Reentry site during fibrillation induction in relation to defibrillation efficacy for different shock waveforms.

INTRODUCTION: Unsuccessful defibrillation shocks may reinitiate fibrillation by causing postshock reentry. METHODS AND RESULTS: To better understand why some waveforms are more efficacious for defibrillation, reentry was induced in six dogs with 1-, 2-, 4-, 8-, and 16-msec monophasic and 1/1- (both phases 1 msec) 2/2-, 4/4-, and 8/8-msec biphasic shocks. Reentry was initiated by 141+/-15 V shocks delivered from a defibrillator with a 150-microF capacitance during the vulnerable period of paced rhythm (183+/-12 msec after the last pacing stimulus). The shock potential gradient field was orthogonal to the dispersion of refractoriness. Activation was mapped with 121 electrodes covering 4 x 4 cm of the right ventricular epicardium, and potential gradient and degree of recovery of excitability were estimated at the sites of reentry. Defibrillation thresholds (DFTs) were estimated by an up-down protocol for the same nine waveforms in eight dogs internally and in nine other dogs externally. DFT voltages for the different waveforms were positively correlated with the magnitude of shock potential gradient and negatively correlated with the recovery interval at the site at which reentry was induced by the waveform during paced rhythm for both internal (DFT = 1719 + 64.5VV - 11.1RI; R2 = 0.93) and external defibrillation (DFT = 3445 + 150VV - 22RI; R2 = 0.93). CONCLUSION: The defibrillation waveforms with the lowest DFTs were those that induced reentry at sites of low shock potential gradient, indicating efficacious stimulation of myocardium. Additionally, the site of reentry induced by waveforms with the lowest DFTs was in myocardium that was more highly recovered just before the shock, perhaps because this high degree of recovery seldom occurs during defibrillation due to the rapid activation rate during fibrillation.

Animals↗

The mid-term results of ventricular containment (ACORN WRAP) for end-stage ischemic cardiomyopathy.

The acorn cardiac support device (ACSD) is a device designed to treat heart failure by containing the heart to prevent further dilation. Six patients with symptomatic heart failure due to ischemic cardiomyopathy were treated surgically with ACSD. All patients simultaneously underwent coronary artery bypass grafting. Ventricular reconstruction was also performed in 5 of the 6 patients. We followed up the patients for 12 months postoperatively, monitoring the left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), mitral regurgitation, and NYHA classification. Both the LVEDD and LVESD were significantly improved one month postoperatively (from 63.2 to 50.6 mm, p=0.004, and from 51.6 to 39.5 mm, p=0.025, respectively). These dimensions did not change significantly over the next 11 months. NYHA functional class improved significantly from a mean of 3 to 1.4 at 12 months (p=0.012). Mitral regurgitation improved from a mean of 2.7 preoperatively to 1.4 at 12 months and the average LVEF also improved from 27% preoperatively to 35.9% at 12 months after surgery. However these latter two results were not statistically significant. There were no late deaths and no readmissions for heart failure. Repeat coronary angiography at 6 months revealed patent grafts in all patients. The mid-term results of ACSD for patients with symptomatic heart failure suggest that ventricular containment may be useful for preventing further cardiac dilation in patients with ischemic cardiomyopathy. Randomized, long-term studies are needed to assess the efficacy and possible role of ASCD in the future management of heart failure.

Aged↗

Passive epicardial containment prevents ventricular remodeling in heart failure.

BACKGROUND: We examined the effects of passive containment of the cardiac ventricles with a surgically placed epicardial prosthetic wrap on indexes of left ventricular (LV) remodeling in dogs with heart failure. METHODS: Heart failure (LV ejection fraction 30% to 40%) was produced in 12 dogs by intracoronary microembolization. Six dogs underwent mid-sternotomy and pericardiotomy with placement of a preformed-knitted polyester device (Acorn Cardiac Support Device [CSD], Acorn Cardiovascular, Inc, St. Paul, MN) snugly around the ventricles and anchored to the atrioventricular groove. Six dogs did not undergo surgery and served as controls. Dogs were followed for 3 months prior to sacrifice. RESULTS: In controls, LV end-diastolic volume increased after 3 months (67 +/- 12 versus 83 +/- 8 ml; p = 0.04), while in CSD-treated dogs, it decreased (68 +/- 10 versus 61 +/- 10 ml; p = 0.002). CSD-containment of LV size was associated with increased LV systolic fractional area of shortening, while in controls, fractional area of shortening decreased. CSD-treated dogs also showed amelioration of myocyte hypertrophy and attenuation of interstitial fibrosis compared to controls. CONCLUSIONS: In dogs with heart failure, passive epicardial containment of the ventricles with the Acorn CSD ameliorates LV remodeling and improves LV systolic function.

