PubMed Health⌕ Search

Biomedical subjects

C A Zimmer

Publications and source records attributed to C A Zimmer.

9 recordsLinked to original sources

Influence of surgeon's tying technique on knot security.

The purpose of this study was to determine the influence of the surgeon's tying technique on knot security using 0 and 2-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by surgeons. The surgeon's faulty technique can easily be corrected by didactic information and psychomotor skill training.

Clinical Competence↗

A new compound-curved needle for microvascular surgery.

A new compound-curved needle has been designed and developed for microvascular surgery from a unique stainless steel alloy, American Society for Testing Materials 45500. This needle has two distinct radii of curvature and a short tapered point, followed by a curved distal section. Despite its geometry, it exhibits similar resistance to bending and breakage as a curved needle with a single radius of curvature manufactured from the same alloy. The design of this new needle enables plastic surgeons to pass it through vessel walls with greater accuracy to a controlled depth and length of bite than a curved needle with a single radius of curvature.

Humans↗

Biochemical performance of tapercut cardiovascular needles.

Standardized reproducible tests have been developed to determine the biomechanical performance of cardiovascular needles. The parameters used to assess performance were: 1) sharpness, 2) resistance to bending, and 3) ductility. Four comparable groups of tapercut and taper point cardiovascular needles were selected from different manufacturers for these biochemical studies. The results of this testing demonstrated that needle geometry, needle composition, and the manufacturer were important determinants of needle performance. When comparable needles were evaluated, the biochemical performance of cardiovascular needles manufactured by Ethicon, Inc. (Somerville, NJ) were superior to needles produced by other manufacturers. The superior performance characteristics of the cardiovascular needles produced by Ethicon, Inc. were related to their unique stainless steel alloy, American Society for Testing Materials 45500, which has greater yield and tensile strengths than the alloy used by the other manufacturers. This stainless steel alloy was ideal for the production of tapercut needles, which combined some of the features of a reverse cutting edge needle and taper point needle. Its very short cutting edges allowed it to penetrate the membrane at considerably lower penetration forces than were encountered with comparable taper point needles. In addition, the investigation indicated that the trocar point cardiovascular needles produced a large triangular defect whose diameter was much larger than that of the needle body. For this reason, the use of the trochar point needle is not recommended in cardiovascular surgery.

Biomechanical Phenomena↗

Influence of knot configuration and tying technique on the mechanical performance of sutures.

The purpose of this investigation was to determine the influence of knot configuration and tying technique on the mechanical performance of surgical sutures. Multifilament and monofilament nylon sutures were selected for this evaluation because they are commonly used in wound closure. The mechanical performance of these sutures was judged by the following parameters: knot breakage force, configuration of secure knots, and knot run down force. During each test, tension was applied at either rapid or slow rates, which correlates with the physician's speed of tying knots. On the basis of these mechanical performance tests, four throw square (1 = 1 = 1 =1) knots and five throw square (1 = 1 = 1 = 1 = 1) knots are recommended for monofilament nylon and multifilament nylon sutures, respectively, in which the speed of application of forces to the knots is relatively slow. Because these tests can easily be replicated in any laboratory, manufacturers now have a scientific basis for recommending specific tying techniques for their surgical sutures.

Physical Phenomena↗

Damage to tissue defenses by EMLA cream.

EMLA is a new topical agent that safely anesthetizes intact skin. The purpose of this study was to determine if this cream could be safely used for anesthetizing wounds. This investigation evaluated the potential toxicity of EMLA cream in wounds by measuring its effect on host defenses and on the biology of wound repair. In contaminated wounds, EMLA cream elicited an exaggerated inflammatory response that damaged host defenses, inviting the development of infection. As a result of these investigations, we do not recommend the use of EMLA cream in wounds.

Anesthetics, Local↗

Concurrence of multiple sclerosis and Hodgkin's disease.

Although multiple sclerosis and Hodgkin's disease are reported to have similar epidemiologic features, this is only the first case report in which there was concurrence of these diseases. Fourteen years after successful treatment of Hodgkin's disease, this 31-year-old white male developed multiple sclerosis. The diagnosis of multiple sclerosis was made on the basis of clinical and paraclinical findings that were characteristic of multiple sclerosis. In addition, specific tests were performed to rule out a variety of infectious, metabolic, and neoplastic diseases that simulate multiple sclerosis.

Adult↗

Influence of emergency physician's tying technique on knot security.

The purpose of this study was to determine the influence of emergency physician's tying technique on knot security using 2-0 and 4-0 monofilament and multifilament nylon sutures. Using an Instron Tensile Tester and a portable tensiometer, knot security was achieved with these sutures using four-throw square knots (1 = 1 = 1 = 1). After didactic and psychomotor skill training, medical students were taught to construct the four-throw square knot using either a two-hand tie or an instrument tie. Using the portable tensiometer, their knot tying techniques were judged to be superior to those used by emergency physicians. The emergency physician's faulty technique can easily be corrected by didactic information and psychomotor skill training.

Emergency Medicine↗

Adaptive communication systems for patients with mobility disorders.

An adaptive communication system has been developed for individuals with mobility disorders. It uses specialized computer software and hardware that compensate for this disability. For an individual with a motor-control impairment who is not able to use a keyboard effectively, a computer voice-recognition technology now removes this communication barrier. Speech-recognition systems consist of three basic components: speech processing, speech recognition, and speech understanding. The new Dragon Dictate (Dragon Systems, Inc., Newton, Mass.) is the first large-vocabulary speech recognition system in the personal computer industry that interactively learns a user's vocabulary and mode of speaking and responds to natural language rather than to limited sets of words. This speech-recognition system requires a microprocessor, a display monitor, a printer, and specific software packages, including word-processing and enhanced memory-management software. Important considerations in the use of this speech-recognition system include microphone positioning and training of the system. With the advent of this new voice-recognition computer system, another communication barrier between the disabled and society has been overcome.

Communication Devices for People with Disabilities↗

Computer analysis of the performance of the BTE Work Simulator.

The BTE Work Simulator (Baltimore, Therapeutic Equipment Co., Hanover, Md.) recreates the work environment by providing a rotatable shaft to which a variety of tools can be attached. The patient can simulate the coordinated muscle and joint movements involved in the work situation, exercising either isometrically or isotonically, and thereby increase the potential for return to work. The BTE Work Simulator has four major components: the exercise head to provide variable resistance, tools that attach to the exercise head, a control console containing a microprocessor that calculates work and power, and the Quest software package (Baltimore Therapeutic Equipment Co.). Quest provides four static/isometric and seven dynamic/isotonic tests that can be used to document the extent of a patient's impairment. In addition, it has daily treatment options and acts as an extensive data base capable of retrieving any stored test or treatment results. This software system greatly facilitates the use of the BTE Work Simulator by providing instant calculations of power and coefficients of variation, immediate patient feedback, graphic expansion of the data, and printed evaluation reports.

Computer Simulation↗