The effect of prophylactic epsilon-aminocaproic acid on bleeding, transfusions, platelet function, and fibrinolysis during coronary artery bypass grafting.

BACKGROUND: Antifibrinolytic medications administered before skin incision decrease bleeding after cardiac surgery. Numerous case reports indicate thrombus formation with administration of epsilon-aminocaproic acid (epsilon-ACA). The purpose of this study was to examine the efficacy of epsilon-ACA administered after heparinization but before cardiopulmonary bypass in reducing bleeding and transfusion requirements after primary coronary artery bypass surgery. METHODS: Seventy-four adult patients undergoing primary coronary artery bypass surgery were randomized to receive 125 mg/kg epsilon-ACA followed by an infusion of 12.5 mg x kg(-1) x h(-1) or an equivalent volume of saline. Coagulation studies, thromboelastography, and platelet aggregation tests were performed preoperatively, after bypass, and on the first postoperative day. Mediastinal drainage was recorded during the 24 h after surgery. Homologous blood transfusion triggers were predefined and transfusion amounts were recorded. RESULTS: One patient was excluded for surgical bleeding and five patients were excluded for transfusion against predefined criteria One patient died from a dysrhythmia 2 h postoperatively. Among the remaining 67, the epsilon-ACA group had less mediastinal blood loss during the 24 h after surgery, 529+/-241 ml versus 691+/-286 ml (mean +/- SD), P < 0.05, despite longer cardiopulmonary bypass times and lower platelet counts, P < 0.05. Platelet aggregation was reduced in both groups following cardiopulmonary bypass but did not differ between groups. Homologous blood transfusion was similar between both groups. CONCLUSIONS: Prophylactic administration of epsilon-ACA after heparinization but before cardiopulmonary bypass is of minimal benefit for reducing blood loss postoperatively in patients undergoing primary coronary artery bypass grafting.

Adult↗

Assessment of left ventricular function and hemodynamics with transesophageal echocardiography.

Transesophageal echocardiography (TEE) plays an important role in the evaluation of left ventricular function and hemodynamics in the critical care setting. The technique provides immediate data regarding regional myocardial ischemia, global ventricular function, volume, and the presence of cardiac tamponade. This article outlines the role of TEE in the evaluation of left ventricular function in the intensive care unit and presents practical information for the use of TEE in evaluating systolic function, diastolic function, and cardiac tamponade.

Cardiac Output↗

Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography.

BACKGROUND: Cannulation of the internal jugular vein (IJV) is associated with a 95% success rate when external landmarks are used. Anatomic variability has been implicated as the cause for difficulty in cannulation without ultrasound. In contrast to an IJV located lateral to the carotid artery (CA), an IJV overlying the CA may result in CA puncture. The authors' purpose in this study was to examine, using ultrasound, the anatomic relation of the IJV and CA as viewed from the perspective of a cannulating needle. METHODS: Ultrasound imaging was used in 1,136 patients to examine the relation between the IJV and CA. A 7.5-MHz transducer was placed in the direction of a cannulating needle on the right neck at the apex of the angle formed by the division of the sternocleidomastoid muscle. A Polaroid photograph of the image was later scored by three blinded investigators according to the percentage of the CA overlaid by the IJV (0 to 4). RESULTS: Of the 1,136 Polaroid photographs of the ultrasound images, 1,009 were suitable for scoring. Fifty-four percent of all patients received a score of 4, which indicated that the IJV overlies more than 75% of the CA in an imaging plane positioned in the direction of a cannulating needle. Patients older than 60 yr were more likely to have this anatomy than patients younger than 60 yr (P < 0.05). None of the other patient characteristics recorded were predictive of this anatomic relation. CONCLUSIONS: In a majority of patients, the IJV is not lateral to the CA in an ultrasound imaging plane positioned in the direction of a cannulating needle. Instead, the IJV overlies the CA in 54% of patients overall, predisposing these patients to CA puncture if the cannulating needle traverses the IJV.

Adult↗

Measurement of pulmonary blood flow with transesophageal two-dimensional and Doppler echocardiography.

Transesophageal echocardiography permits measurement of the pulmonary artery diameter (two-dimensional echocardiography) and pulmonary artery blood flow velocity (pulsed-wave Doppler). These measurements considered with the heart rate allow for the determination of pulmonary artery blood flow, which is equivalent to cardiac output. This study compared the precision of transesophageal Doppler-derived cardiac output (DdCO) with the precision of thermodilution cardiac output (TdCO) and examined the agreement between DdCO and TdCO in 33 cardiac surgical patients. The proximal pulmonary artery diameter was measured in triplicate during systole and end expiration, and the local blood flow velocity was recorded on video tape. The instantaneous pulmonary artery blood flow velocity (centimeters per second) for three random cardiac beats was integrated with respect to time. DdCO was calculated as the product of the flow velocity integral (centimeters per beat), heart rate (beats per min), and the mean cross-sectional area (centimeters squared) of the main pulmonary artery. At the same time that the velocity recordings were made, three serial determinations of TdCO were made by an independent observer. Pulmonary blood flow could be measured in 25 of the 33 patients. The anatomical relationship among the esophagus, the left main stem bronchus, and the pulmonary artery did not allow adequate imaging of the pulmonary artery in 8 (24%) of the patients. A total of 45 sets of triplicate measurements were made. The range of cardiac outputs encountered was 1.7-6.6 l.min-1 by TdCO and 1.5-6.9 l.min-1 by DdCO. The 95% confidence limits for the difference between the two methods (agreement) was 0.030 +/- 0.987 l.min-1.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