Bruno Madore

Publications and source records attributed to Bruno Madore.

7 recordsLinked to original sources

A new strategy for respiration compensation, applied toward 3D free-breathing cardiac MRI.

In thorax and abdomen imaging, image quality may be affected by breathing motion. Cardiac MR images are typically obtained while the patient holds his or her breath, to avoid respiration-related artifacts. Although useful, breath-holding imposes constraints on scan duration, which in turn limits the achievable resolution and SNR. Longer scan times would be required to improve image quality, and effective strategies are needed to compensate for respiratory motion. A novel approach at respiratory compensation, targeted toward 3D free-breathing cardiac MRI, is presented here. The method aims at suppressing the negative effects of respiratory-induced cardiac motion while capturing the heart's beating motion. The method is designed so that the acquired data can be reconstructed in two different ways: First, a time series of images is reconstructed to quantify and correct for respiratory motion. Then, the corrected data are reconstructed a final time into a cardiac-phase series of images to capture the heart's beating motion. The method was implemented, and initial results are presented. A cardiac-phase series of 3D images, covering the entire heart, was obtained for two free-breathing volunteers. The present method may prove especially useful in situations where breath-holding is not an option, for example, for very sick, mentally impaired or infant patients.

Artifacts↗

Extension of the UNFOLD method to include free breathing.

Unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD) is a method to reduce the data acquisition burden in dynamic MRI. The method works by forcing aliased signals to behave in specific ways through time, so that these unwanted signals can be detected and removed. Unexpected events in time, such as displacements caused by breathing, have the potential to disturb the temporal strategy and may affect UNFOLD's ability to suppress aliasing artifacts. This work presents an extension of the UNFOLD method to accommodate temporal encoding disruptions. While the main type of disruption considered here comes from respiratory motion, other types of disruption can be envisioned, such as departures from the usual UNFOLD k-space sampling scheme. This extended version of UNFOLD was incorporated into UNFOLD-sensitivity encoding (UNFOLD-SENSE), and should also be applicable to closely related methods such as temporal SENSE (TSENSE), k-t Broaduse Linear Acquisition Speed up Technique (k-t BLAST), and k-t SENSE. Five patients were imaged with a modified version of a myocardial-perfusion sequence, and UNFOLD was used either alone or in conjunction with SENSE to obtain an acceleration of 2.0 (in three patients) or 3.0 (in two patients). In both cases this extended version of UNFOLD was able to suppress artifacts caused by the presence of breathing motion.

Algorithms↗

Reduced field-of-view MRI with two-dimensional spatially-selective RF excitation and UNFOLD.

When the region of interest (ROI) is smaller than the object, one can increase MRI speed by reducing the imaging field of view (FOV). However, when such an approach is used, features outside the reduced FOV will alias into the reduced-FOV image along the phase-encoding direction. Reduced-FOV methods are designed to correct this aliasing problem. In the present study, we propose a combination of two different approaches to reduce the acquired FOV: 1) two-dimensional (2D) spatially-selective RF excitation, and 2) the unaliasing by Fourier-encoding the overlaps using the temporal dimension (UNFOLD) technique. While 2D spatially-selective RF excitation can restrict the spins excited within a reduced FOV, the UNFOLD technique can help to eliminate any residual aliased signals and thus relaxes the requirement for a long RF excitation pulse. This hybrid method was implemented for MR-based temperature mapping, and resulted in artifact-free images with a fourfold improvement in temporal resolution.

Abdomen↗

UNFOLD-SENSE: a parallel MRI method with self-calibration and artifact suppression.

