PubMed Health⌕ Search

Biomedical subjects

C B Prater

Publications and source records attributed to C B Prater.

4 recordsLinked to original sources

Immobilized proteins in buffer imaged at molecular resolution by atomic force microscopy.

Samples of supported planar lipid-protein membranes and actin filaments on mica were imaged by atomic force microscopy (AFM). The samples were fully submerged in buffer at room temperature during imaging. Individual proteins bound to the reconstituted membrane were distinguishable; some structural details could be resolved. Also, surface-induced, self-assembling of actin filaments on mica could be observed. Monomeric subunits were imaged on individual actin filaments. The filaments could be manipulated on or removed from the surface by the tip of the AFM. The process of the decoupling of the filamentous network from the surface upon changing the ionic conditions was imaged in real time.

Actins↗

Imaging crystals, polymers, and processes in water with the atomic force microscope.

The atomic force microscope (AFM) can be used to image the surface of both conductors and nonconductors even if they are covered with water or aqueous solutions. An AFM was used that combines microfabricated cantilevers with a previously described optical lever system to monitor deflection. Images of mica demonstrate that atomic resolution is possible on rigid materials, thus opening the possibility of atomic-scale corrosion experiments on nonconductors. Images of polyalanine, an amino acid polymer, show the potential of the AFM for revealing the structure of molecules important in biology and medicine. Finally, a series of ten images of the polymerization of fibrin, the basic component of blood clots, illustrate the potential of the AFM for revealing subtle details of biological processes as they occur in real time.

Crystallography↗

The scanning ion-conductance microscope.

A scanning ion-conductance microscope (SICM) has been developed that can image the topography of nonconducting surfaces that are covered with electrolytes. The probe of the SICM is an electrolyte-filled micropipette. The flow of ions through the opening of the pipette is blocked at short distances between the probe and the surface, thus, limiting the ion conductance. A feedback mechanism can be used to maintain a given conductance and in turn determine the distance to the surface. The SICM can also sample and image the local ion currents above the surfaces. To illustrate its potential for imaging ion currents through channels in membranes, a topographic image of a membrane filter with 0.80-micrometer pores and an image of the ion currents flowing through such pores are presented.

Cell Membrane↗

STM and AFM images of nucleosome DNA under water.

We have imaged DNA from the calf thymus nucleosome using a scanning tunneling microscope (STM) operated in water. The fragments are deposited onto the interface between a buffer solution and an epitaxially grown gold surface using an electrochemical tecnique. Most of the fragments are fairly straight, and when individual polymers can be identified, their length is consistent with the expected 146 basepairs (approximately 500 A). The resolution is often adequate to show signs of the 36 A helical pitch. Some images show a structure which appears to have abrupt kinks of the sort predicted by Crick and Klug (Nature 255, 530-533, 1975). In order to check that this shape is not a consequence of binding to underlying structure on the gold substrate, we have also made images of kinked structures using an atomic force microscope (AFM) with the DNA bound to glass.

Animals↗