Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis.

A fully integrated genomic analysis microsystem including microfabricated heaters, temperature sensors, and PCR chambers directly connected to capillary electrophoretic separation channels has been constructed. Valves and hydrophobic vents provide controlled and sensorless sample positioning and immobilization into 200 nL PCR chambers. The use of microfabricated heating and temperature sensing elements improves the heating and cooling rates for the PCR reaction to 20 degree C s(-1). The amplified PCR product, labeled on-column with an intercalating fluorescent dye, is injected into the gel-filled capillary for electrophoretic analysis. Successful sex determination using a multiplex PCR reaction from human genomic DNA is demonstrated in less than 15 min. This device is an important step toward a microfabricated genomic microprocessor for use in forensics and point-of-care molecular medical diagnostics.

DNA↗

High-performance genetic analysis using microfabricated capillary array electrophoresis microplates.

This review focuses on some recent advances in realizing microfabricated capillary array electrophoresis (microCAE). In particular, the development of a novel rotary scanning confocal fluorescence detector has facilitated the high-speed collection of sequencing and genotyping data from radially formatted microCAE devices. The concomitant development of a convenient energy-transfer cassette labeling chemistry allows sensitive multicolor labeling of any DNA genotyping or sequencing analyte. High-performance hereditary haemochromatosis and short tandem repeat genotyping assays are demonstrated on these devices along with rapid mitochondrial DNA sequence polymorphism analysis. Progress in supporting technology such as robotic fluid dispensing and batched data analysis is also presented. The ultimate goal is to develop a parallel analysis platform capable of integrated sample preparation and automated electrophoretic analysis with a throughput 10-100 times that of current technology.

Electrophoresis, Capillary↗

High-pressure gel loader for capillary array electrophoresis microchannel plates.

Microfabricated capillary array electrophoresis (microCAE) microchannel plates are the next generation of bioanalytical separation devices. To fully exploit the capabilities of microCAE devices, supporting technology such as robotic sample loading, gel loading, microplate washing, and data analysis must be developed. Here, we describe a device for loading gel into radial capillary array electrophoresis microplates and for plate washing and drying. The microplates are locked into a loading module, and high-pressure helium is used to drive aqueous separation media or wash solutions into the microchannels through fixtures connected to the central anode reservoir. Microplates are rapidly (30 s to 5 min) loaded with separation media, such as 3%-4.8% linear polyacrylamide or 0.7%-3.0% hydroxyethyl cellulose, for electrophoresis. The effective and rapid gel-filling and plate-cleaning methods together with short electrophoretic analysis times (2-30 min) make microCAE systems versatile and powerful nucleic acid analysis platforms.

Electrophoresis, Capillary↗

Genotyping energy-transfer-cassette-labeled short-tandem-repeat amplicons with capillary array electrophoresis microchannel plates.

BACKGROUND: Genetic analysis of microsatellite DNA is a powerful tool used in linkage analysis, gene mapping, and clinical diagnosis. To address the expanding needs of studies of short tandem repeats (STRs), we demonstrated high-performance STR analysis on a high-throughput microchannel plate-based platform. METHODS: Energy-transfer-cassette-labeled STR amplicons were separated and typed on a microfabricated 96-channel radial capillary array electrophoresis (CAE) microchannel plate system. Four-color detection was accomplished with a laser-excited confocal fluorescence rotary scanner. RESULTS: Multiplex STR analysis with single base-pair resolution was demonstrated on denaturing polyacrylamide gel media. The high-throughput multiplex capabilities of this genetic analysis platform were demonstrated by the simultaneous separation of STR amplicons representing 122 samples in ninety-six 5.5-cm-long channels in <8 min. Sizing values obtained for these amplicons on the CAE microchannel plate were comparable to those measured on a conventional commercial CAE instrument and exhibit <1% sizing variance. CONCLUSIONS: Energy-transfer-cassette labeling and microfabricated CAE microchannel plates allow high-performance multiplex STR analyses.