Animals↗

Ventricular containment as an adjunctive procedure in ischemic caridomyopathy: early results.

BACKGROUND: Ventricular containment with custom-made polyester mesh is an evolving technique that has been studied in experimental animals with heart failure with good results. METHODS: Five patients with symptomatic heart failure and ischemic cardiomyopathy were enrolled in a Phase I study, and underwent ventricular containment with custom-made polyester mesh along with coronary artery bypass grafting. Four patients had additional ventricular reconstruction of large myocardial scars. RESULTS: All patients were in NYHA functional class III at the time of their operation with a mean ejection fraction of 27.4%+/-6.6%. There were no deaths. Mean postoperative ejection fraction was 35.1%+/-12.6% (p = 0.16). Left ventricular end-diastolic diameter fell from 63.2+/-1.6 mm preoperatively to 50.6+/-5 mm, postoperatively (p = 0.004). There was no evidence of diastolic dysfunction or pericardial constriction on intra- or postoperative echocardiography. At a mean follow-up of 180 days all patients were in NYHA class I with no readmissions for heart failure. Repeat coronary angiography at 6 months revealed patent grafts in all patients. CONCLUSIONS: Ventricular containment with a customized mesh may be performed safely as an adjunct to conventional cardiac operation in patients with symptomatic heart failure. Longer follow-up with an expansion of the study will help delineate the long-term effects of this therapy.

Cardiac Surgical Procedures↗

Strength-interval curves in canine myocardium at very short cycle lengths.

While ventricular electrophysiological properties have been intensively studied at normal heart rates, little is known about these properties at the very short cycle lengths (approximately 100 msec), which are present in ventricular fibrillation. We examined refractoriness in the right ventricles of six dogs at stimulation intervals of 80 to 300 msec. Starting at 300 msec, the basic (S1) cycle length was decremented by 10 msec each beat to 200, 150, or 125 msec. A 1-msec premature (S2) stimulus of 1, 5, 10, or 20 mA was then introduced. The S1-S2 interval was decremented until capture was lost. The refractory period was considered to be the shortest interval that captured the heart for each S2 strength. Only pacing episodes that did not induce fibrillation were included. Strength-interval curves maintained the same hyperbolic shape but shifted to very short refractory periods as the S1-S1 interval was decreased. At the shortest S1-S1 intervals, premature stimuli were capable of capturing the heart without inducing ventricular fibrillation for S1-S2 intervals as short as 83 +/- 3 msec. Thus, decremental rapid pacing can produce refractory periods shorter than the cycle length during ventricular fibrillation. This finding suggests that there is no need to postulate a discontinuous jump to new electrophysiological properties or relationships at the onset of fibrillation, but that the capability for fibrillation is an integral part of normal electrophysiological parameters when they are pushed to values that do not occur normally. The results of this study should be useful in the further development of active membrane models and cellular automata models of cellular electrical behavior.

Animals↗

Lead systems for atrial defibrillation.

In summary, these five studies show that electrode locations that include both left and right atrium result in lower thresholds. Thresholds from right atrium to chest wall patch are higher than thresholds from right atrium to cardiac vein, suggesting that confinement of the electric field by a transvenous electrode system is advantageous. Of the transvenous locations tested, the right atrial appendage to left atrial appendage defibrillation vector consistently had the lowest defibrillation energy threshold. The proximal coronary sinus to right atrial vector may be inappropriate due to the high thresholds observed. The large variability of the mean threshold for the obtuse marginal location in the cardiac vein vasculature suggests that this vector may result in higher thresholds in some instances. Electrode locations that have high defibrillation thresholds and are in close proximity to the sinoatrial or atrioventricular node increase the likelihood of sinus arrhythmias or conduction block following the defibrillation shocks. No difference was detected between the thresholds between the single catheter, two electrode system and the two catheter system, despite the variability of location of the electrode in the right atrium, suggesting that such a catheter may provide a simpler implantation procedure and equivalent thresholds in some patients. These findings suggest that coronary sinus/great cardiac vein catheter designs should strive for implantation in the distal portion of the great cardiac vein so that the shocking electrode underlies the left atrium with the other shocking electrode located in the right atrium.

Animals↗

Some factors affecting bubble formation with catheter-mediated defibrillator pulses.

