PubMed Health⌕ Search

Biomedical subjects

C A Monnig

Publications and source records attributed to C A Monnig.

7 recordsLinked to original sources

Determinants for substrate phosphorylation by p21-activated protein kinase (gamma-PAK).

gamma-PAK, originally designated PAK I and subsequently identified as a member of the p21-activated protein kinase family, has been shown to have cytostatic properties and to be involved in maintaining cells in a nondividing state [Rooney, R. D., et al., (1996) J. Biol. Chem. 271, 21498-21504]. The determinants for phosphorylation of substrates by gamma-PAK have been identified by examining the kinetics of phosphorylation of a series of synthetic peptides patterned after the sequence KKRKSGL, which is the site phosphorylated by gamma-PAK in the Rous sarcoma virus nucleocapsid protein NC in vivo and in vitro. With these peptides, the recognition sequence for gamma-PAK has been shown to contain two basic amino acids in the -2 and -3 positions, as represented by (K/R)RXS, in which the -2 position is an arginine, the -3 position is an arginine or a lysine, and X can be an acidic, basic, or neutral amino acid. A basic amino acid in the -1 or -4 position improves the rate of phosphorylation by increasing the Vmax and decreasing the Km. An acidic amino acid in the -1 position increases the rate (2.5-fold), as does an acidic residue in the -4 position, although to a lower extent (1.6-fold). Proline in the -1 or +1 position has a deleterious effect and inhibits phosphorylation by gamma-PAK. The substrate requirements of protein kinases that recognize basic amino acids on the N-terminal side of the phosphorylatable residue such as cAMP-dependent protein kinase (PKA) and Ca2+/phospholipid-dependent protein kinase (PKC) have been compared with gamma-PAK using the same peptides. An acidic residue in the -1 position negatively affects PKA and PKC; thus, peptides containing the sequence KRES can be used to identify gamma-PAK.

Amino Acid Sequence↗

Cleavage arrest of early frog embryos by the G protein-activated protein kinase PAK I.

PAK I is a member of the PAK (p21-activated protein kinase) family and is activated by Cdc42 (Jakobi, R., Chen, C.-J., Tuazon, P. T., and Traugh, J. A. (1996) J. Biol. Chem. 271, 6206-6211). To examine the effects of PAK I on cleavage arrest, subfemtomole amounts of endogenously active (58 kDa) and inactive (60 kDa) PAK I and a tryptic peptide (37 kDa) containing the active catalytic domain were injected into one blastomere of 2-cell frog embryos. Active PAK I resulted in cleavage arrest in the injected blastomere at mitotic metaphase, whereas the uninjected blastomere progressed through mid- to late cleavage. Injection of other protein kinases at similar concentrations had no effect on cleavage. Endogenous PAK I was highly active in frog oocytes, and antibody to PAK I reacted specifically with protein of 58-60 kDa. PAK I protein was decreased at 60 min post-fertilization, with little or no PAK I protein or activity detectable at 80 min post-fertilization or in 2-cell embryos. At the 4-cell stage PAK I protein increased, but the protein kinase was present primarily as an inactive form. Rac2 and Cdc42, but not Rac 1, were identified in oocytes and throughout early embryo development. Thus, PAK I appears to be a potent cytostatic protein kinase involved in maintaining cells in a non-dividing state. PAK I activity is high in oocytes and appears to be regulated by degradation/synthesis and through autophosphorylation via binding of Cdc42. PAK I may act through regulation of the stress-activated protein kinase signaling pathway and/or by direct regulation of multiple metabolic pathways.

Animals↗

Determination of retinoids by reversed-phase capillary liquid chromatography with amperometric electrochemical detection.

A method for separating and detecting retinoids by reversed-phase capillary liquid chromatography with amperometric electrochemical detection is described. Packed columns with an inner diameter of 180 microns were employed for the separation using C18 stationary phase and a mobile phase containing acetonitrile-water methanol (65:32.5:2.5, v/v/v) with 1% tetrabutylammonium perchlorate and 0.174 M acetate buffered at pH 5. The detection cell consisted of a carbon fiber barrel electrode held at 0.9 V versus an Ag/AgCl reference. Injection volumes of 2 microliters produced detection limits of 2.73, 0.472, 0.428, and 0.267 fmol (or 410, 64.1, 60.9, and 38.2 pg ml-1) for 13-cis-retinoic acid, all-trans-retinoic acid, retinaldehyde, and retinol, respectively. This represents an improvement in detection limits of at least three orders of magnitude for similar analyses using liquid chromatography and UV absorbance detection. The detector signal was linear over two orders of magnitude of analyte concentration. Retinoid concentrations in bovine serum were determined and found to be in good agreement with previously reported values.

Animals↗

Off-line coupling of capillary electrophoresis and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

An automated fraction collection interface is used in conjunction with matrix-assisted laser desorption/ionization (MALDI) time-of-flight mass spectrometry to analyze material isolated by capillary electrophoresis (CE). CE fractions are deposited directly on the MALDI probes so that individual peaks from the electropherogram are associated with a single sample spot on the probe. MALDI matrices with high acid concentrations afford enhanced tolerance of electrophoresis buffers. The utility of this hybrid instrument is demonstrated by separation and mass analysis of a tryptic digest of cytochrome c and synthetic mixtures of four proteins. Mass assignments corresponding to the protonated molecular ions are in good agreement with those predicted from molecular structure. Miniaturization of the interface affords enhanced sensitivity, with good-quality spectra from separations of as little as 25 fmol of protein.

Amino Acid Sequence↗

On-column sample gating for high-speed capillary zone electrophoresis.

High-speed zone electrophoresis in a fused-silica capillary is described. Elevated electric fields and short capillary lengths allow a mixture of fluorescein isothiocyanate (FITC) labeled amino acids to be separated in times as short as 1.5 s. Formation of the analyte zone at the head of the capillary is controlled by laser-induced photolysis of a tagging reagent. This gating procedure allows rapid and automated introduction of sample into the capillary. Ultimately, Joule heating of the buffer limits the speed and efficiency of the separation.

Automation↗

Sample gating in open tubular and packed capillaries for high-speed liquid chromatography.

A new liquid chromatography instrument is described that employs small-diameter capillary columns and an optically controlled sample gating procedure to separate a mixture of fluorescein isothiocyanate (FITC) labeled amines in as few as 6 s. Efficiency of the separation, expressed as the number of theoretical plates, is observed to increase linearly with column length and thus analysis time. The combination of short analysis time and automated sample introduction allows signal averaging to be used to enhance the precision of the measurement.

Automation↗