Achilles tendons: clinical relevance of neovascularization diagnosed with power Doppler US.

PURPOSE: To evaluate the clinical relevance of neovascularization diagnosed with power Doppler ultrasonography (US) in Achilles tendons in patients with chronic achillodynia. MATERIALS AND METHODS: Forty consecutive patients (mean age, 52 years; age range, 30-72 years) were examined. US was performed bilaterally and repeated after 3 months. Shape and echogenicity were assessed with gray-scale US and vascularization with power Doppler US. All patients were treated conservatively. Clinical assessment was performed after 0, 3, and 6 months by using visual analogue scale (VAS) scores (0, no pain; 100, unbearable pain). The VAS scores were compared with the initial US findings, and analysis of variance was used for repeated measurements. RESULTS: Neovascularization was present in 30 of 55 painful tendons and in one of 25 asymptomatic tendons. The mean VAS scores at 0, 3, and 6 months, respectively, for tendons with neovascularization were 52, 26, and 20; those for tendons without neovascularization were 39, 19, and 18 (P =.15). Forty-eight painful and nine asymptomatic tendons were spindle shaped. The mean VAS scores at 0, 3, and 6 months, respectively, for the spindle-shaped tendons were 48, 25, and 20; those for normally shaped tendons were 33, 10, and 16 (P =.17). Thirty-five painful and four asymptomatic tendons were inhomogeneous. The mean VAS scores at 0, 3, and 6 months, respectively, for symptomatic inhomogeneous tendons were 54, 29, and 25; those for symptomatic homogeneous tendons were 32, 12, and 9 (P <.001). CONCLUSION: Although neovascularization is a specific sign for pain, it does not indicate an unfavorable outcome. Conversely, tendon inhomogeneity seems to be associated with an unfavorable outcome.

Achilles Tendon↗

Obstetric MR pelvimetry: reference values and evaluation of inter- and intraobserver error and intraindividual variability.

PURPOSE: To establish obstetric magnetic resonance (MR) pelvimetric reference values in a large study population and stratify them according to delivery modality and to determine the intra- and interobserver error and intraindividual variability of MR pelvimetric assessment in volunteers. MATERIALS AND METHODS: MR pelvimetric data were retrospectively reviewed in 781 women (mean age, 28.9 years +/- 5.2 [SD]) clinically referred, and the data were correlated to obstetric history to derive normative values. Five observers assessed results of multiple MR pelvimetric examinations in 10 female volunteers (mean age, 34.7 years +/- 6.0; eight nullipara, two primipara) to provide data for measurement error analysis. RESULTS: All values were higher in the spontaneous vaginal delivery subgroup (n = 100) and lower in the cesarean section or vacuum extraction subgroup (n = 130; intersubgroup difference, P <.001, Mann-Whitney U test). Pelvimetric parameters in the group undergoing spontaneous vaginal delivery were as follows: obstetric conjugate, 121.7 mm +/- 8.6; interspinous distance, 112.3 mm +/- 7.9; intertuberous distance, 120.6 mm +/- 11.3; transverse diameter, 129.5 mm +/- 8.7; and sagittal outlet, 115.8 mm +/- 9.9. In the volunteer study, intraobserver, interobserver, and intraindividual reliabilities were high for the obstetric conjugate (0.94-0.96), interspinous distance (0.92-0.95), and transverse diameter (0.95-0.98) but low for intertuberous distance (0.64-0.87) and sagittal outlet (0.66-0.85). CONCLUSION: Pelvimetric dimensions are smaller in women undergoing cesarean section or vacuum extraction than they are in those delivering vaginally. The pelvimetric parameters associated with the largest measurement errors are intertuberous distance and sagittal outlet.

Adolescent↗

Aortoiliac and renal arteries: prospective intraindividual comparison of contrast-enhanced three-dimensional MR angiography and multi-detector row CT angiography.

