[Choice of neurostimulators for locoregional anesthesia].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to C Aveline.
Explore the source record for details and available documents.
A 72-yr-old patient was to undergo a left lumbar plexus block by the posterior approach to achieve postoperative analgesia after hip replacement. The block failed after three unsuccessful attempts to identify nerve structures and a fascia iliaca compartment block was performed. Postoperatively the patient received enoxaparin and then phenylindanedione for thromboprophylaxis. She was re-admitted 2 weeks after surgery because of a lower limb motor deficit and a left retroperitoneal haematoma requiring blood transfusion. Clinicians need to be aware of this potential complication of lumbar plexus block in patients receiving thrombphylaxis.
OBJECTIVE: To determine the effect of epidural analgesia (EA) on the duration of labour and the mode of delivery. DATA SOURCES: A Medline computerised literature research was conducted from 1989 to 2000 including all the prospective studies comparing EA and systemic analgesia during labour. DATA SYNTHESIS: EA prolongs the first and second stages of labour and increases the rate of instrumental delivery, without neonatal side effects. EA is not responsible for dystocia and caesarean section rate is not increased by this mode of analgesia. The effect of combined spinal-epidural analgesia is comparable to the one of EA on the length of labour and the mode of delivery. Ropivacaine does not appear to be different from bupivacaine in that setting. The benefit of ambulation remains controversial since it does not reduce the incidence of instrumental delivery, compared to conventional EA with similarly diluted local anaesthetic solutions. CONCLUSIONS: Pain relief provided by EA combined to modification of obstetric management (amniotomy, oxytocin) does not impair the rate of caesarean section and dystocia.
Combined spinal-epidural anesthesia (CSE) is an effective technique with rapid onset of labor analgesia. We describe two cases of excessive cephalad spread of sensory blockade without motor blockade in two parturients in spontaneous labor with CSE. The patients received sufentanil 5 microg intrathecally with 1.25 mg bupivacaine. Spinal injection produced dyspnea and extension of sensory blockade to cervical or facial level without fetal consequences. We conclude that the risk of these side-effects previously described with the 10 microg dose persists for lower sufentanil spinal doses.
Explore the source record for details and available documents.
We report a case of total spinal anaesthesia which occurred after a lumbar plexus block using a posterior approach. After total hip arthroplasty under general anaesthesia, a lumbar plexus block was performed according to Winnie's landmarks at the L4 interspace using a nerve stimulator. Aspiration test for blood and spinal fluid were both negative, as well as a test dose of 3 mL lidocaine 2%-bupivacaine 0.5%. One minute after the injection of 27 mL of the same mixture, a complete anaesthetic block occurred with hypotension and loss of consciousness requiring intubation and controlled ventilation during 3h30, without sequelae. Lumbar plexus block using a posterior approach must be performed cautiously and a slow and fractionated injection of the full dose is recommended.
Explore the source record for details and available documents.
Explore the source record for details and available documents.