PubMed Health⌕ Search

Biomedical subjects

Bruce Steinberg

Publications and source records attributed to Bruce Steinberg.

3 recordsLinked to original sources

Alpha-contingent EEG feedback reduces SPECT rCBF variability.

EEG feedback methods, which link the occurrence of alpha to the presentation of repeated visual stimuli, reduce the relative variability of subsequent, alpha-blocking event durations. The temporal association between electro-cortical field activation and regional cerebral blood flow (rCBF) led us to investigate whether the reduced variability of alpha-blocking durations with feedback is associated with a reduction in rCBF variability. Reduced variability in the rCBF response domain under EEG feedback control might have methodological implications for future brain-imaging studies. Visual stimuli were randomly presented to seven subjects, contingent upon the occurrence of alpha (alpha-contingent stimulation (ACS)) or alpha-blocking (not-alpha-blocking-contingent stimulation (NACS)) events. We employed a within-subjects design. rCBF was measured from multiple, cortical and sub-cortical regions. The primary dependent variables were the Mean, Standard Deviation and the ratio of Mean/Standard Deviation of: 1) the alpha-blocking response durations and 2) the temporally summated rCBF responses within the Visual Associative regions of interest (ROIs). Additional within-subjects rCBF measures were derived to quantify the variance-reducing effects of ACS across multiple, distributed areas of the brain. Both EEG and rCBF measures demonstrated decreased variability under ACS. This improved control was seen for localized as well as anatomically distributed rCBF measures.

Adult↗

Noninvasive measurement of compartment syndrome.

This study compared the effectiveness of a commercially available invasive intracompartmental pressure measuring device with an investigational noninvasive hardness measuring device in 75 patients undergoing examination for possible compartment syndrome. Legs, forearms, thighs, and arms were tested. Pressure values and hardness ratios were compared to one another as continuous variables and to the clinical diagnosis of compartment syndrome as discrete variables. The compartment with the highest pressure reading within a limb diagnosed with compartment syndrome was compared to limbs without compartment syndrome. Due to the low specificity of the noninvasive measurement of hardness compared to the invasive pressure measurement (0.82 versus 0.96), this study does not support the use of the hardness monitor in the diagnosis of compartment syndrome.

Adolescent↗

Acute wrist injuries in the athlete.

The athlete represents a special population in which injuries can occur either from a single acute traumatic event or as part of a continuum of overuse that leads to osseous or soft tissue failure. The spectrum of overuse with superimposed acute trauma makes the evaluation of the upper extremity in the competitive athlete more challenging. The expectation of this population for quick, full, painless recovery, coupled with the desire to return to the sport that caused the injury, makes the treatment difficult as well. This article will discuss athletic injuries of the forearm and wrist with an emphasis on evaluation, treatment, and criteria for return to play.

Acute Disease↗