PURPOSE: To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERIALS AND METHODS: DSA, 3D MR angiography, and multi-detector row CT angiography were performed in 46 consecutive patients. A total of 769 arterial segments were analyzed for arterial stenosis by using a four-point grading system. Aneurysmal changes were noted. The time required for performing 3D reconstructions and image analysis of both MR and CT data sets was measured. Patient acceptance for each modality was assessed with a visual analogue scale. Statistical analysis of data was performed. RESULTS: Sensitivity of MR angiography for detection of hemodynamically significant arterial stenosis was 92% for reader 1 and 93% for reader 2, and specificity was 100% and 99%, respectively. Sensitivity of CT angiography was 91% for reader 1 and 92% for reader 2, and specificity was 99% and 99%, respectively. Differences between the two modalities were not significant. Interobserver and intermodality agreement was excellent (kappa = 0.88-0.90). The time for performance of 3D reconstruction and image analysis of CT data sets was significantly longer than that for MR data sets (P <.001). Patient acceptance was best for CT angiography (P =.016). CONCLUSION: There is no statistically significant difference between 3D MR angiography and multi-detector row CT angiography in the detection of hemodynamically significant arterial stenosis of the aortoiliac and renal arteries.

Aged↗

Interrater reliability of videofluoroscopic swallow evaluation.

The past two decades have brought an enormous widening of interest in and knowledge about swallowing disorders. The most frequently used technique for swallow evaluation is X-ray videofluoroscopy. Most interventions are based on this examination. Only a few studies assessing interobserver reliability of videofluoroscopy have been published. The aim of our study was to assess the interobserver reliability of videofluoroscopy for swallow evaluation. Fifty-one consecutive dysphagic patients referred for videofluoroscopy were entered into the study regardless of their underlying disorder. The first swallow (5 ml of a semisolid radio-opague contrast media) of each patient was assessed in the lateral projection by 9 independent, experienced observers from different international swallow centers. All studies were evaluated according to a standardized protocol sheet and the interobserver reliability was calculated. The interobserver reliabilities assessed as kappa coefficient for parameters of the oral and pharyngeal phase, for the temporal occurrence of penetration/aspiration, and for the location of bolus residue ranged from 0.01 to 0.56. High reliability with an intraclass coefficient of 0.80 was achieved only with the well defined penetration/aspiration score. Our study underlines the need for exact definitions of the parameters assessed by videofluoroscopy, in order to raise interobserver reliability. To date, only aspiration is evaluated with high reliability by videofluoroscopy, whereas the reliability of all other parameters of oropharyngeal swallow is poor.

Adult↗

Lymph node surgery in papillary thyroid carcinoma.

BACKGROUND: The impact of nodal disease remains controversial in papillary thyroid carcinoma (PTC). STUDY DESIGN: One surgeon treated 159 unselected patients, who were followed up for 1 to 27 years. We present a retrospective analysis with respect to nodal disease. Occult nodal disease was investigated, including metachronous nodal disease (mpN(1)) in primarily node negative patients (pN(0), clinical [c]N(0)). RESULTS: Therapeutic lymphadenectomies, prophylactic lymphadenectomies, or no lymphadenectomy were carried out in 42 (cN(1)), 29 (cN(0)), and 88 (cN(0)) patients, respectively, with stage pN(1) in 41 (98%), in 5 (17%), and in 2 (2.3%) patients, respectively (17% versus 2.3% p < 0.005). Sensitivity and specificity of clinical staging were 85% and 99%, respectively. More frequent prophylactic lymphadenectomy during the study period (p = 0.002) led to a nonsignificant increase in stage pN(1) (26% versus 30%). Immunohistochemistry led to upstaging of only 3% of histologically negative nodes and one (4%) pN(0) patient. Nodal recurrence occurred in 8 of 156 patients (5%) treated for cure, in 12% of pN(1) versus 3% of pN(0) cN(0) tumors (p = 0.009), in 15% of TNM high-versus 3% of low-risk patients (p = 0.006), and in 5% each of patients, younger than 45 and 45 years or more. In TNM high-risk patients, tumor-related survival was 50% for stage pN(1) versus 86% for stage pN(0), cN(0) (p = 0.03) (100% and 100% in low-risk patients). CONCLUSIONS: The rate of occult nodal disease might be relatively low, and it does not frequently progress to clinical recurrent disease. Clinical nodal status might be valid for deciding the extent and radicality of node dissection. Prophylactic (central) lymphadenectomy should be carried out without radicality-associated morbidity. Macroscopic nodal disease warrants more rigorous, compartment-oriented lymphadenectomy. There is no rationale for detection of occult disease and micrometastasis by frozen section or immunohistochemistry.

