PubMed Health⌕ Search

Biomedical subjects

Bryce MacMillan

Publications and source records attributed to Bryce MacMillan.

3 recordsLinked to original sources

Phantom materials for single point imaging pulse sequences.

The popularity of pure phase encode MRI techniques, including single point imaging (SPI), is steadily increasing, particularly in instances where the samples of interest are solid-like, or for other reasons possess short effective transverse relaxation times, T2*. As the interest in these techniques grows, so too does the need for a phantom material which is representative of this class of samples. The characteristics of such a phantom should include chemical and physical stability, straightforward preparation, high signal to noise ratio and relaxation times which are both easily manipulated and representative. To this end, we have developed a gelatin/sucrose-based gel which addresses the above criteria and behaves as a very flexible short T2* phantom. An order of magnitude variation in T1 and T2 can be achieved over a reasonable range of sucrose concentration. Even larger changes can be achieved with the addition of further doping agents.

Journal Article↗

Direct detection of hydrocarbon displacement in a model porous soil with magnetic resonance imaging.

The direct detection of hydrocarbon fluid and the discrimination of water through carbon-13 magnetic resonance imaging (MRI) would be a significant advance in many scientific fields including food, petrogeological, and environmental sciences. Carbon-13 MRI is a noninvasive analytical technique that has great potential for direct detection of hydrocarbons. However, the low natural abundance of carbon-13, low gyromagnetic ratio, and generically short transverse signal lifetimes in realistic porous media all conspire to hinder carbon-13 MRI. A multiple echo pure phase encode MRI technique introduced in this paper helps to overcome these limitations. As a pure phase encode technique, it is immune to artifacts arising from inhomogeneous B0 fields. It is also, by its nature, more quantitative than most MRI methods. Viscous hydrocarbon flow through a sand bed, a simple realistic porous medium, was used as our test system. Flow in this model system was driven by capillary suction. The detection limit, spatially resolved, was determined to be 26 mg.

Journal Article↗

Centric scan SPRITE magnetic resonance imaging.

Two rapid, pure phase encode, centric scan, Single Point Ramped Imaging with T1-Enhancement (SPRITE) MRI methods are described. Each retains the benefits of the standard SPRITE method, most notably the ability to image short T2* systems, while increasing the sensitivity and generality of the technique. The Spiral-SPRITE method utilizes a modified Archimedean spiral k-space trajectory. The Conical-SPRITE method utilizes a system of spirals mapped to conical surfaces to sample the k-space cube. The sampled k-space points are naturally Cartesian grid points, eliminating the requirement of a re-gridding procedure prior to image reconstruction. The effects of transient state behaviour on image resolution and signal/noise are explored.

Journal Article↗