PubMed Health⌕ Search

Biomedical subjects

C A Wheeler-Kingshott

Publications and source records attributed to C A Wheeler-Kingshott.

4 recordsLinked to original sources

Investigation of MS normal-appearing brain using diffusion tensor MRI with clinical correlations.

OBJECTIVE: To quantitatively investigate water diffusion changes in normal-appearing white matter (NAWM) and gray matter in patients with MS, and to evaluate whether these changes are correlated with clinical disability and disease duration. BACKGROUND: Diffusion tensor imaging provides quantitative information about the magnitude and directionality (anisotropy) of water diffusion in vivo and detects pathologic changes in MS brain tissue. METHODS: Diffusion tensor imaging was performed in 39 patients with MS and in 21 age-matched control subjects. Quantitative indices, including fractional anisotropy, volume ratio, and mean diffusivity, were obtained in 30 regions of interest located in normal-appearing basal ganglia, cerebellar gray matter, and supratentorial and infratentorial NAWM. RESULTS: Patients with MS showed significantly reduced anisotropy and a trend toward increased diffusivity in the infratentorial and supratentorial NAWM, and significantly increased anisotropy in the basal ganglia. In all patients with MS, both fractional anisotropy and mean diffusivity in the cerebral peduncles were inversely correlated with the Expanded Disability Status Scale and pyramidal functional scores. In patients with relapsing-remitting MS, there was a strong correlation between Expanded Disability Status Scale score and fractional anisotropy in both supratentorial and infratentorial NAWM. In primary and secondary progressive MS, disease duration correlated strongly with mean diffusivity in infratentorial NAWM and fractional anisotropy in the cerebral peduncles, respectively. CONCLUSION: The most striking finding of decreased fractional anisotropy in supratentorial and infratentorial NAWM and increased fractional anisotropy in basal ganglia may result from axonal degeneration due to fiber transection in remote focal lesions. Diffusion tensor imaging indices, in particular fractional anisotropy, appear sensitive to structural damage in NAWM that is associated with disability and progression in MS.

Adult↗

Burst excitation for quantitative diffusion imaging with multiple b-values.

A quantitative imaging sequence has been developed to exploit the intrinsic sensitivity of Burst NMR data to molecular diffusion. In the scan time of a single spin echo experiment, it is possible to acquire many images of the same slice, with a different T(2) and diffusion weighting. Under favorable conditions, it is possible to obtain both the diffusion coefficient and T(2) from the same experiment; or, by correcting for T(2) relaxation using a control image, more precise diffusion coefficients may be measured. The quantitative values in rat brain are in agreement with those from conventional experiments. The major gains of this method are the potentially reduced scan time, the higher number of acquired images corresponding to different diffusion weightings, the reduced sensitivity to inter-scan motion artifact and to local variations in magnetic susceptibility, and an automatic co-registration between T(2) and diffusion images. Problems with the sequence include a lower signal-to-noise ratio than is achievable with diffusion-weighted spin-echo imaging, the limitation of measuring only in-plane components of diffusion and, at present, single-slice acquisition.

Animals↗

Burst imaging: rotation artifacts and how to correct them.

The effect of coherent rotational motion on images acquired with the ultrafast single-shot spin-echo Burst sequence has been analyzed. Previous experience has demonstrated that sample rotation during Burst experiments has the potential to cause severe image artifacts. In this paper we show that no distortions are visible when the readout gradient is parallel to the rotation axis, but that there is a very distinctive behavior for the case of the rotation axis orthogonal to the imaging plane. The mathematical expression that describes the resulting signal is presented and is used as a basis for a method of correcting the k-space data. The conditions under which undistorted images may be recovered are discussed. It is shown that there is an asymmetry, dependent on the rotation direction, in both the manifestation of the artifact and the range of angular velocities over which one can correct the images. Data from an agar gel phantom rotating at a known rate are used to show how the theory is successful at reconstructing images, with no free parameters. The range of angular velocities over which correction is possible depends on the timing parameters of the pulse sequence, but for these data was -0.016 < omega less, similar 0.1 revolutions/s. Volunteer experiments have confirmed that the theory is applicable to patient motion and can correct motional distortion even when the exact rate is not known a priori. By optimizing the reconstruction to restore a known sample geometry/aspect ratio, an estimate of the rotation angular frequency is obtained with a precision of +/-10%.

Artifacts↗

STEAM-Burst: a single-shot, multi-slice imaging sequence without rapid gradient switching.

The stimulated-echo acquisition mode-Burst sequence is a single-shot, multi-slice imaging technique that does not involve rapid gradient switching. A Burst excitation pulse train is followed by a 90 degrees hard pulse and, after a mixing time, by a 90 degrees slice-selective pulse. A read gradient refocuses a set of stimulated echoes, which can be phase-encoded to form an image. By repeating the selective pulse N times, each time with the carrier frequency offset differently, it is possible to sample N slices in a single-shot. A comparison is made of the sequence with other three-dimensional single-shot methods. Experiments implementing the technique on a 3 T whole-body imaging system and a 2 T, 31-cm bore animal imager are described. Both phantom and brain images are presented. The principal advantages of the new sequence are its speed, the absence of rapid gradient switching and corresponding freedom from artifacts, its insensitivity to static magnetic field inhomogeneities, and its low acoustic noise. The main disadvantages are the low signal-to-noise ratio of the images produced and the concomitant limitation in resolution.

Animals↗