Adult↗

Respiration-induced attenuation artifact at PET/CT: technical considerations.

Combined positron emission tomographic (PET)/computed tomographic (CT) scanners allow the use of CT data for attenuation correction of PET images. Eight patients with cancer underwent PET/CT scanning. Transmission scanning was performed with conventional attenuation correction and with CT scanning during maximum inspiration and normal expiration. Image quality was visually compared and fluorine 18 activities were measured in volumes of interest in the lung and myocardium. Analysis of variance for repeated measures revealed a significant decrease (P =.0001) in measured activities between PET images corrected with CT data acquired during maximum inspiration and those corrected with the conventional attenuation correction method or with CT data acquired during normal expiration. Deep inspiration during CT can result in severe deterioration in the final PET image.

Adult↗

Evaluation of peripheral arterial bypass grafts with multi-detector row CT angiography: comparison with duplex US and digital subtraction angiography.

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Adult↗

Mechanical complications after myocardial infarction reliably predicted using C-reactive protein levels and lymphocytopenia.

We assessed the accuracy of C-reactive protein (CRP) levels and lymphocyte counts to predict a mechanical complication (MC) after myocardial infarction (MI). Within 10 years, we identified 36 patients with 39 echocardiographically confirmed MC within 30 days of MI: ventricular septal defect (17 cases), papillary muscle rupture (10 cases), and left ventricular free wall rupture (12 cases). They were compared to 41 controls with an uncomplicated hospital course after MI. Peak CRP levels and minimum relative lymphocyte counts obtained within 96 h of the acute MI (AMI) and before diagnosis of the complication were compared with clinical parameters. Prior to the MC, peak CRP levels were significantly higher (p < 0.001) and relative lymphocyte counts lower (p < 0.001) than in controls while creatine kinase levels did not differ (p = nonsignificant). Using multivariate logistic regression, the following score was identified to have excellent prognostic significance for MC: CRP (mg/l) - 10 x Lyc (%). The area under the receiver-operating characteristic curve was 0.90 +/- 0.05 (p < 0.001). Combined use of CRP levels and relative lymphocyte counts may be helpful in accurately predicting an MC after AMI and should therefore be routinely assessed.

Aged↗

Original report. Fetal cardiographic monitoring during 1.5-T MR imaging.

OBJECTIVE: The aim of this report was to determine the feasibility of fetal cardiotocography during MR imaging and the safety of 1.5-T MR imaging on the basis of fetal heart activity and fetal movements. CONCLUSION: Fetal cardiotocography is feasible during MR imaging using modified standard equipment. The use of 1.5-T MR imaging appears to be safe and to have no negative short-term effects on the heart rate or movement incidence of healthy third-trimester fetuses under our experimental conditions.

Adolescent↗

Patients with suspected meniscal tears: prevalence of abnormalities seen on MRI of 100 symptomatic and 100 contralateral asymptomatic knees.

OBJECTIVE: The purpose of this study was to evaluate the prevalence of MR abnormalities of the knee on the symptomatic and contralateral asymptomatic sides in patients with suspected meniscal tears. SUBJECTS AND METHODS. One hundred patients (mean age, 42.7 years; range, 18-73 years) referred for suspected meniscal tears were prospectively examined with MRI of both knees when the contralateral knee was asymptomatic. The prevalence of various types of meniscal tears and other MR abnormalities was determined. RESULTS: Meniscal tears were found in 57 symptomatic knees and in 36 contralateral asymptomatic knees. In those 57 patients with a meniscal tear on the symptomatic side, the prevalence of asymptomatic tears in the contralateral side was 63% (36/57). Horizontal or oblique meniscal tears were found medially in 32 and laterally in 11 symptomatic knees, and medially in 29 and laterally in eight asymptomatic knees. Radial, vertical, complex, or displaced tears were found medially in 18 and laterally in five symptomatic knees, and medially in five and laterally in none of the asymptomatic knees. Collateral ligament abnormalities were found in 53 symptomatic knees and in six asymptomatic knees. Pericapsular soft-tissue abnormalities were found in 64 symptomatic and in 12 asymptomatic knees. Edema-like bone marrow abnormalities were found in 36 symptomatic and in three asymptomatic knees. CONCLUSION: Horizontal or oblique meniscal tears are frequently encountered in both asymptomatic and symptomatic knees and may not always be related to symptoms. However, radial, vertical, complex, or displaced meniscal tears and abnormalities of the collateral ligaments, pericapsular soft tissues, and bone marrow are found almost exclusively on the symptomatic side and appear to be clinically more meaningful.