Factors affecting bubble formation during delivery of defibrillator pulses to arrhythmogenic cardiac tissue via a catheter are unknown. We investigated the role of energy, electrode surface area, interelectrode distance, and electrode polarity on bubble formation and on current and voltage waveforms during delivery of damped sinusoidal discharges from a standard defibrillator to anticoagulated bovine blood. Gas composition was studied with mass spectrometry. Defibrillator energy settings were varied between 5 and 360 J. The principal catheter used for study was a Medtronic 6992A lead. Additional electrodes tested included 2, 5, and 10 mm long No. 6F, 7F, and 8F copper electrodes. Interelectrode distances used to assess the effect of anode-cathode spacing were 1, 5, 10, and 20 cm. Bubble volume increased linearly from 0.043 to 0.134 ml per cathodal pulse and from 0.030 to 3.50 ml per anodal pulse as energy settings were increased from 5 to 360 J (r = .99). Typical smooth waveforms for both current and voltage were seen only in the absence of bubbles. The voltage waveform was distorted for each cathodal pulse of 100 J or more and for each anodal pulse of 10 J or more only if bubbles were present. The effect of electrode surface area on bubble formation was tested at a 200 J energy setting and at a 10 cm interelectrode distance with the use of cathodal pulses. Bubble formation varied inversely with electrode surface area (r = .876). Bubble formation, however, varied minimally as interelectrode spacing was changed from 1 to 20 cm. The effect of polarity on bubble formation when the Medtronic 6992A distal electrode and an 8.5 cm disk electrode separated by 10 cm were used was highly significant. For a 200 J pulse, bubble formation with the catheter as anode was 3.30 +/- 0.10 ml and with the catheter as cathode it was 0.070 +/- 0.002 ml (p less than .001). Mass spectrometry of both anodal and cathodal gas samples demonstrated the constituents of the gas bubble to include a variety of gases, which is inconsistent with simple electrolytic production of the bubbles observed. The predominance of nitrogen in either polarity sample suggested that the principal source of the bubble was dissolved air. In summary, bubble formation at an electrode receiving damped sinusoidal outputs from a standard defibrillator does not vary significantly with varying interelectrode distance. However, it is directly proportional to energy and inversely proportional to electrode surface area. Anodal catheter discharges produce considerably more bubbles than do cathodal discharges.(ABSTRACT TRUNCATED AT 400 WORDS)

Catheterization↗

Mechanical "cough" cardiopulmonary resuscitation during cardiac arrest in dogs.

Hemodynamic findings during ventricular fibrillation (VF) and closed-chest cardiopulmonary resuscitation (CPR) are similar to those described during VF and vigorous coughing. Interventions during CPR that mimic the physiologic events of coughing (high intrathoracic pressure and high intraabdominal pressure) improve perfusion during VF and CPR. An external circulatory assist apparatus was devised to emulate cough physiology, i.e., simultaneous pulsatile increases in intrathoracic pressure (pneumatic vest), intraabdominal pressure (abdominal binder) and airway pressure (high-pressure airway inflation). In this study, vest/binder CPR was compared with conventional CPR during 30 minutes of VF and artificial support in 18 randomized dogs. Defibrillation and long-term (more than 24 hours) survival were chosen as end points. During VF and artificial support, aortic and right atrial (RA) pressures, the instantaneous aortic-RA pressure difference (coronary perfusion pressure) and blood gas levels were measured. After 30 minutes of VF and administration of 1 mg of epinephrine, countershock was attempted. Systolic aortic and RA pressures, mean aortic-RA pressure difference and blood gas levels were not significantly different between dogs that were successfully resuscitated and those that were not. However, peak diastolic coronary perfusion pressure (peak diastolic aortic-RA pressure) for survivors averaged 23 +/- 6 mm Hg, but only 6 +/- 10 mm Hg for nonsurvivors (p less than 0.001). A peak diastolic coronary perfusion pressure 16 mm Hg or greater had a positive and negative predictive value for a successful outcome of 1.00. Only 1 of 9 conventional CPR dogs survived 24 hours; 7 of 9 dogs supported with the vest/binder device were alive and neurologically normal at 24 hours (p = 0.007).(ABSTRACT TRUNCATED AT 250 WORDS)

Abdomen↗

Predictive indices of successful cardiac resuscitation after prolonged arrest and experimental cardiopulmonary resuscitation.

