PubMed Health⌕ Search

Biomedical subjects

C B McCrystal

Publications and source records attributed to C B McCrystal.

4 recordsLinked to original sources

Characterisation of water behaviour in cellulose ether polymers using low frequency dielectric spectroscopy.

The behaviour of water in hydroxypropylmethylcellulose (HPMC) K100LV, K4M, K15M, K100M, E4M, F4M and HPC polymers was characterised using low frequency dielectric spectroscopy (LFDS). Dielectric responses of 25% (w/w) HPMC K15M gels and deionised water were found to be similar at +22 and 0 degrees C. However, at -30 degrees C, a dielectric response typical of a solid was apparent. The melting of frozen water within gels was detected as increases in the magnitude of the dielectric response with increase in temperature. More than one phase transition was visible in the majority of gels studied which may be related to the presence of different states of water melting at different temperatures. In addition to polymer concentration, both polymer molecular weight and substitution level influenced the nature of the transitions. The magnitude of the dielectric response was increased in all HPMC gel systems in comparison to the response seen in deionised water. Drug addition affected the transitions occurring during the melting of ice in the gels. This may be related to the presence of ionic species in the systems. LFDS studies on cellulose ether gels have provided some interesting evidence for the existence of more than one state of water within such gel systems. The results are in good agreement with thermal analysis findings in similar gel systems.

Cellulose↗

Water distribution studies within cellulose ethers using differential scanning calorimetry. 1. Effect of polymer molecular weight and drug addition.

Differential scanning calorimetry (DSC) was employed to characterize the distribution of water in gels produced from a series of hydroxypropylmethylcelluloses (HPMC, Methocel K-series) of different molecular weights (i.e., different viscosity grades). The presence of loosely bound water was characterized as pre-endothermic events occurring at temperatures below the main melting endotherm of free water. Both the magnitude and occurrence of these pre-endothermic events were affected by polymer molecular weight and gel storage time. In addition, the amount of water bound to the polymer depended on polymer molecular weight and gel storage time. The temperature at which frozen water melted within the gels was dependent on polymer concentration, with a depression of extrapolated endothermic melting peak onset occurring with an increase in polymer concentration. The addition of propranolol hydrochloride or diclofenac sodium, as model drugs, affected both the occurrence of pre-endothermic events and the distribution of water within the gels.

Calorimetry, Differential Scanning↗

Water distribution studies within cellulose ethers using differential scanning calorimetry. 2. Effect of polymer substitution type and drug addition.

The distribution of water within gels composed of a range of cellulose ether polymers of similar molecular weights (viscosity grades of 4000-6000 cP) but varying substitution types and levels was assessed by differential scanning calorimetry (DSC). Water loosely bound to the polymer was detected as one or more events appearing at the low-temperature side of the main endotherm for the melting of free water in DSC scans. Polymer substitution types and levels, and added drugs (50 mM propranolol hydrochloride or 50 mM diclofenac sodium) influenced the appearance of these melting events. Hydroxypropylcellulose (HPC) and hydroxypropylmethylcellulose (HPMC F4M) gels showed behavior different to that of the other polymers studied. It is thought that any water binding to HPC gels is tightly attached and is not visible as pre-endothermic events on DSC scans. The amount of water bound per polymer repeating unit (PRU) was influenced by and related to the degree of hydrophilic and hydrophobic substitution on the polymer backbone and by the inclusion of either drug. HPC gels had the highest bound water content after 96 h and this was probably related to the high percentage of hydrophilic hydroxypropoxyl substitutions in this polymer. In contrast, methylcellulose (MC A4M) had the lowest bound water content after 96 h storage, and this was explained by the lack of hydrophilic hydroxypropoxyl substitutions in the polymer.

Calorimetry, Differential Scanning↗

Amsorb: a new carbon dioxide absorbent for use in anesthetic breathing systems.

BACKGROUND: This article describes a carbon dioxide absorbent for use in anesthesia. The absorbent consists of calcium hydroxide with a compatible humectant, namely, calcium chloride. The absorbent mixture does not contain sodium or potassium hydroxide but includes two setting agents (calcium sulphate and polyvinylpyrrolidine) to improve hardness and porosity. METHODS: The resultant mixture was formulated and subjected to standardized tests for hardness, porosity, and carbon dioxide absorption. Additionally, the new absorbent was exposed in vitro to sevoflurane, desflurane, isoflurane, and enflurane to determine whether these anesthetics were degraded to either compound A or carbon monoxide. The performance data and inertness of the absorbent were compared with two currently available brands of soda lime: Intersorb (Intersurgical Ltd., Berkshire, United Kingdom) and Dragersorb (Drager, Lubeck, Germany). RESULTS: The new carbon dioxide absorbent conformed to United States Pharmacopeia specifications in terms of carbon dioxide absorption, granule hardness, and porosity. When the new material was exposed to sevoflurane (2%) in oxygen at a flow rate of 1 l/min, concentrations of compound A did not increase above those found in the parent drug (1.3-3.3 ppm). In the same experiment, mean +/-SD concentrations of compound A (32.5 +/- 4.5 ppm) were observed when both traditional brands of soda lime were used. After dehydration of the traditional soda limes, immediate exposure to desflurane (60%), enflurane (2%), and isoflurane (2%) produced concentrations of carbon monoxide of 600.0 +/- 10.0 ppm, 580.0 +/- 9.8 ppm, and 620.0 +/-10.1 ppm, respectively. In contrast, concentrations of carbon monoxide were negligible (1-3 ppm) when the anhydrous new absorbent was exposed to the same anesthetics. CONCLUSIONS: The new material is an effective carbon dioxide absorbent and is chemically unreactive with sevoflurane, enflurane, isoflurane, and desflurane.

Absorption↗