Adolescent↗

Assessing intrarater, interrater and test-retest reliability of continuous measurements.

In this paper we review the problem of defining and estimating intrarater, interrater and test-retest reliability of continuous measurements. We argue that the usual notion of product-moment correlation is well adapted in a test-retest situation, whereas the concept of intraclass correlation should be used for intrarater and interrater reliability. The key difference between these two approaches is the treatment of systematic error, which is often due to a learning effect for test-retest data. We also consider the reliability of a sum and a difference of variables and illustrate the effects on components. Further, we compare these approaches of reliability with the concept of limits of agreement proposed by Bland and Altman (for evaluating the agreement between two methods of clinical measurements) and show how product-moment correlation is related to it. We then propose new kinds of limits of agreement which are related to intraclass correlation. A test battery to study the development of neuro-motor functions in children and adolescents illustrates our purpose throughout the paper.

Child↗

Follow-up of women with breast cancer: comparison between MRI and FDG PET.

The aim of this study was to compare MRI of the breast with (18)F-fluoro-deoxy-glucose (FDG) positron emission tomography (PET) in patients with suspected local or regional breast cancer recurrence or suspected contralateral breast cancer. Thirty-two patients (mean age 57.2 years, age range 32-76 years) with suspected loco-regional recurrence ( n=19), chest wall recurrence ( n=5), and suspected secondary tumor of the contralateral breast ( n=8) underwent MRI of the breast and FDG PET of the whole body and breast region. Cytology/histology ( n=17) or a clinical follow-up examination ( n=15) with additional imaging served as the standard of reference. A McNemar test was performed to compare PET and MRI, and kappa was determined to quantify agreement of both methods. Sensitivity was 79 and 100%, specificity was 94 and 72%, and accuracy was 88 and 84% for MRI and PET, respectively. Additional metastases outside the field of view of MRI were found in PET in 5 patients. In this study both imaging methods had comparable accuracy. The detection of distant metastases with whole-body PET imaging can influence patient management.

Breast Neoplasms↗

PET/CT of the abdomen: optimizing the patient breathing pattern.

The aim of this study was to evaluate the respiration position, which is optimal for co-registration of abdominal CT images, and the corresponding positron emission tomography (PET) scan in a new combined PET/CT system. Ten patients (5 men, 5 women; age 57.7+/-15.3 years, age range 34-80 years) underwent imaging for tumor staging on a combined PET/CT scanner (Discovery LS, GE Medical Systems, Milwaukee, Wis.). The PET emission images were acquired during normal shallow breathing and during CT scanning the patients performed four different breathing tasks: free breathing (FB); maximum inspiration (MaxInsp); maximum expiration (MaxExp); and normal expiration (NormExp). NormExp was defined as the respiratory level that was reached when the patient first inhaled and then exhaled without forcing expiration, and then held the breath in this position. Movements of the spleen, liver, left and right kidney, and the bladder were measured by using the promontory of the sacrum as a reference point and measuring the distance from this point to the abdominal organs in the PET and CT images by two independent observers. Statistical comparison of the measured distances between the CT scans and the PET scan were made using a Wilcoxon signed-rank test with Bonferroni correction. Repeated-measures analysis of variance served for the assessment of intraobserver and interobserver agreement. There was no significant difference between NormExp and FB indicating that both respiration protocols are suitable for PET/CT image co-registration of abdominal studies. In contrast, the MaxExp and MaxInsp protocol are not suitable. The NormExp and FB respiration protocol are both suitable for the co-registration of abdominal PET/CT studies. In most patients the mismatch of abdominal organs will be lower than the resolution of the final co-registered PET/CT image.