To determine if clinically accessible hemodynamic and blood gas measurements are of value in predicting outcome of countershock after prolonged ventricular fibrillation (VF) and artificial cardiopulmonary support, 14 dogs were studied during 30 minutes of VF using two randomly assigned closed-chest techniques. Seven dogs underwent conventional CPR; the other seven were supported with a pneumatic thoracic vest and abdominal binder, which were inflated synchronously with the airway. Ascending aortic (Ao), right atrial (RA), and instantaneous coronary perfusion pressures (Ao - RA) were measured at five-minute intervals. Ao and RA blood samples were analyzed at 10, 20, 25 and 30 minutes for PO2, PCO2, and pH. After 25 minutes, 1 mg epinephrine was given intravenously, and five minutes later defibrillation was attempted. If unsuccessful, repeated countershocks, conventional pharmacologic therapy, and artificial support were continued. If a perfusing spontaneous cardiac rhythm did not result within an additional 30 minutes, the experiment was terminated. Six animals developed a perfusing cardiac rhythm after one or more countershocks (Group 1); eight failed to develop a perfusing rhythm after repeated countershocks and an additional 30 minutes of resuscitative effort (Group 2). Five Group 1 dogs received vest/binder artificial support. When measured values were averaged over the study period, Group 1 was found to have a significantly greater Ao end-diastolic pressure (AoEDP) and peak diastolic coronary perfusion pressure (CPP) when compared to Group 2 (23 +/- 6 vs 14 +/- 8 mm Hg, P less than .05; and 22 +/- 6 vs 5 +/- 10 mm Hg, P less than .01, respectively).(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Catheter-mediated electrical ablation of the posterior septum via the coronary sinus: electrophysiologic and histologic observations in dogs.

In a series of 12 dogs, the electrophysiologic and histologic effects of a single damped sine-wave shock delivered via standard electrocatheters to the region of the coronary sinus orifice were investigated. Six dogs received 200 J and six received 360 J of stored energy. The shock was delivered to two consecutive proximal poles of a standard quadripolar catheter positioned at the coronary sinus orifice and connected to the positive output (anode) of a defibrillator. A disc electrode positioned on the anterior chest wall served as the cathode (negative pole). During the shock, voltage and current were recorded. Electrophysiologic testing was done before and 4 weeks after the shock. At 4 weeks, animals were killed and serial sections of the atrioventricular groove and conduction system were performed. No significant long-term change in atrioventricular conduction, spontaneous or induced atrial or ventricular arrhythmias was observed. However, transient atrioventricular block was seen in five and idioventricular rhythms in six animals in the short term. No persistent electrocardiographic changes were observed, and no sudden deaths occurred. Microscopically, transmural injury at the anulus proper or basilar ventricular epicardium was inconstant and infrequent. However, transmural atrial injury at the level of the coronary sinus was produced over a 10 +/- 5 mm length with the 200 J shock and a 21 +/- 6 mm length with the 360 J shock. Neither coronary artery injury nor damage to the conduction system was seen and cardiac tamponade did not occur. However, localized intramural atrial rupture of the coronary sinus wall (on the endocardial aspect only) was observed in each dog, consistent with barotrauma. With the present technique, atrial injury potentially capable of blocking the effects of accessory pathway conduction could be produced without other electrophysiologic alterations or complications. Injury to the anulus proper (and therefore to any accessory pathway per se) is probably unlikely. Barotrauma may play a significant role in the type of injury observed in this study.

Animals↗

Acute ventricular reduction with the acorn cardiac support device: effect on progressive left ventricular dysfunction and dilation in dogs with chronic heart failure.

BACKGROUND AND AIM: Surgical resection of myocardium that acutely reduces left ventricular (LV) volume in patients with advanced heart failure (HF), the so-called "Batista Operation," remains controversial. We examined the effects of acute LV reduction with the Acorn Cardiac Support Device (CSD) in dogs with HF (LV ejection fraction < 30%). METHODS: HF was produced in 15 dogs by intracoronary microembolization. In nine dogs, intravenous dobutamine was administered to reduce LV end-diastolic dimension (LVEDD) by 10%-25%. While on dobutamine infusion, the CSD, a preformed knitted polyester device, was surgically placed around the ventricles, anchored to the arteriovenous (AV) groove, and tailored anteriorly to fit snugly over the ventricles. Dogs were then weaned off dobutamine. RESULTS: On average, the procedure reduced LVEDD by 7 +/- 1 mm (range 5-12 mm). Of the nine dogs, two died before completion of the study and seven survived for the entire period. Six dogs did not undergo device placement and served as controls. All were followed for 3 months prior to sacrifice. In controls, LV end-diastolic volume increased after 3 months (66 +/- 5 mL vs 77 +/- 6 mL; p = 0.007), while in CSD-treated dogs (n = 7), it decreased (80 +/- 5 mL vs 60 +/- 3 mL; p = 0.002). In controls, LV ejection fraction (EF) decreased after 3 months (27 +/- 1% vs 23 +/- 1%; p = 0.001) but was unchanged in CSD-treated dogs (25 +/- 1% vs 26 +/- 1%; p = 0.66). Compared to controls, CSD-treated dogs showed improved LV diastolic dysfunction and chamber sphericity, decreased wall stress, and no functional mitral regurgitation (MR). CONCLUSION: In dogs with advanced HF, acute LV reduction with the Acorn CSD prevents progressive global LV dilatation and ameliorates functional MR.

Acute Disease↗