[Value of x-ray computed tomography in the evaluation of the extensiveness and the therapeutic strategy for bladder cancer].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C Abbou.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A law issued on december 22, 1976 and aimed at increasing the number of kidney transplantations in France authorizes the removal of kidneys from deceased persons of full age provided they had not expressed refusal while still alive; for decreased persons under age, removal is subject to written consent of the legal representative. In a general teaching hospital of whose than 1 000 beds, 21 kidneys donors were operated upon between January 1, 1971 and December 31, 1975 (an average of 4.2 per year). A kidney transplantation team was developed in 1976. Between January 1, 1976 and August 31, 1979, 83 kidneys donors were operated, an average of 22.6 per year. Ninety-five per cent (59/62) of the kidneys removed and transplanted in the hospital began to function (diuresis greater than 2 ml/min) within minutes of releasing the clamp, no matter how long cold ischaemia had lasted. The increase in kidney removal and transplantation may be attributed to the fact that motivation was maintained among the various units concerned (anaesthesia and intensive care, neurosurgery, neuroradiology) by sustained information and teaching.
A patient with severe acute pyonephritis and septicaemia had persistent symptoms of infection despite appropriate chemotherapy. Although no obstruction was seen on ascending ureteropyelography, exploratory lumbar incision was considered. However, computerized tomography (CT scan) failed to show any obstacle or collection of pus but indicated diffuse infection of kidney. Medical treatment was continued and the patient recovered. This case and a review of the literature has prompted the authors to compare CT scan with conventional contrast-radiography methods in septicaemias of renal origin. It appeared that intravenous and ascending uretero-pyelography are often at fault, and the latter is known to carry iatrogenic risks. CT scan is of considerable help when looking for foci of infection and is proposed as a deciding examination in septicaemias with or without signs suggestive of renal lesions.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The CT scan is of diagnostic value in cases of renal cancer extension. Details concerning 23 cases of renal tumours are described, 13 of these patients having venous invasion from the cancer, confirmed by operation. Computed tomography, is therefore of primordial value for the diagnosis of the degree of renal cancer spread.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In radiation therapy of tumors, several techniques are used to prevent injury of the intestinal loops. Their purpose is to drive the intestine out of the external beam. Understanding the disadvantages they present, a temporary prosthesis which effectively protects the small bowel, and is easy to remove, has been developed. The device is a 600 to 1,000 ml, silicone rubber, expandable balloon. When implanted in the pelvis or retroperitoneal cavity, and filled, this balloon displaces the intestinal loops out of the pelvic irradiation field. It may remain either filled or empty between each irradiation session. Due to its particular elliptical shape, once empty, the balloon can be removed through a 3 cm incision under local or peridural anesthesia at the completion of radiotherapy. Eleven patients with recurrent (8) or primary (3) cancer have been implanted. The protective effect has been evaluated on successive biologic tests, performed during treatment. No problem related to the prosthesis, no alteration of the biologic tests, nor bowel injury have been observed after several months follow-up. This device is suitable for preventing intestinal complications during therapy, allowing a higher dose of radiations in some cases.