Abdominal Neoplasms↗

Evaluation of brain toxicity following near infrared light exposure after indocyanine green dye injection.

Indocyanine green (ICG) has excellent safety records and is widely used in medical diagnosis. Recently, a new method has been developed to estimate cerebral blood flow (CBF) using ICG in combination with near-infrared spectroscopy (NIRS). The new technique may be of wide clinical interest, as it is noninvasive and easy to perform at the bedside in stroke patients. Additionally, ICG with the use of specific wavelength lasers is documented to be effective in photodynamic therapy (PDT). Under normal conditions ICG does not cross the intact blood brain barrier (BBB). However, in patients with brain injuries where the BBB may be disturbed, ICG could accumulate in brain parenchyma and in combination with NIR-light exposure, phototoxicity could occur. The aim of the present study was to examine the possible toxicity of ICG in combination with NIRS in a specific setting for CBF measurements. In five rats with mannitol induced BBB breakdown no traces of ICG were found during spectrophotometric analysis of the brain cell suspensions. In ten rats with disrupted BBB there were no significant increases of brain temperature or histological signs of brain damage following 1 h NIR-light exposure after ICG injection. The existing literature concerning the application of ICG in combination with NIR light is reviewed.

Animals↗

Pelvimetry and patient acceptability compared between open 0.5-T and closed 1.5-T MR systems.

Our objective was to compare maternal pelvimetry and patient acceptability between open low-field (0.5-T) and closed 1.5-T MR systems. Thirty women referred for pelvimetry (pregnant: n=15) were scanned twice in the supine position, once in the vertical open system and once in the closed system. Each patient completed a comfort and acceptability questionnaire. Pelvimetric and questionnaire data were compared between systems. Total scan time was double in the open system (7:52+/-1:47 vs 3:12+/-1:20 min). Poor image quality in the open system prevented assessment of interspinous and intertuberous diameters in one woman and all measurements in another, both pregnant, with abdominal circumferences >120 cm. The open system was much more acceptable in terms of claustrophobia and confinement (both p<0.01). Claustrophobia interrupted one closed examination. Thirty-three percent of pregnant women in both systems reported fear of fetal harm. Sixty percent of all women preferred the open system, 7% the closed system, and 33% had no preference. Limits of agreement of 3-5% from the mean for all diameters confirmed good pelvimetric reproducibility. Women's preference for open-system MR pelvimetry is feasible with abdominal circumferences <or=120 cm.

Abdominal Cavity↗

Incidence of the superficial fascia and its relevance in skin-sparing mastectomy.

BACKGROUND: With the move away from classical radical mastectomy to ever more skin-sparing procedures, there has been an ongoing discussion about how much skin and subcutaneous tissue should be resected to perform an adequate mastectomy while leaving viable skin flaps. One of the common recommendations is to dissect just superficial to the superficial layer (SL) of the superficial fascia of the breast. This, in turn, has revived the old, unsolved controversy about the existence or absence of the SL, a fascia that reportedly encloses the mammary gland ventrally. In skin-sparing mastectomies (SSM), which combine tumor resection with immediate breast reconstruction, the ideal would be to create skin flaps that are thin enough to remove all breast tissue but at the same time are thick enough to preserve flap circulation. The feasibility of meeting these two goals simultaneously and the possible role and relevance of the SL as a guide to dissection in SSM was examined in this study. METHODS: Sixty-two breast resection specimens from 31 women who underwent breast reduction were examined histologically to determine whether the SL was present, whether breast tissue could be detected within or beyond this SL, the measured distance between the caudal border of the dermis and the SL or the breast tissue, and whether the thickness of the subcutaneous fat layer was correlated with the patients' physical data, such as body weight or body mass index (BMI). RESULTS: The SL was absent in 44% of resection specimens. When the SL was present, 42% of specimens contained several islands of breast tissue within the SL. No breast tissue was found beyond the SL. The minimal distance between the SL and the dermis varied from 0.2 mm to 4.0 mm; the minimal distance between the breast tissue and the dermis was 0.4 mm. In 50% of specimens, the minimal distance between the dermis and the SL or breast tissue was < 1.1 mm. A distance of > or = 5 mm was encountered in only 17% of specimens, and a distance of > or = 10 mm was encountered in only 5% of specimens. No significant correlation between the right and left breast was found with any of the parameters examined. A weak negative correlation was seen between the BMI and the mean thickness of the subcutaneous fat (P = 0.049; correlation coefficient [r] = -0.39; Spearman rank correlation). CONCLUSIONS: Histologic evaluation revealed that the SL is not present in all breasts and, thus, cannot serve as a reliable plane of dissection. Furthermore, if the SL is present microscopically, then it often is too thin and delicate to be detectable macroscopically. Finally, even if the SL is present and visible macroscopically, the distance to the overlying skin is so small in the majority of patients that a dissection superficial to the SL would not leave viable skin flaps in skin-sparing mastectomies.