This work aims at improving the performance of parallel imaging by using it with our "unaliasing by Fourier-encoding the overlaps in the temporal dimension" (UNFOLD) temporal strategy. A self-calibration method called "self, hybrid referencing with UNFOLD and GRAPPA" (SHRUG) is presented. SHRUG combines the UNFOLD-based sensitivity mapping strategy introduced in the TSENSE method by Kellman et al. (5), with the strategy introduced in the GRAPPA method by Griswold et al. (10). SHRUG merges the two approaches to alleviate their respective limitations, and provides fast self-calibration at any given acceleration factor. UNFOLD-SENSE further includes an UNFOLD artifact suppression scheme to significantly suppress artifacts and amplified noise produced by parallel imaging. This suppression scheme, which was published previously (4), is related to another method that was presented independently as part of TSENSE. While the two are equivalent at accelerations < or = 2.0, the present approach is shown here to be significantly superior at accelerations > 2.0, with up to double the artifact suppression at high accelerations. Furthermore, a slight modification of Cartesian SENSE is introduced, which allows departures from purely Cartesian sampling grids. This technique, termed variable-density SENSE (vdSENSE), allows the variable-density data required by SHRUG to be reconstructed with the simplicity and fast processing of Cartesian SENSE. UNFOLD-SENSE is given by the combination of SHRUG for sensitivity mapping, vdSENSE for reconstruction, and UNFOLD for artifact/amplified noise suppression. The method was implemented, with online reconstruction, on both an SSFP and a myocardium-perfusion sequence. The results from six patients scanned with UNFOLD-SENSE are presented.

Artifacts↗

Fast algorithms for GS-model-based image reconstruction in data-sharing Fourier imaging.

Many imaging experiments involve acquiring a time series of images. To improve imaging speed, several "data-sharing" methods have been proposed, which collect one (or a few) high-resolution reference(s) and a sequence of reduced data sets. In image reconstruction, two methods, known as "Keyhole" and reduced-encoding imaging by generalized-series reconstruction (RIGR), have been used. Keyhole fills in the unmeasured high-frequency data simply with those from the reference data set(s), whereas RIGR recovers the unmeasured data using a generalized series (GS) model, of which the basis functions are constructed based on the reference image(s). This correspondence presents a fast algorithm (and two extensions) for GS-based image reconstruction. The proposed algorithms have the same computational complexity as the Keyhole algorithm, but are more capable of capturing high-resolution dynamic signal changes.

Algorithms↗

New approach to 3D time-resolved angiography.

TRICKS is an acquisition and reconstruction method capable of generating 3D time-resolved angiograms. Arguably, the main problem with TRICKS is the way it handles the outer regions of the k-space matrix, leading to artifacts at the edges of blood vessels. An alternative to the data- processing stage of TRICKS, designed to better represent edges and small vessels, is presented here. A weakness of the new approach is an increased sensitivity to motion compared to TRICKS. Since this method can use the same data as TRICKS, a hybrid reconstruction method could conceivably be developed where the advantages of both approaches are combined. Magn Reson Med 47:1022-1025, 2002.

Feasibility Studies↗

Using UNFOLD to remove artifacts in parallel imaging and in partial-Fourier imaging.

In dynamic MRI, it is often difficult to achieve the acquisition speed required to resolve or freeze the temporal variations of the imaged object. Several MRI methods aim at speeding up the image acquisition process. Through assumptions and/or prior knowledge, these dynamic MRI methods allow part of the needed data to be calculated instead of acquired. For example, partial-Fourier imaging assumes that phase varies smoothly within the object, and parallel imaging (e.g., simultaneous acquisition of spatial harmonics (SMASH) and sensitivity encoding (SENSE)) uses prior knowledge about receiver-coil sensitivity. While these methods accelerate acquisition, they can introduce artifacts or amplify noise in doing so. The present work aims at accelerating image acquisition significantly, while introducing almost no artifacts or noise amplification. It is shown here that new, extra information is gained if dynamic MRI methods are modified so that the sampling function changes in specific ways from time-frame to time-frame. In other words, the set of k-space locations that are acquired (instead of calculated) changes with time. The present temporal strategy, based on the UNaliasing by Fourier-encoding the Overlaps in the temporaL Dimension (UNFOLD) method, can be incorporated into common dynamic MRI methods. Results with partial-Fourier, SMASH, and SENSE imaging are presented here, where UNFOLD's contribution is to very significantly reduce the artifact and/or amplified noise content. Used in this way, UNFOLD contributes indirectly, rather than directly to the improvement in image acquisition speed, as it allows companion methods to operate properly at greater acceleration settings than would otherwise be feasible.

Artifacts↗