C A González-Correa

Publications and source records attributed to C A González-Correa.

5 recordsLinked to original sources

Electrical bioimpedance readings increase with higher pressure applied to the measuring probe.

Electrical bioimpedance spectroscopy (EBIS) is a technique that uses a probe to calculate the transfer impedance from tissues. This transfer impedance can give information about the normal or pathological condition of the tissue. To take readings, pressure has to be applied to the probe in order to get a good contact between the electrodes and the tissue. We have been using EBIS to investigate the early diagnosis of dysplasia and cancer in the human cervix, oesophagus and bladder. We have found that, with increasing pressure (range used here was approximately 1 kPa to approximately 50 kPa), the resistivity readings increase in a consistent way up to 80%. In this paper, we show how this is a case in three different tissue types (oesophageal, gastric and vesical samples). These increases can be higher than those associated with the pathological changes that we are investigating (non-inflamed columnar tissue, for instance, shows values 50% higher than dysplastic columnar tissue). Finite-element modelling was also used to investigate the effect of volume reduction in the connective tissue or stroma. This simulation suggests no strong correlation between reduction of this structure and increase in resistivity. We hypothesize therefore that these changes may be mainly associated with the squeezing of water from the extracellular space. Finally, as pressure is difficult to control by hand, we raise the issue of the necessity of considering this variable when making EIS measurements.

Animals↗

Resistivity changes in conductive silicone sheets under stretching.

This paper reports a preliminary finding associated with an investigation of how tissues respond to mechanical stress. The stress distribution within the tissue may be the result of normal function, for example, joint forces, or it may result from interventions such as tissue suturing during or after surgery. We sought to combine electrical and mechanical computational models in order to better understand the interaction between the two. For example, if mechanical stress is applied to tissue this may change the cell arrangements within the tissue matrix and hence change the electrical properties. If this interaction could be determined, then it should be possible to use electrical impedance tomography measurements to identify stress patterns in tissues. Measurements of resistivity changes have been made in conductive silicone rubber sheets when subject to a uniaxial stress of up to 10%. Relatively large changes in resistivity are produced (up to 200%). These changes are far larger than those predicted arising from topological changes alone. It is suggested that under stress the conductive islands of carbon within the silicone rubber sheet undergo a reversible disassociation from their neighbours and that the material's electrical properties change under load. If similar stress-resistivity relationships occur within biological materials it may be possible to recover the stress fields within tissues from transfer impedance measurements and thereby predict if actions such as inappropriate suture tension will compromise tissue viability.

Algorithms↗

Assessing the conditions for in vivo electrical virtual biopsies in Barrett's oesophagus.

It has previously been shown that it is possible to differentiate between squamous and columnar epithelia in rat and resected human tissues using an impedance probe to make in vitro measurements. This probe can be passed down an endoscope allowing measurements to be made in patients. However, the probe emerges parallel to the oesophageal wall, with little room to manoeuvre. The conditions of control required to give reliable readings have been investigated. The importance of pressure applied and the angle of approach to the oesophagus was assessed. Pressures in the range 26.6 Pa to 46.3 kPa and angles in the range 15-90 degrees were considered. In in vitro studies it was observed that it was possible to obtain consistent readings with pressures greater than 2.9 kPa and with angles greater than 15 degrees between the probe and the oesophagus. These conditions can be achieved in vivo, and readings obtained from twelve patients are shown (45 readings on normal squamous, 34 on Barrett's oesophagus and 22 on stomach). At low frequencies (9.6-153.2 kHz), a Mann-Whitney test shows a significant difference (p < 0.001) when comparing the means from squamous and columnar, and also when readings from Barrett's and normal gastric epithelia are compared (p < 0.001).

Animals↗

Virtual biopsies in Barrett's esophagus using an impedance probe.

Preliminary results of electrical impedance measurements in squamous and columnar epithelia in rat and human tissues are presented. The aim of this work is to show the possibility of differentiating these two types of epithelia in terms of their electrical characteristics. For the measurements, we employed a 1.95-m-long, 3.2-mm-diameter, four-electrode probe designed to be used transendoscopically in the diagnosis of Barrett's esophagus (BE). BE is a condition in which the normal squamous epithelium of the esophagus is replaced by columnar epithelium of the intestinal type. This metaplasia is considered as a premalignant condition that puts patients at a 30-125-fold risk of developing adenocarcinoma of the esophagus. The diagnosis and surveillance of BE involve taking multiple biopsies, an expensive and time-consuming procedure. This study constitutes the first stage in the replacement of tissue biopsy by "virtual biopsies".

Animals↗

Assessment and calibration of a low-frequency system for electrical impedance tomography (EIT), optimized for use in imaging brain function in ambulant human subjects.

An EIT system has been produced that has been optimized for imaging impedance changes with scalp electrodes during brain activity in ambulant subjects. It can record from 225 Hz to 65 kHz, has a small headbox on a lead 10 m long, and has software programmable electrode selection. In calibration experiments in a small cylindrical tank filled with potassium chloride solution and samples of cucumber, noise was less than 1% with averaging, and acceptable images were produced at frequencies down to 1800 Hz. This suggests that EIT can be performed at low frequencies, which are likely to give larger signals during brain activity. Future work will include trials in humans and improvement of the current source and isolation.

Brain Chemistry↗