Adult↗

Remodelling after surgical repair of atrial septal defects within the oval fossa.

In a retrospective study, we analysed the data from 101 adults with echocardiographic follow-up after surgical repair of defects within the oval fossa at a mean age of 35 +/- 17 years; 56% of the cohort being above the age of 30 years. Mean age at follow-up was 44 +/- 18 years, and length of follow-up was up to 40 years (11 +/- 12 years). At follow-up, atrial fibrillation or flutter was present in one quarter. Dilation of the right atrium, found in 64%, of the left atrium, found in 44%, and of the right ventricle, found in 29%, were also frequent, as well as pulmonary arterial hypertension, which was found in 30%. Diminished right ventricular ejection fraction, in contrast, was very rare, found only in 1%, and abnormal left ventricular ejection fraction was not encountered. By multivariate analysis, predictors for right or left atrial, or right ventricular, dilation were age at follow-up, degree of tricuspid regurgitation, pulmonary hypertension, and/or atrial fibrillation. In a subset of 21 patients in sinus rhythm, we correlated prospectively the diastolic and systolic function of both ventricles with levels of brain natriuretic peptide, comparing values to those of 20 age-matched controls with a mean age of 46 +/- 14 years. Levels of brain natriuretic peptide were significantly higher in patients than in controls (p = 0.006), and correlated significantly with diastolic dysfunction (p = 0.007) and left atrial size (p < 0.0001). In the long-term follow-up after surgical repair of defect within the oval fossa, therefore, complete normalization of heart size and function is rare. Despite preserved systolic function, persistent diastolic dysfunction is common and is associated with elevated levels of brain natriuretic peptide, which may explain the late occurrence of atrial arrhythmias.

Adolescent↗

Osteoporosis before lung transplantation: association with low body mass index, but not with underlying disease.

Due to progress in lung transplantation, post-transplantation osteoporosis becomes an important problem. We determined bone mineral density (BMD) in 74 lung transplantation candidates, among them 24 patients with cysticfibrosis, 16 with chronic obstructive pulmonary disease, 14 with pulmonary fibrosis, and 11 with pulmonary hypertension. The mean T score (+/- SD) was -2.6 +/- 1.3 at femoral neck (FN), -2.2 +/- 1.6 at Ward's triangle (WT) and -2.3 +/- 1.5 at lumbar spine (LS). Osteoporosis was found in 61% of the patients at FN, 45% at WT and 50% at LS. Patients with different underlying lung diseases were similarly affected, not only those with cystic fibrosis but also others, including patients with pulmonary hypertension. No association was found between BMD and age, gender, menstrual condition in women and testosterone level in men. A negative correlation was found between chronic glucocorticoid use and T scores. Body mass index correlated positively (p < 0.01) with T scores at any site and the correlation was also significant for the 2 largest subgroups. Loss of lung function (FEV1) also was associated with lower T scores. No correlation was found between BMD and biochemical indices of bone turnover. Multivariate analysis revealed BMI and glucocorticoid use as independent risk factors. We conclude that osteoporosis is a very common condition in patients with end-stage pulmonary disease, independent of the underlying diagnosis. In view of additional bone loss under immunosuppressive treatment after lung transplantation, early diagnosis and prevention of osteoporosis in the pretransplant period should receive high priority.

Absorptiometry, Photon↗