9%-41% at the lung-diaphragm interface.

Air↗

Radiation dose in multidetector row computed tomography cardiac imaging.

Multidetector row computed tomography (MDCT) with its markedly improved temporal and spatial resolution has opened up a new opportunity in cardiac CT imaging. MDCT scanners are increasingly available and have become the preferred CT scanners for the entire spectrum of clinical CT examinations. As a consequence, the number of cardiac CT studies is continuously growing. Because cardiac CT studies involve considerable radiation doses, it is compelling for us to understand the radiation dose estimates associated with cardiac CT imaging. In this article, we review the concepts of radiation dose measurement in CT, discuss MDCT scan parameters affecting radiation exposure, and provide a reference summary of radiation dose estimates associated with MDCT cardiac imaging.

Heart↗

Visibility of trabecular structures in oral radiographs.

OBJECTIVES: To determine whether alveolar trabecular bone is visible and quantifiable in projection radiographs. Radiographic changes in oral trabecular bone have been studied as possible indications of bone loss, but in some previous studies, observed structures have been attributed entirely to the endosteal surface. METHODS: Computed radiography (CR) images of human mandibles in molar and pre-molar regions were compared with simulations calculated from high-resolution computed-tomography (CT) and micro-CT volumes. By digitally editing the CT volumes, the simulations were separated into trabecular and cortical components. High-pass-filtered CR images revealed structural details of cortical and trabecular bone. RESULTS: Trabecular bone constitutes as much as 38% of the total alveolar bone, and accounts for most of the observed alveolar fine structure. Several morphological types of fine structure can be distinguished. The noise in filtered images appears to be a meaningful measure of trabecular bone. CONCLUSION: Trabecular bone is highly visible in intraoral radiographs.

Alveolar Process↗

A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Breathing motion is a significant source of error in radiotherapy treatment planning for the thorax and upper abdomen. Accounting for breathing motion has a profound effect on the size of conformal radiation portals employed in these sites. Breathing motion also causes artifacts and distortions in treatment planning computed tomography (CT) scans acquired during free breathing and also causes a breakdown of the assumption of the superposition of radiation portals in intensity-modulated radiation therapy, possibly leading to significant dose delivery errors. Proposed voluntary and involuntary breath-hold techniques have the potential for reducing or eliminating the effects of breathing motion, however, they are limited in practice, by the fact that many lung cancer patients cannot tolerate holding their breath. We present an alternative solution to accounting for breathing motion in radiotherapy treatment planning, where multislice CT scans are collected simultaneously with digital spirometry over many free breathing cycles to create a four-dimensional (4-D) image set, where tidal lung volume is the additional dimension. An analysis of this 4-D data leads to methods for digital-spirometry, based elimination or accounting of breathing motion artifacts in radiotherapy treatment planning for free breathing patients. The 4-D image set is generated by sorting free-breathing multislice CT scans according to user-defined tidal-volume bins. A multislice CT scanner is operated in the ciné mode, acquiring 15 scans per couch position, while the patient undergoes simultaneous digital-spirometry measurements. The spirometry is used to retrospectively sort the CT scans by their correlated tidal lung volume within the patient's normal breathing cycle. This method has been prototyped using data from three lung cancer patients. The actual tidal lung volumes agreed with the specified bin volumes within standard deviations ranging between 22 and 33 cm3. An analysis of sagittal and coronal images demonstrated relatively small (<1 cm) motion artifacts along the diaphragm, even for tidal volumes where the rate of breathing motion is greatest. While still under development, this technology has the potential for revolutionizing the radiotherapy treatment planning for the thorax and upper abdomen.

Adult↗

Prospects for quantitative computed tomography imaging in the presence of foreign metal bodies using statistical image reconstruction.

X-ray computed tomography (CT) images of patients bearing metal intracavitary applicators or other metal foreign objects exhibit severe artifacts including streaks and aliasing. We have systematically evaluated via computer simulations the impact of scattered radiation, the polyenergetic spectrum, and measurement noise on the performance of three reconstruction algorithms: conventional filtered backprojection (FBP), deterministic iterative deblurring, and a new iterative algorithm, alternating minimization (AM), based on a CT detector model that includes noise, scatter, and polyenergetic spectra. Contrary to the dominant view of the literature, FBP streaking artifacts are due mostly to mismatches between FBP's simplified model of CT detector response and the physical process of signal acquisition. Artifacts on AM images are significantly mitigated as this algorithm substantially reduces detector-model mismatches. However, metal artifacts are reduced to acceptable levels only when prior knowledge of the metal object in the patient, including its pose, shape, and attenuation map, are used to constrain AM's iterations. AM image reconstruction, in combination with object-constrained CT to estimate the pose of metal objects in the patient, is a promising approach for effectively mitigating metal artifacts and making quantitative estimation of tissue attenuation coefficients a clinical possibility.

Algorithms↗